Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

MPG A850G PCIE5

Report Number: 24PS2404A
Customer ID: 77
Lab ID: MS85002404

Test Report Results

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)88.498%90.768%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9910.965
12V Step-
5V/3.3V Step-
Standby Power Consumption0.0175W0.0802W
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Average Efficiency VSB79.208%78.322%

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)28.69dBA28.64dBA
Noise Graphs

Section D: ATX(Non-validated)

转换效率在交流电输入电压为115V且电源输出为10瓦(≤500W)或2%(>500W)负载条件的测试数据61.779%
Hold Up Time16.30ms
Power OK13.90ms
Power OK to DC Loss2.40ms
Test\Rail+12V5V3.3V5VSB
100ms11.9335.0073.2435.087
10ms11.6824.9753.1925.034
1ms11.5654.9623.1705.008
0.1ms11.4484.9463.1464.981

Section E: Information about DUT

Product Identification Details
BrandMSI
ModelMPG A850G PCIE5
OEMCWT
Serial Number
Product Specifications
Manufacturer
额定电压 (Vrms)100-240
额定电流 (Arms)10-5
额定频率 (Hz)50-60
额定功率 (W)850
Operating Temperature (Continuous Full Load) (°C)
类别ATX12V
线材设计Fully Modular
Warranty
Cybenetics
Dimensions (W x H x D)
Weight
散热135mm Fluid Dynamic Bearing Fan
(HA13525Η12SF-Z)
半被动运转✓ (selectable)
Cybenetics Testing Information
Lab IDMS85002404
Date of receiptMar 13, 2024
Testing DateApr 5, 2024
Report Issued DateApr 8, 2024
Engineer Name-
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors
ATX connector 20+4 pin (600mm) 1 1 18-22AWG No
4+4 pin EPS12V (750mm) 2 2 18AWG No
6+2 pin PCIe (600mm+150mm) 2 4 16-18AWG No
2x 6+2 pin PCIe (600mm) 1 2 16-18AWG No
12+4 pin PCIe (590mm) (600W) 1 1 16-26AWG No
SATA (500mm+150mm+150mm) 2 6 18AWG No
SATA (500mm+150mm) 1 2 18AWG No
4-pin Molex (500mm+150mm+150mm+150mm) / FDD (+150mm) 1 4 / 1 18-20AWG No

Photos
Top sidePower specifications label

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.18%
Timings ±0.48ms
Power Excursions (Transient Response) ±0.1V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dBμV
Noise Output ±1.23 dB