Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

C850 Gold

Report Number: 24PS2451A
Customer ID: 85
Lab ID: NZ85002451

Test Results Report

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)88.749%90.910%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9870.963
12V Step-
5V/3.3V Step-
Standby Power Consumption0.0132W0.0704W
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Average Efficiency VSB82.065%80.652%

Efficiency and power factor by load rangeSupplementary calculated results – outside the scope of accreditation

8384858687888990919293Average efficiency (%)84.2389.2790.3989.6788.5185.2790.7792.4492.2991.670-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 83115V230V
8384858687888990919293Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 83115V230V
0.860.880.900.920.940.960.981.00Average power factor0.9660.9850.9890.9930.9950.8830.9600.9750.9810.9860-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.86115V230V
0.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.86115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %200 / 20084.23%85.27%0.9660.883
20-<40 %318 / 31889.27%90.77%0.9850.960
40-<60 %319 / 31990.39%92.44%0.9890.975
60-<80 %318 / 31889.67%92.29%0.9930.981
80-100 %326 / 32688.51%91.67%0.9950.986
70-100 % (High-Load)486 / 48688.81%91.83%0.9950.985
All (published average)1481 / 148188.75%90.91%0.9870.963
Info

The average efficiency and power factor in five ranges of load. Calculated from the 1481 (115V) and 1481 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 850 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)25.41dBA25.44dBA
Noise Graphs

Noise by load rangeSupplementary calculated results – outside the scope of accreditation

High-Load Index (70-100 % load)
Noise 30.2 dB(A) at 115V and 30.3 dB(A) at 230V · loudest point 37.5 dB(A)
Efficiency 88.81% / 91.83% · power factor 0.995 / 0.985 (115V / 230V)
0510152025303540Average noise (dB(A))5.05.00-<20 %fan off 100%/100%5.05.020-<40 %fan off 77%/77%5.05.040-<60 %fan off 1%/1%14.814.960-<80 %fan off 0%/0%31.931.980-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))5.05.00-<20 %off 100%/100%5.05.020-<40 %off 77%/77%5.05.040-<60 %off 1%/1%14.814.960-<80 %off 0%/0%31.931.980-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %5.0 (5.0)5.0 (5.0)100% / 100%
20-<40 %5.0 (5.0)5.0 (5.0)77% / 77%
40-<60 %5.0 (5.0)5.0 (5.0)1% / 1%
60-<80 %14.8 (21.8)14.9 (21.8)0% / 0%
80-100 %31.9 (37.5)31.9 (37.5)0% / 0%
70-100 % (High-Load)30.2 (37.5)30.3 (37.5)0% / 0%
All (published average)25.4 (37.5)25.5 (37.5)30% / 30%
Info

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1481 (115V) and 1481 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 850 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)Supplementary calculated results – outside the scope of accreditation

115V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 44.3 °C0 RPM · <6.0 dB(A) · 44.3 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 45.5 °C0 RPM · <6.0 dB(A) · 45.5 °Cfan off in both
50%409 RPM · <6.0 dB(A) · 42.1 °C409 RPM · <6.0 dB(A) · 42.1 °C<6.0 in both
100%1248 RPM · 36.1 dB(A) · 45.7 °C1248 RPM · 36.1 dB(A) · 45.7 °C+0.0 dB(A)
230V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 44.4 °C0 RPM · <6.0 dB(A) · 44.4 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 45.4 °C0 RPM · <6.0 dB(A) · 45.4 °Cfan off in both
50%413 RPM · <6.0 dB(A) · 42.3 °C413 RPM · <6.0 dB(A) · 42.3 °C<6.0 in both
100%1249 RPM · 36.1 dB(A) · 45.6 °C1249 RPM · 36.1 dB(A) · 45.6 °C+0.0 dB(A)
Info

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load77.025%
Hold Up Time25.60ms
Power OK24.20ms
Power OK to DC Loss1.40ms
Test\Rail+12V5V3.3V5VSB
100ms11.9845.0373.3094.968
10ms11.8105.0133.2784.927
1ms11.7215.0013.2604.906
0.1ms11.5804.9833.2334.876

Section E: Information about DUT

Product Identification Details
BrandNZXT
ModelC850 Gold
OEM/ODMChannel Well Technology
Serial Number52241Z06500003
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)10
Rated Frequency (Hz)50-60
Rated Power (W)850
Operating Temperature (Continuous Full Load) (°C)
TypeATX12V
Cable DesignFully Modular
Warranty-
Cybenetics
Dimensions (W x H x D)
Weight
Cooling135mm Fluid Dynamic Bearing Fan
(HA13525H12SF-Z)
Semi-Passive Operation✓ (selectable)
Cybenetics Testing Information
Lab IDNZ85002451
Date of receiptMay 7, 2024
Testing DateMay 21, 2024
Report Issued DateMay 22, 2024
Engineer Name-
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors
ATX connector 20+4 pin (600mm) 1 1 16-20AWG No
4+4 pin EPS12V (700mm) 1 1 16AWG No
8 pin EPS12V (700mm) 1 1 16AWG No
6+2 pin PCIe (650mm) 3 3 16-18AWG No
12+4 pin PCIe (645mm) (600W) 1 1 16-24AWG No
SATA (500mm+145mm+145mm+145mm) 3 12 18AWG No
4-pin Molex (500mm+145mm+145mm+145mm) 1 4 18AWG No
AC Power Cord (1415mm) - C13 coupler 1 1 14AWG -

Protection Features(Non-accredited measurements)

Over Power Protection✓
Over Current (+12V) Protection✓
Over Temperature Protection✓
Short Circuit Protection✓
Surge Protection✓
Inrush Current Protection✓
Fan Failure Protection✓

Photos

Top side
Top side
Power specifications label
Power specifications label

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.43%
Timings ±2.64ms
Power Excursions (Transient Response) ±0.18V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dB
Noise Output ±1.23 dB