GX III 1050 Gold
| Electronic Loads | Chroma 63601-5 x2 Chroma 63600-2 Chroma 63640-80-80 x10 Chroma 63610-80-20 |
| AC Sources | Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500 |
| Power Analyzers | Rohde & Schwarz HMC8015 & NPA701 |
| Oscilloscopes | Picoscope 4444, Siglent SDS2104X PLUS |
| Sound Analyzer | Bruel & Kjaer 2270 G4 |
| Microphone | Bruel & Kjaer Type 4955-A |
| Temperature Logger | Picoscope TC-08 |
| Tachometer | UNI-T UT372 |
| Multimeters | Keysight 34465A |
| EMI Analyzer | TekBox TBMR-110M-EU |
| Isolation Transformer | 4kVA |
| UPS | FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA |
| Testing Methodology | Cybenetics PSU Test Protocol |
| Voltage | 115V | 230V |
|---|---|---|
| Efficiency (>1450 Load Combinations) | 89.713% | 91.874% |
| Efficiency Graphs | ![]() | ![]() |
| Average PF (>1450 Load Combinations) | 0.993 | 0.980 |
| 12V Step | - | |
| 5V/3.3V Step | - | |
| Standby Power Consumption | 0.0720W | 0.1517W |
| ErP Lot 3/6 Ready | ✓ | |
| (EU) No 617/2013 Compliance | ✓ | |
| Average Efficiency VSB | 81.141% | 81.048% |
| Voltage | 115V | 230V |
|---|---|---|
| Noise Rating (>1450 Load Combinations) | 26.75dBA | 26.73dBA |
| Noise Graphs | ![]() | ![]() |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 77.523% |
| Hold Up Time | 25.00ms |
| Power OK | 21.50ms |
| Power OK to DC Loss | 3.50ms |
| Test\Rail | +12V | 5V | 3.3V | 5VSB |
| 100ms | 11.804 | 4.900 | 3.243 | 4.931 |
| 10ms | 11.485 | 4.880 | 3.206 | 4.868 |
| 1ms | 11.344 | 4.868 | 3.183 | 4.836 |
| 0.1ms | 11.206 | 4.859 | 3.162 | 4.806 |
| Product Identification Details | |
| Brand | Cooler Master |
| Model | GX III 1050 Gold |
| OEM | Lite-On |
| Serial Number | |
| Product Specifications | |
| Manufacturer | |
| Rated Voltage (Vrms) | 100-240 |
| Rated Current (Arms) | 13-7 |
| Rated Frequency (Hz) | 50-60 |
| Rated Power (W) | 1050 |
| Operating Temperature (Continuous Full Load) (°C) | |
| Type | ATX12V |
| Cable Design | Fully Modular |
| Warranty | |
| Cybenetics | |
| Dimensions (W x H x D) | |
| Weight | |
| Cooling | 135mm Fluid Dynamic Bearing Fan (HA13525H12F-Z) |
| Semi-Passive Operation | ✓ |
| Cybenetics Testing Information | |
| Lab ID | CM10502428 |
| Date of receipt | Apr 9, 2024 |
| Testing Date | Apr 26, 2024 |
| Report Issued Date | Apr 30, 2024 |
| Engineer Name | - |
| Authorized By the Laboratory Technical Manager | Aristeidis Bitziopoulos |
| Signature | ![]() |
| Modular Cables | ||||
| Description | Cable Count | Connector Count (Total) | Gauge | In Cable Capacitors |
| ATX connector 20+4 pin (610mm) | 1 | 1 | 18-22AWG | No |
| 4+4 pin EPS12V (600mm) | 1 | 1 | 18AWG | No |
| 8 pin EPS12V (600mm) | 1 | 1 | 18AWG | No |
| 6+2 pin PCIe (550mm) | 3 | 3 | 16-18AWG | No |
| 12+4 pin PCIe (650mm) (600W) | 1 | 1 | 16-28AWG | No |
| SATA (500mm+120mm+120mm+120mm) | 3 | 12 | 18AWG | No |
| 4-pin Molex (500mm+120mm+120mm+120mm) | 1 | 4 | 18AWG | No |
| AC Power Cord (1370mm) - C13 coupler | 1 | 1 | 17AWG | - |
| Under Voltage Protection | ✓ |
| Over Power Protection | ✓ |
| Over Current (+12V) Protection | ✓ |
| Over Temperature Protection | ✓ |
| Short Circuit Protection | ✓ |
| Surge Protection | ✓ |
| Inrush Current Protection | - |
| Photos | ![]() | ![]() |
| Top side | Power specifications label |
F.1 General Statement
Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.
The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.
The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.
Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.
F.2 Expanded Measurement Uncertainty by Measurement Type
| Measurement | Expanded Uncertainty U (k=2, norm) |
| Efficiency | ±0.18% |
| Timings | ±0.48ms |
| Power Excursions (Transient Response) | ±0.1V |
| Conducted EMI Emissions (150 kHz – 30 MHz) | ±2.35 dBμV |
| Noise Output | ±1.23 dB |