Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

TUF Gaming EVO 1200W

Report Number: 26PS3380A
Customer ID: 124
Lab ID: AS12003380

Test Results Report

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)89.381%91.438%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9890.944
12V Step12.00W
5V/3.3V Step2.50W
Standby Power Consumption0.0383W0.0951W
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Average Efficiency VSB79.886%79.377%
Conducted Emissions EN 55032 & CISPR 32 (48W)Passed

Efficiency and power factor by load rangeSupplementary calculated results – outside the scope of accreditation

84858687888990919293Average efficiency (%)85.6990.9591.0189.9088.4186.6792.2992.9192.4591.580-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 84115V230V
84858687888990919293Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 84115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0.9700.9900.9910.9950.9970.8400.9390.9620.9720.9770-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
0.820.840.860.880.900.920.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.82115V230V
Load rangePointsEfficiency
115V
Efficiency
230V
PF
115V
PF
230V
0-<20 %229 / 22885.69%86.67%0.9700.840
20-<40 %310 / 31190.95%92.29%0.9900.939
40-<60 %310 / 30991.01%92.91%0.9910.962
60-<80 %310 / 31189.90%92.45%0.9950.972
80-100 %315 / 31588.41%91.58%0.9970.977
70-100 % (High-Load)470 / 47188.78%91.81%0.9960.976
All (published average)1474 / 147489.38%91.44%0.9890.944
Info

The average efficiency and power factor in five ranges of load. Calculated from the 1474 (115V) and 1474 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages. 1 at 230V load combination has no valid efficiency reading (zero, or above the possible maximum) and is left out of that average.

Informational. Not part of the ETA or LAMBDA rating.

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)25.47dBA25.89dBA
Noise Graphs

Noise by load rangeSupplementary calculated results – outside the scope of accreditation

High-Load Index (70-100 % load)
Noise 30.4 dB(A) at 115V and 30.8 dB(A) at 230V · loudest point 39.6 dB(A)
Efficiency 88.78% / 91.81% · power factor 0.996 / 0.976 (115V / 230V)
0510152025303540Average noise (dB(A))<6.0<6.00-<20 %fan off 0%/0%<6.0<6.020-<40 %fan off 0%/0%<6.0<6.040-<60 %fan off 0%/0%12.312.160-<80 %fan off 0%/0%32.132.580-100 %fan off 0%/0%115V230V
010203040Average noise (dB(A))<6.0<6.00-<20 %off 0%/0%<6.0<6.020-<40 %off 0%/0%<6.0<6.040-<60 %off 0%/0%12.312.160-<80 %off 0%/0%32.132.580-100 %off 0%/0%115V230V
Load rangeNoise 115V
avg (loudest)
Noise 230V
avg (loudest)
Fan off
115V / 230V
0-<20 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
20-<40 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
40-<60 %<6.0 (<6.0)<6.0 (<6.0)0% / 0%
60-<80 %12.3 (23.8)12.1 (23.8)0% / 0%
80-100 %32.1 (39.6)32.5 (39.6)0% / 0%
70-100 % (High-Load)30.4 (39.6)30.8 (39.6)0% / 0%
All (published average)25.5 (39.6)25.9 (39.6)0% / 0%
Info

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1474 (115V) and 1474 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1200 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature". Below 6 dB(A), the floor of our sound meter, the table and the chart show <6.0. In the averages a stopped fan counts as 5 dB(A), as in the published average.

Informational. Not part of the ETA or LAMBDA rating.

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load66.602%
Hold Up Time19.60ms
Power OK16.90ms
Power OK to DC Loss2.70ms
Test\Rail+12V5V3.3V5VSB
100ms11.9895.0003.2495.021
10ms11.6074.9423.1804.983
1ms11.4684.9193.1534.970
0.1ms11.6764.9363.1794.981

Section E: Information about DUT

Product Identification Details
BrandASUS
ModelTUF Gaming EVO 1200W
OEM/ODMSeasonic
Serial Number-
Product Specifications
Manufacturer
Rated Voltage (Vrms)100-240
Rated Current (Arms)7.5-15
Rated Frequency (Hz)50-60
Rated Power (W)1200
Operating Temperature (Continuous Full Load) (°C)0 - 50
TypeATX12V
Cable DesignFully Modular
Warranty8 years
Cybenetics
Dimensions (W x H x D)150 x 85 x 150mm
Weight1.90 kg (4.19 lb)
Cooling135mm Double Ball Bearing Fan (CF1325H12D)
Semi-Passive Operation✗
Cybenetics Testing Information
Lab IDAS12003380
Date of receiptJul 21, 2026
Testing DateAug 3, 2026
Report Issued DateAug 7, 2026
Engineer NameEfstathios Papadopoulos
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Modular Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 20+4 pin (610mm) 1 1 18AWG Tinned Copper
4+4 pin EPS12V (750mm) 2 2 18AWG Tinned Copper
6+2 pin PCIe (500mm) 3 3 18AWG Tinned Copper
12+4 pin PCIe (500mm) (600W) 1 1 16-24AWG Tinned Copper
SATA (415mm+170mm+170mm) 2 6 18AWG Tinned Copper
4-pin Molex (415mm+170mm+170mm) 1 3 18AWG Tinned Copper

Protection Features(Non-accredited measurements)

Under Voltage Protection✓
Over Power Protection✓
Over Current (+12V) Protection✓
Over Temperature Protection✓
Short Circuit Protection✓
Surge Protection✓
Inrush Current Protection✓
Fan Failure Protection✓

Parts Description

General Data
Manufacturer (OEM)

SEASONIC

PCB Type Double-Sided
Primary Side
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV
Inrush Protection Thinking Electronic Industrial (5.5 Ohm @ 25°C) & Relay
Bridge Rectifier 2x Diodes GBU2510 (1000V, 25A @ 25°C)
APFC MOSFETs 2x Infineon IPP60R060P7 (650V, 30A @ 100°C, Rds(on): 0.115Ohm)
APFC Boost Diode Infineon IDK10G65C5 (650V, 10A @ 155°C)
Bulk Cap(s) 1x Elite (470V, 470uF, 2000h @ 105°C, PL )
1x Elite (420V, 560uF, 2000h @ 105°C, PL )
Main Switchers 4x Champion CMS60R125D (600V, ~30A @ 100°C, Rds(on): 0.125Ohm)

APFC Controller

Onsemi NCP1654

Resonant Controller Champion CM6901
Topology Primary side: APFC, Full-Bridge & LLC Resonant Converter
Secondary side: [12V] Synchronous Rectification & [Minor Rails] DC-DC converters
Secondary Side
+12V MOSFETs 8x Champion CMR013N045MS (45V, @ 100°C, Rds(on): 1.3mOhm)
5V & 3.3V DC-DC Converters: 4x uPI Group QN3106M6N (30V, 57A @ 100°C, Rds(on): 3.8mOhm)
PWM Controller(s): 1x Anpec APW7159C
Filtering Capacitors

Electrolytic:
9x Elite ( 2000~5000h @ 105°C, ED )
3x Elite ( 3000~6000h @ 105°C, EV )
Polymer:
35x Elite

Supervisor IC Weltrend WT7527RA
MCU Nuvoton M031FB0AE
Fan Model Champion CF1325H12D (135mm, 12V, 0.6A, Double Ball Bearing)
5VSB Circuit
Rectifier Dongke DK45R10S
Standby PWM Controller ExcellianceMOS  EM8569C

Photos

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.43%
Timings ±2.64ms
Power Excursions (Transient Response) ±0.18V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dB
Noise Output ±1.23 dB