Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

SU2500

Report Number: 26PS3220A
Customer ID: 162
Lab ID: PL25003220

Test Results Report

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage230V
Efficiency (>1450 Load Combinations)93.297%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.969
12V Step24.00W
5V/3.3V Step3.00W
Standby Power Consumption0.1449W
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Average Efficiency VSB84.410%

Efficiency and power factor by load rangeSupplementary calculated results – outside the scope of accreditation

8889909192939495Average efficiency (%)89.7394.6094.7694.0492.890-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 88230V
8889909192939495Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 88230V
0.860.880.900.920.940.960.981.00Average power factor0.8960.9780.9850.9870.9900-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.86230V
0.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.86230V
Load rangePointsEfficiency
230V
PF
230V
0-<20 %28089.73%0.896
20-<40 %32494.60%0.978
40-<60 %32494.76%0.985
60-<80 %32094.04%0.987
80-100 %32792.89%0.990
70-100 % (High-Load)48693.19%0.989
All (published average)157593.30%0.969
Info

The average efficiency and power factor in five ranges of load. Calculated from the 1575 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 2500 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Section C: LAMBDA

Voltage230V
Noise Rating (>1450 Load Combinations)47.02dBA
Noise Graphs

Noise by load rangeSupplementary calculated results – outside the scope of accreditation

High-Load Index (70-100 % load)
Noise 51.9 dB(A) at 230V · loudest point 55.3 dB(A)
Efficiency 93.19% · power factor 0.989 (230V)
051015202530354045505560Average noise (dB(A))15.90-<20 %fan off 64%22.520-<40 %fan off 0%35.240-<60 %fan off 0%46.460-<80 %fan off 0%53.080-100 %fan off 0%230V
0102030405060Average noise (dB(A))15.90-<20 %off 64%22.520-<40 %off 0%35.240-<60 %off 0%46.460-<80 %off 0%53.080-100 %off 0%230V
Load rangeNoise 230V
avg (loudest)
Fan off
230V
0-<20 %15.9 (21.9)64%
20-<40 %22.5 (28.5)0%
40-<60 %35.2 (41.8)0%
60-<80 %46.4 (50.4)0%
80-100 %53.0 (55.3)0%
70-100 % (High-Load)51.9 (55.3)0%
All (published average)47.1 (55.3)11%
Info

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1575 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 2500 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)Supplementary calculated results – outside the scope of accreditation

230V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%0 RPM · <6.0 dB(A) · 31.9 °C0 RPM · <6.0 dB(A) · 44.2 °Cfan off in both
20%0 RPM · <6.0 dB(A) · 33.9 °C679 RPM · 23.1 dB(A) · 40.7 °Cfan starts (<6.0 → 23.1)
50%886 RPM · 29.5 dB(A) · 30.1 °C1390 RPM · 41.6 dB(A) · 42.3 °C+12.1 dB(A)
100%1750 RPM · 47.6 dB(A) · 30.2 °C2399 RPM · 56.0 dB(A) · 46.0 °C+8.4 dB(A)
Info

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load-
Hold Up Time17.80ms
Power OK15.10ms
Power OK to DC Loss2.70ms
Test\Rail+12V5V3.3V5VSB
100ms11.9814.9573.2494.972
10ms11.8454.9423.2324.963
1ms11.7724.9323.2174.956
0.1ms11.6604.9203.2144.946

Section E: Information about DUT

Product Identification Details
BrandCPS PCCooler
ModelSU2500
OEM/ODMCE-Link
Serial Number-
Product Specifications
Manufacturer
Rated Voltage (Vrms)200-240
Rated Current (Arms)11-15
Rated Frequency (Hz)50-60
Rated Power (W)2500
Operating Temperature (Continuous Full Load) (°C)10 - 44
TypeATX12V
Cable DesignFully Modular
WarrantyNo Info
Cybenetics
Dimensions (W x H x D)150 x 85 x 165mm
Weight2.56 kg (5.64 lb)
Cooling135mm Double Ball Bearing Fan (HA13525H12B-Z)
Semi-Passive Operation✓ (selectable)
Cybenetics Testing Information
Lab IDPL25003220
Date of receiptFeb 17, 2026
Testing DateMar 30, 2026
Report Issued DateApr 17, 2026
DUT Notes• Hold-up time re-checked on 2026-11-02: the lowest hold-up of all captures was logged (17.80 ms; AC loss to PWR_OK 15.10 ms; PWR_OK inactive to DC loss 2.70 ms).
Engineer NameGeorgios Theodoros Sarimpalas
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Modular Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 20+4 pin (600mm) 1 1 16-22AWG Tinned Copper
4+4 pin EPS12V (750mm) 2 2 18AWG Tinned Copper
6+2 pin PCIe (600mm) 6 6 16-18AWG Tinned Copper
12+4 pin PCIe (600mm) (600W) 4 4 16-24AWG Tinned Copper
SATA (590mm+150mm+150mm) 3 9 18AWG Tinned Copper
SATA (590mm+150mm) / 4-pin Molex (+150mm) 2 4 / 2 18AWG Tinned Copper

Protection Features(Non-accredited measurements)

Over Power Protection✓
Over Current (+12V) Protection✓
Over Temperature Protection✓
Short Circuit Protection✓
Surge Protection✓
Inrush Current Protection✓
Fan Failure Protection✗

Parts Description

General Data
Manufacturer (OEM) CE-Link
PCB Type Double-Sided
Primary Side
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV
Inrush Protection NTC Thermistor MF72 5-D15 (5 Ohm @ 25°C) & Relay
Bridge Rectifier 12x Nexperia GS10M (1000V, 10A @ 100°C)
APFC MOSFETs 4x Shenzhen Xinliwei Electronics XLW C80R055Y (650V, 80A @ 25°C, Rds(on): 0.055 Ohm)
APFC Boost Diode 2x Global Power Technology G4S06515AT (650V, 15A @ 143°C )
Bulk Cap(s) 1x Nippon Chemi-con (420V, 1150uF, 2000h @ 105°C, KHE )
1x Nippon Chemi-con (400V, 820uF, 2000h @ 105°C, KMW )
Main Switchers 4x Reactor Micro RMC60R068FD (600V, 48A @ 25°C, Rds(on): 0.068 Ohm)

APFC Controller

Champion CM6500UNX &
Champion CM03AX (reducing no load consumption)

Resonant Controller Champion CM6901T6X
IC Driver 2x Novosense Microelectronics  NSi6602BD
Topology Primary side: APFC, Full-Bridge & LLC Resonant Converter
Secondary side: [12V] Synchronous Rectification & [Minor Rails] DC-DC converters
Secondary Side
+12V MOSFETs 16x Infineon BSC010N04LS (40V, 178A @ 100°C, Rds(on): 1.0 mOhm)
5V & 3.3V DC-DC Converters: Vergiga Semiconductor VSP007N04MS-G (40V, 50A @ 100°C, Rds(on): 4.3 mOhm)
PWM Controller(s): Anpec APW7159C
Filtering Capacitors

Electrolytic:
6x Nichicon (10.000h @ 105°C, HW)
1x Rubycon (4~10.000h @ 105°C, YXJ )
1x Rubycon (4~10.000h @ 105°C, YXF )
1x Nippon Chemi-con (5~6.000h @ 105°C, KZH )
Polymer:
26x Nippon Chemi-con, 46x TEAPO

Supervisor IC Grenergy GR8329E (OVP, UVP, OCP, PG)
Fan Controller / Micro Controller Unisonic Technologies UTC393
Fan Model Hong Hua HA13525H12B-Z (135mm, 12V, 0.50A, Double Ball Bearing Fan)
5VSB Circuit
Rectifier Infineon BSC0702LS (60V, 2.7mOhm)
Standby PWM Controller Meraki Integrated MK2787

Photos

Top side
Top side
Power specifications label
Power specifications label
PSU Internals
PSU Internals
Fan
Fan

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.43%
Timings ±2.64ms
Power Excursions (Transient Response) ±0.18V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dB
Noise Output ±1.23 dB