Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

MPG A1250GS PCIE5

Report Number: 25PS3023A
Customer ID: 77
Lab ID: MS12503023

Test Report Results

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)89.065%91.034%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9900.978
12V Step-
5V/3.3V Step-
Standby Power Consumption0.0149W0.0787W
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Average Efficiency VSB82.210%81.228%

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)20.88dBA20.83dBA
Noise Graphs

Section D: ATX(Non-validated)

Efficiency With 10W (≤500W) or 2% (>500W) Load76.547%
Hold Up Time26.80ms
Power OK22.80ms
Power OK to DC Loss4.00ms
Test\Rail+12V5V3.3V5VSB
100ms11.8474.9913.3164.956
10ms11.3914.9353.2604.912
1ms11.2214.9083.2374.892
0.1ms11.0774.8843.2144.873

Section E: Information about DUT

Product Identification Details
BrandMSI
ModelMPG A1250GS PCIE5
OEMCWT
Serial Number-
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)15
Rated Frequency (Hz)50-60
Rated Power (W)1250
Operating Temperature (Continuous Full Load) (°C)0 - 50
TypeATX12V
Cable DesignFully Modular
Warranty10 Years
Cybenetics
Dimensions (W x H x D)150 x 85 x 150mm
Weight1.76 kg (3.88 lb)
Cooling135mm Fluid Dynamic Bearing Fan (ZFF132512H)
Semi-Passive Operation✓ (selectable)
Cybenetics Testing Information
Lab IDMS12503023
Date of receiptOct 23, 2025
Testing DateNov 5, 2025
Report Issued DateNov 5, 2025
Engineer NameGeorgios Theodoros Sarimpalas
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Modular Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 24 pin (600mm) 1 1 16-20AWG Tinned Copper
4+4 pin EPS12V (750mm) 2 2 18AWG Tinned Copper
6+2 pin PCIe (600mm) 1 1 16AWG Tinned Copper
12+4 pin PCIe (600mm) (600W) 2 2 16-24AWG Tinned Copper
SATA (500mm+150mm+150mm+150mm) 2 8 18AWG Tinned Copper
4-pin Molex (500mm+150mm+150mm+150mm) 1 4 18AWG Tinned Copper
AC Power Cord (1390mm) - C13 coupler 1 1 18AWG -

Protection Features(Non-accredited measurements)

Over Voltage Protection
Under Voltage Protection
Over Power Protection
Over Current (+12V) Protection
Over Temperature Protection
Short Circuit Protection
Surge Protection

Photos
Top sidePower specifications label

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.18%
Timings ±0.48ms
Power Excursions (Transient Response) ±0.1V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dBμV
Noise Output ±1.23 dB