HX1000i Shift Crystal (ATXv3.1)
| Electronic Loads | Chroma 63601-5 x2 Chroma 63600-2 Chroma 63640-80-80 x10 Chroma 63610-80-20 |
| AC Sources | Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500 |
| Power Analyzers | Rohde & Schwarz HMC8015 & NPA701 |
| Oscilloscopes | Picoscope 4444, Siglent SDS2104X PLUS |
| Sound Analyzer | Bruel & Kjaer 2270 G4 |
| Microphone | Bruel & Kjaer Type 4955-A |
| Temperature Logger | Picoscope TC-08 |
| Tachometer | UNI-T UT372 |
| Multimeters | Keysight 34465A |
| EMI Analyzer | TekBox TBMR-110M-EU |
| Isolation Transformer | 4kVA |
| UPS | FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA |
| Testing Methodology | Cybenetics PSU Test Protocol |
| Voltage | 115V | 230V |
|---|---|---|
| Efficiency (>1450 Load Combinations) | 89.843% | 91.222% |
| Efficiency Graphs | ||
| Average PF (>1450 Load Combinations) | 0.989 | 0.969 |
| 12V Step | 9.00W | |
| 5V/3.3V Step | 3.00W | |
| Standby Power Consumption | 0.0339W | 0.0718W |
| ErP Lot 3/6 Ready | ✓ | |
| (EU) No 617/2013 Compliance | ✓ | |
| Average Efficiency VSB | 82.328% | 81.302% |
| Conducted Emissions EN 55032 & CISPR 32 (48W) | Passed | |
Conducted Emissions Graphs ![]() ![]() | ||
| Load range | Points | Efficiency 115V | Efficiency 230V | PF 115V | PF 230V |
|---|---|---|---|---|---|
| 0-<20 % | 205 / 205 | 85.81% | 86.52% | 0.944 | 0.860 |
| 20-<40 % | 350 / 350 | 90.91% | 91.56% | 0.995 | 0.968 |
| 40-<60 % | 343 / 343 | 91.28% | 92.27% | 0.996 | 0.988 |
| 60-<80 % | 341 / 341 | 90.23% | 92.16% | 0.996 | 0.992 |
| 80-100 % | 351 / 351 | 89.36% | 91.69% | 0.996 | 0.993 |
| 70-100 % (High-Load) | 519 / 519 | 89.57% | 91.81% | 0.996 | 0.993 |
| All (published average) | 1590 / 1590 | 89.84% | 91.22% | 0.989 | 0.969 |
The average efficiency and power factor in five ranges of load. Calculated from the 1590 (115V) and 1590 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.
Informational. Not part of the ETA or LAMBDA rating.
| Voltage | 115V | 230V |
|---|---|---|
| Noise Rating (>1450 Load Combinations) | 17.00dBA | 17.12dBA |
| Noise Graphs | ||
| Load range | Noise 115V avg (loudest) | Noise 230V avg (loudest) | Fan off 115V / 230V |
|---|---|---|---|
| 0-<20 % | 5.0 (5.0) | 5.0 (5.0) | 7% / 8% |
| 20-<40 % | 5.0 (5.0) | 5.0 (5.0) | 1% / 1% |
| 40-<60 % | 5.0 (5.0) | 5.0 (5.0) | 0% / 0% |
| 60-<80 % | 7.1 (24.0) | 7.1 (21.9) | 0% / 0% |
| 80-100 % | 23.3 (29.3) | 23.4 (29.3) | 0% / 0% |
| 70-100 % (High-Load) | 21.7 (29.3) | 21.8 (29.3) | 0% / 0% |
| All (published average) | 17.0 (29.3) | 17.1 (29.3) | 1% / 1% |
The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1590 (115V) and 1590 (230V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 1000 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 41.1 °C | 0 RPM · <6.0 dB(A) · 53.4 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 44.0 °C | 0 RPM · <6.0 dB(A) · 54.2 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 48.1 °C | 0 RPM · <6.0 dB(A) · 61.7 °C | fan off in both |
| 100% | 902 RPM · 28.1 dB(A) · 30.6 °C | 916 RPM · 28.1 dB(A) · 45.3 °C | +0.0 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 36.4 °C | 0 RPM · <6.0 dB(A) · 49.0 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 42.8 °C | 0 RPM · <6.0 dB(A) · 50.4 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 51.6 °C | 0 RPM · <6.0 dB(A) · 60.6 °C | fan off in both |
| 100% | 908 RPM · 28.1 dB(A) · 30.6 °C | 1141 RPM · 34.9 dB(A) · 45.3 °C | +6.8 dB(A) |
Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.
Informational. Not part of the ETA or LAMBDA rating.
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 66.613% |
| Hold Up Time | 20.40ms |
| Power OK | 16.30ms |
| Power OK to DC Loss | 4.10ms |
| Test\Rail | +12V | 5V | 3.3V | 5VSB |
| 100ms | 11.949 | 5.049 | 3.345 | 4.925 |
| 10ms | 11.526 | 4.994 | 3.266 | 4.859 |
| 1ms | 11.394 | 4.973 | 3.236 | 4.837 |
| 0.1ms | 11.260 | 4.958 | 3.215 | 4.815 |
| Product Identification Details | |
| Brand | Corsair |
| Model | HX1000i Shift Crystal (ATXv3.1) |
| OEM/ODM | CWT |
| Serial Number | ABXMB616003LOR |
| Product Specifications | |
| Manufacturer | |
| Rated Voltage (Vrms) | 100-240 |
| Rated Current (Arms) | 6.5-13 |
| Rated Frequency (Hz) | 47-63 |
| Rated Power (W) | 1000 |
| Operating Temperature (Continuous Full Load) (°C) | 0 - 50 |
| Type | ATX12V |
| Cable Design | Fully Modular |
| Warranty | 10 years |
| Cybenetics | |
| Dimensions (W x H x D) | 150 x 87 x 200mm |
| Weight | 2.00 kg (4.40 lb) |
| Cooling | 140mm Magnetic Dome (NR140HL-RGB) |
| Semi-Passive Operation | ✓ |
| Cybenetics Testing Information | |
| Lab ID | CR10003387 |
| Date of receipt | Jul 27, 2026 |
| Testing Date | Aug 7, 2026 |
| Report Issued Date | Aug 12, 2026 |
| DUT Notes | Model: RPS0242 OCP per pin test – 12V-2x6 connector - At 9.90 A, the PSU shut down after about 20 seconds. - At 18 A, the PSU shut down immediately. - Result: works as expected (delayed trip at low overload, instant trip at high overload). |
| Engineer Name | Efstathios Papadopoulos |
| Authorized By the Laboratory Technical Manager | Aristeidis Bitziopoulos |
| Signature | ![]() |
| Modular Cables | ||||
| Description | Cable Count | Connector Count (Total) | Gauge | Cable Type |
| ATX connector 20+4 pin (610mm) | 1 | 1 | 16-20AWG | Tinned Copper |
| 4+4 pin EPS12V (650mm) | 2 | 2 | 18AWG | Tinned Copper |
| 6+2 pin PCIe (650mm) | 2 | 2 | 18AWG | Tinned Copper |
| 2x 6+2 pin PCIe (640mm) | 1 | 2 | 18AWG | Tinned Copper |
| 12+2 pin PCIe (640mm) (600W) | 1 | 1 | 16-24AWG | Tinned Copper |
| SATA (450mm+115mm+115mm+115mm) | 2 | 8 | 18AWG | Tinned Copper |
| 4-pin Molex (445mm+100mm+100mm+100mm) | 2 | 8 | 18AWG | Tinned Copper |
| AC Power Cord (1400mm) - C13 coupler | 1 | 1 | 16AWG | - |
| iCUE LINK cable (2x 90 deg. connector) (135mm) | 1 | 1 | - | - |
| iCUE LINK cable (straight to 90 deg. connector) (600mm) | 1 | 1 | - | - |
| USB 2.0 (520mm) | 1 | 1 | - | - |
| Over Power Protection | ✓ |
| Over Current (+12V) Protection | ✓ |
| Over Temperature Protection | ✓ |
| Short Circuit Protection | ✓ |
| Surge Protection | ✓ |
| Inrush Current Protection | ✓ |
| Fan Failure Protection | ✗ |
| General Data | |
| Manufacturer (OEM) | CWT |
| PCB Type | Double-Sided |
| Primary Side | |
| Transient Filter | 4x Y caps, 3x X caps, 2x CM chokes, 1x MOV |
| Inrush Protection | NTC Thermistor SCK20150 (15 Ohm @ 25°C) & Relay |
| Bridge Rectifier | 2x Vishay LVB2560 (600V, 25A @ 105°C) |
| APFC MOSFETs | 2x Infineon IPW60R099P6 (600V, 24A @ 100°C, Rds(on): 0.099Ohm) |
| APFC Boost Diode | 2x Infineon IDH08G65C6 (650V, 8A @ 145°C) |
| Bulk Cap(s) | 1x Corsair (Elite) (420V, 560uF, 2000h @ 105°C, PL ) |
| Main Switchers | 2x Infineon IPW60R099P6 (600V, 24A @ 100°C, Rds(on): 0.099Ohm) |
APFC Controller | 2x Texas Instrument UCD3138ARJAR |
| IC Driver | Silicon Labs Si8233BD |
| Topology | Primary side: APFC, Half-Bridge & LLC Resonant Converter Secondary side: [12V] Synchronous Rectification & [Minor Rails] DC-DC converters |
| Secondary Side | |
| +12V MOSFETs | 10x Infineon BSC014N04LS (40V, 145A @ 100°C, Rds(on): 1.4mOhm) |
| 5V & 3.3V | DC-DC Converters: 6x UBIQ Semi QN3107M6N (30V, 70A @ 100°C, Rds(on): 2.6mOhm) PWM Controller(s): UPI-Semi uP3861PSAF |
| Filtering Capacitors | Electrolytic: |
| Fan Controller / Micro Controller | NXP Semiconductors LPC5528 / Nuvoton M252SD2AE |
| Fan Model | Corsair NR140HL-RGB (140mm, 12V, 0.55A, Rifle Bearing with Half Domed Shaft Magnet) |
| 5VSB Circuit | |
| Rectifier | Leadtrend LD8926AA1GS (100V, 25A) |
| Standby PWM Controller | On-Bright OB2365T |




F.1 General Statement
Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.
The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.
The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.
Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.
F.2 Expanded Measurement Uncertainty by Measurement Type
| Measurement | Expanded Uncertainty U (k=2, norm) |
| Efficiency | ±0.43% |
| Timings | ±2.64ms |
| Power Excursions (Transient Response) | ±0.18V |
| Conducted EMI Emissions (150 kHz – 30 MHz) | ±2.35 dB |
| Noise Output | ±1.23 dB |