Customer: Cybenetics LTD
Syrou 6, Latsia, 2231, Nicosia Cyprus

COREMAX 500W BRONZE

Report Number: 26PS3398A
Customer ID: 140
Lab ID: AB50003398

Test Results Report

Section A: Testing Equipment

Electronic Loads Chroma 63601-5 x2
Chroma 63600-2
Chroma 63640-80-80 x10
Chroma 63610-80-20
AC Sources Chroma 6530, APM SP300VAC4000W-P, GW Instek ASR-3500
Power Analyzers Rohde & Schwarz HMC8015 & NPA701
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
EMI Analyzer TekBox TBMR-110M-EU
Isolation Transformer 4kVA
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V
Efficiency (>1450 Load Combinations)83.652%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.977
12V Step4.00W
5V/3.3V Step2.50W
Standby Power Consumption0.0702W
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Average Efficiency VSB79.685%
Conducted Emissions EN 55032 & CISPR 32 (48W)Passed

Efficiency and power factor by load rangeSupplementary calculated results – outside the scope of accreditation

7576777879808182838485Average efficiency (%)76.8682.9584.8384.9184.190-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 75115V
7576777879808182838485Average efficiency (%)0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 75115V
0.940.960.981.00Average power factor0.9630.9740.9760.9800.9830-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.94115V
0.940.960.981.00Average power factor0-<20 %20-<40 %40-<60 %60-<80 %80-100 %axis starts at 0.94115V
Load rangePointsEfficiency
115V
PF
115V
0-<20 %13276.86%0.963
20-<40 %37082.95%0.974
40-<60 %38984.83%0.976
60-<80 %38684.91%0.980
80-100 %40384.19%0.983
70-100 % (High-Load)59684.39%0.982
All (published average)168083.65%0.977
Info

The average efficiency and power factor in five ranges of load. Calculated from the 1680 (115V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 500 W. These are plain averages of the valid readings, as for the ETA rating, so the ranges combined give back the published averages.

Informational. Not part of the ETA or LAMBDA rating.

Section C: LAMBDA

Voltage115V
Noise Rating (>1450 Load Combinations)42.77dBA
Noise Graphs

Noise by load rangeSupplementary calculated results – outside the scope of accreditation

High-Load Index (70-100 % load)
Noise 45.8 dB(A) at 115V · loudest point 45.8 dB(A)
Efficiency 84.39% · power factor 0.982 (115V)
0510152025303540455055Average noise (dB(A))27.90-<20 %fan off 0%32.520-<40 %fan off 0%39.940-<60 %fan off 0%44.960-<80 %fan off 0%45.880-100 %fan off 0%115V
01020304050Average noise (dB(A))27.90-<20 %off 0%32.520-<40 %off 0%39.940-<60 %off 0%44.960-<80 %off 0%45.880-100 %off 0%115V
Load rangeNoise 115V
avg (loudest)
Fan off
115V
0-<20 %27.9 (37.8)0%
20-<40 %32.5 (42.2)0%
40-<60 %39.9 (45.8)0%
60-<80 %44.9 (45.8)0%
80-100 %45.8 (45.8)0%
70-100 % (High-Load)45.8 (45.8)0%
All (published average)42.8 (45.8)0%
Info

The average noise in five ranges of load, the share of points with the fan stopped (semi-passive operation), and the High-Load Index: the same figures for all points at 70 % of the rated output and above. Calculated from the 1680 (115V) load combinations of the certification sweep, the same data that ETA and LAMBDA use (test 0 excluded). Load is the total DC output as a share of the rated 500 W. Noise is averaged on the energy scale, as for LAMBDA, so the ranges combined give back the published average noise. Each load combination is held for about five seconds; the stabilized readings at fixed loads are under "Noise under high ambient temperature".

Informational. Not part of the ETA or LAMBDA rating.

Noise under high ambient temperature (indicative)Supplementary calculated results – outside the scope of accreditation

115V
LoadNormal ambient
fan · noise · intake
High ambient
fan · noise · intake
Noise change
10%707 RPM · 15.6 dB(A) · 30.6 °C731 RPM · 16.5 dB(A) · 34.4 °C+0.9 dB(A)
20%711 RPM · 15.6 dB(A) · 30.3 °C735 RPM · 17.1 dB(A) · 34.6 °C+1.5 dB(A)
50%1382 RPM · 36.4 dB(A) · 30.2 °C1722 RPM · 42.6 dB(A) · 36.2 °C+6.2 dB(A)
100%1853 RPM · 46.0 dB(A) · 31.0 °C1869 RPM · 46.3 dB(A) · 39.3 °C+0.3 dB(A)
Info

Fan speed, noise and the measured intake temperature at 10, 20, 50 and 100 % load, from the two load regulation tests: at normal ambient (about 30-32 °C) and at high ambient (about 40-47 °C). These are stabilized readings at fixed loads, not averages over the certification sweep, so they are indicative of how the fan behaves when it is hot. "<6.0" is the floor of our sound meter: the fan is stopped or too quiet to measure (the fan speed column says which); with the fan stopped, the intake sensor can read higher than the chamber air.

Informational. Not part of the ETA or LAMBDA rating.

Section D: ATX

Efficiency With 10W (≤500W) or 2% (>500W) Load51.944%
Hold Up Time13.70ms
Power OK11.00ms
Power OK to DC Loss2.70ms
Test\Rail+12V5V3.3V5VSB
100ms12.2044.9853.3295.181
10ms11.8434.9783.3275.172
1ms11.6924.9733.3165.171
0.1ms12.0444.9783.3155.177

Section E: Information about DUT

Product Identification Details
BrandABKO
ModelCOREMAX 500W BRONZE
OEM/ODMPREE
Serial Number-
Product Specifications
Manufacturer
Rated Voltage (Vrms)115-230
Rated Current (Arms)10
Rated Frequency (Hz)50-60
Rated Power (W)500
Operating Temperature (Continuous Full Load) (°C)0 - 40
TypeATX12V
Cable DesignFixed cables
WarrantyNo Info
Cybenetics
Dimensions (W x H x D)150 x 85 x 140mm
Weight1.63 kg (3.59 lb)
Cooling120mm Sleeve Bearing Fan (W12025HZ12SEMA)
Semi-Passive Operation✗
Cybenetics Testing Information
Lab IDAB50003398
Date of receiptJul 28, 2026
Testing DateAug 27, 2026
Report Issued DateSep 3, 2026
Engineer NameEfstathios Papadopoulos
Authorized By the Laboratory Technical ManagerAristeidis Bitziopoulos
Signature

Cables And Connectors(Non-accredited measurements)

Captive Cables
Description Cable Count Connector Count (Total) Gauge Cable Type
ATX connector 20+4 pin (520mm) 1 1 18AWG Tinned Copper
4+4 pin EPS12V (630mm+150mm) 1 2 18AWG Tinned Copper
6+2 pin PCIe (600mm) 1 1 18AWG Tinned Copper
6+2 pin PCIe (600mm+150mm) 1 2 18AWG Tinned Copper
SATA (450mm+150mm+150mm+150mm) 1 4 18AWG Tinned Copper
SATA (450mm+150mm) / 4-pin Molex (+150mm) 1 2/1 18AWG Tinned Copper
4-pin Molex (450mm+150mm) / SATA (+150mm) 1 2/1 18AWG Tinned Copper

Protection Features(Non-accredited measurements)

Over Power Protection✓
Over Current (+12V) Protection✓
Over Temperature Protection✓
Short Circuit Protection✓
Surge Protection✗
Inrush Current Protection✓
Fan Failure Protection✗

Parts Description

General Data
Manufacturer (OEM) PREE
PCB Type Double-Sided
Primary Side
Transient Filter 4x Y caps, 2x X caps, 2x CM chokes
Inrush Protection NTC Thermistor 2.5D-9 (2.5 Ohm @ 25°C)
Bridge Rectifier 1x Diodes GBU1510 (1000V, 8A @ 100°C)
APFC MOSFETs 2x Maple Semiconductor SLP18N50S (500V, 11.7A @ 100°C, Rds(on): 0.330Ohm)
APFC Boost Diode Microsemi UF860 (600V, 8A @ 25°C)
Bulk Cap(s) Toshin Kogyo (420V, 270uF, 2000h @ 105°C, LA)
Main Switchers 2x Maple Semiconductor SLP18N50S (500V, 11.7A @ 100°C, Rds(on): 0.330Ohm)

PFC/PWM Combo Controller

Champion CM6805BG

Topology Primary side: APFC, Double Forward
Secondary side: [12V] Passive Rectification & [Minor Rails] DC-DC converters
Secondary Side
+12V MOSFETs 5x HS 6NX014
5V & 3.3V DC-DC Converters: 4x AP70N03NF (30V, 51A @ 100°C, Rds(on): 5.5mOhm)
PWM Controller(s): ANPEC  APW7159C
Filtering Capacitors

Electrolytic:
12x 12Kuang Jin (2-3,000 @ 105°C, GR )
Polymer:
2x

Supervisor IC EST 7610FS
Fan Model WAM W12025HZ12SEMA (120mm, 12V, 0.20A, Rifle Bearing Fan)
5VSB Circuit
Rectifier HS 6NX014
Standby PWM Controller EST 2816H

Photos

Top side
Top side
Power specifications label
Power specifications label
Fan
Fan
PSU Internals
PSU Internals

Section F: Uncertainty

Efficiency Uncertainty Estimation

F.1 General Statement

Measurement uncertainty associated with the reported results was evaluated and estimated in accordance with JCGM 100:2008 (Guide to the Expression of Uncertainty in Measurement — GUM) and ISO/IEC 17025:2017, Clauses 7.6 and 7.2.

The uncertainty budget accounts for all significant identified contributors arising from the measurement process, instrumentation, test conditions, and operator interaction.

The reported expanded uncertainty U is obtained by multiplying the combined standard uncertainty uc by a coverage factor k = 2, corresponding to a confidence level of approximately 95 %, assuming a normal probability distribution.

Unless otherwise stated, the reported uncertainty applies only to the specific measurements performed and does not include long-term drift, aging effects, or future environmental changes.

F.2 Expanded Measurement Uncertainty by Measurement Type

Measurement Expanded Uncertainty U (k=2, norm)
Efficiency ±0.43%
Timings ±2.64ms
Power Excursions (Transient Response) ±0.18V
Conducted EMI Emissions (150 kHz – 30 MHz) ±2.35 dB
Noise Output ±1.23 dB