Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

Core Reactor II 750W

Report Number: 23PS2217A
Customer ID: 107
Lab ID: AD75002217

Test Report Results

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)89.153%91.118%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9880.960
12V Step-
5V/3.3V Step-
Standby Power Consumption0.0179W0.0791W
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Average Efficiency VSB79.219%78.292%

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)26.05dBA25.53dBA
Noise Graphs

Section D: ATX(Non-validated)

Efficiency With 10W (≤500W) or 2% (>500W) Load71.281%
Hold Up Time18.60ms
Power OK16.00ms
Power OK to DC Loss2.60ms
Test\Rail+12V5V3.3V5VSB
100ms12.0375.0723.2615.066
10ms11.9065.0543.2415.034
1ms11.8405.0423.2285.015
0.1ms11.7135.0283.2094.991

Section E: Information about DUT

Product Identification Details
BrandXPG
ModelCore Reactor II 750W
OEMChannel Well Technology
Serial Number4N1680B15032
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)10-5
Rated Frequency (Hz)47-63
Rated Power (W)750
Operating Temperature (Continuous Full Load) (°C)
TypeATX12V
Cable DesignFully Modular
Warranty
Cybenetics
Dimensions (W x H x D)
Weight
Cooling120mm Fluid Dynamic Bearing Fan
(HA1225H12F-Z)
Semi-Passive Operation
Cybenetics Testing Information
Lab IDAD75002217
Date of receiptJul 25, 2023
Testing DateJul 31, 2023
Report Issued DateAug 25, 2023
Engineer Name-
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors
ATX connector 20+4 pin (650mm) 1 1 16-20AWG No
4+4 pin EPS12V (650mm) 2 2 16AWG No
6+2 pin PCIe (650mm+150mm) 2 4 16-18AWG No
6+2 pin PCIe (650mm) 2 2 16AWG No
12+4 pin PCIe (650mm) (600W) 1 1 16-24AWG No
SATA (500mm+150mm+150mm+150mm) 2 8 18AWG No
4-pin Molex (500mm+150mm+150mm+150mm) 1 4 18AWG No
AC Power Cord (1400mm) - C13 coupler 1 1 18AWG -

Photos
Top sidePower specifications label

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.18%
Timings ±0.48ms
Power Excursions (Transient Response) ±0.1V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dBμV
Noise Output ±1.23 dB