Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

SP850

Report Number: 22PS2081A
Customer ID: 79
Lab ID: LL85002081

Test Report Results

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)89.825%91.870%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9920.970
12V Step-
5V/3.3V Step-
Standby Power Consumption0.0551W0.0995W
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Average Efficiency VSB82.273%80.895%

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)37.16dBA37.21dBA
Noise Graphs

Section D: ATX(Non-validated)

Efficiency With 10W (≤500W) or 2% (>500W) Load72.506%
Hold Up Time16.50ms
Power OK14.90ms
Power OK to DC Loss1.60ms
Test\Rail+12V5V3.3V5VSB
100ms11.7964.9843.3084.980
10ms0.000
1ms0.000
0.1ms0.000

Section E: Information about DUT

Product Identification Details
BrandLian Li
ModelSP850
OEMHelly Technology
Serial NumberG89SP850BY220700290
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)10
Rated Frequency (Hz)60-50
Rated Power (W)850
Operating Temperature (Continuous Full Load) (°C)
TypeSFX
Cable DesignFully Modular
Warranty-
Cybenetics
Dimensions (W x H x D)
Weight
Cooling92mm Double Ball Bearing Fan
(D92LH-12B)
Semi-Passive Operation
Cybenetics Testing Information
Lab IDLL85002081
Date of receiptJul 24, 2022
Testing DateOct 27, 2022
Report Issued DateOct 27, 2022
DUT NotesProblem in the APFC input X-cap under high operati
Engineer Name-
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors
ATX connector 20+4 pin (300mm) 1 1 16-20AWG No
4+4 pin EPS12V (600mm) 2 2 16AWG No
6+2 pin PCIe (400mm+125mm) 1 2 18AWG No
6+2 pin PCIe (400mm) 1 1 18AWG No
12 pin PCIe (400mm) 1 1 16AWG No
SATA (120mm+120mm+120mm+120mm) 2 8 18AWG No
4-pin Molex (120mm+120mm+120mm+120mm) 1 4 18AWG No
AC Power Cord (1390mm) - C13 coupler 1 1 18AWG -

Parts Description

General Data -
Manufacturer (OEM) Helly
PCB Type Double Sided
Primary Side -
Transient Filter 2x Y caps, 2x SMD-Y caps, 2x X caps, 2x CM chokes, 1x MOV
Inrush Protection NTC Thermistor 10D-11 (10 Ohm) &
1x Sanrise Tech SRC60R075BS (600V, 21.5A @ 125°C, Rds(on): 0.075Ohm)
Bridge Rectifier(s) 2x
APFC MOSFETs 2x Oriental Semiconductor (600V, 22.8A @ 100°C, Rds(on): 0.099Ohm)
APFC Boost Diode 1x G3S06510A (650V, 10A)
Bulk Cap(s) 1x Rubycon (420V, 550uF, 3,000h @ 105°C, MXK)
Main Switchers 2x
APFC Controller Champion CM6502UHHX
Resonant Controller Champion CM6901T6X
Topology Primary side: APFC, Half-Bridge & LLC converter
Secondary side: Synchronous Rectification & DC-DC converters
Secondary Side -
+12V MOSFETs 6x G013N04G
5V & 3.3V DC-DC Converters: 4x 3NA3R4
PWM Controller(s): ANPEC APW7159C
Filtering Capacitors Electrolytic: 2x Nippon Chemi-Con (4-10,000h @ 105°C, KY), 1x Rubycon (4-10,000h @ 105°C, YXJ)
Polymer: 22x no info
Supervisor IC Grenergy GR8313 (OVP, UVP, PG)
Fan Model Yate Loon D92LH-12B (92mm, 12V, 0.60A, Double Ball Bearing Fan)
5VSB Circuit -
Rectifier 1x 45R20S
Standby PWM Controller Excelliance MOS EM8569C

Photos
Top sidePower specifications label

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.18%
Timings ±0.48ms
Power Excursions (Transient Response) ±0.1V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dBμV
Noise Output ±1.23 dB