Customer: Endorfy

Fluctus 140 OS

Report Number: 25FN206A
Customer ID: 191
Lab ID: EY14000206

Test Report Results

Section A: Noise Testing Equipment

Test Environment Hemi-Anechoic Chamber with 6 dB(A) noise floor
Conditions 25(±2) degrees Celsius, 40-50% humidity
Sound Analyzer Bruel & Kjaer 2270-S G4 & 2250-L G4
Microphone Bruel & Kjaer Type 4955-A
Mic Calibrator Bruel & Kjaer Type 4231
Data Logger Picoscope TC-08
Testing Methodology Cybenetics Phi Fan Performance Standard

Section B: Fan Testing Equipment Technical Specifications

Manufacturer Long Win Science & Technology Corporation
Model Number LW-9266
Air Flow Rate 2.4 – 250 CFM
Accuracy of Air Flow Rage < 3.5% INFS
Repeatability error < 2%
Static pressure 0-20mmAq (100mmAq with the high static pressure throttle device)
Overall Dimensions 0.7 (W) x 2.2 (L) x 1.6 (H) m
Power Source 220VAC, 5A, Single Phase, 50/60Hz
Based on Standards ISO 5801-2007, AMCA 210-0, ASHRAE 51-2007, IEC 61591-2005, GB/T 1236-200

Section C: PHI Performance Levels

25dBAP Max1.15
25dBAQ Max63.26

Section D: Information about DUT

Model NameEndorfy
Serial Number10-10152401006454
Lab IDEY14000206
Comments
Date of receiptAug 27, 2025
Report Issued DateAug 29, 2025
Testing DateAug 29, 2025
Engineer Name-
Authorized By the Laboratory General ManagerAristeidis Bitziopoulos
Signature

Section E: Deviation Additions, deviations, and exceptions to the method table

Fan Performance - Static Pressure

The Fan Static Pressure Measurement’s Uncertainty is ±0.68 Pa

The reported expanded uncertainty (U) was derived as the product of the combined standard uncertainty (u) and the coverage factor k = 2, corresponding to a confidence interval of approximately 95%. Measurement uncertainty was determined in accordance with JCGM Guide 100:2008, "Guide to the Expression of Uncertainty in Measurements". The estimate of the reported uncertainty pertains to values obtained during the measurements and does not account for possible long-term changes.

Static Pressure Uncertainty Budget

Source of Uncertainty Standard Uncertainty, u(xi) (Pa)
LW-9266 Instrument Accuracy 0.260
Repeatability 0.075
Calibration 0.012
Temperature influence 0.208
Relative Combined Standard Uncertainty (RSS): 0.34
% Expanded Uncertainty U (k=2, norm): 0.68
Fan Performance - Airflow

The Fan Airflow Measurement’s Uncertainty is ±3.94 CFM

The reported expanded uncertainty (U) was derived as the product of the combined standard uncertainty (u) and the coverage factor k = 2, corresponding to a confidence interval of approximately 95%. Measurement uncertainty was determined in accordance with JCGM Guide 100:2008, "Guide to the Expression of Uncertainty in Measurements". The estimate of the reported uncertainty pertains to values obtained during the measurements and does not account for possible long-term changes.

Fan Airflow Uncertainty Budget

Source of Uncertainty Standard Uncertainty, u(xi) (CFM)
Repeatability 1.750
LW-9266 calibration 0.600
Environmental variation 0.500
Position error 0.482
Relative Combined Standard Uncertainty (RSS): 1.97
% Expanded Uncertainty U (k=2, norm): 3.94