CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus
Sharkoon S25-V2
Lab IDSKCAS00179
  • Report ID: 3451
  • Report Date: Oct 5, 2026
  • Sample Received: Jun 20, 2026
  • Test Start: Sep 28, 2026
  • Test End: Sep 28, 2026
  • Noise Measurement Date: Sep 28, 2026
  • Entry Report Date: Oct 6, 2026
  • Analyst: Efstathios Papadopoulos
Scheme: DELTA
Noise Rating
DELTA is a Cybenetics rating. It is not part of our ISO/IEC 17065 certification schemes and is outside our accreditation.
Aristeidis Bitziopoulos, Certification Body General Manager

General Information

Test Equipment

Technical Specifications Table

Noise Measurements Test Set Up

Noise Damping Performance (DELTA)

Measured Chassis Graphs

Sharkoon S25-V2 > Stock Fans RPM - Each Fan

Sharkoon S25-V2 > Stock Fans RPM - Each Fan

Fan 1 · Fan 2

Sharkoon S25-V2 > Stock Fans RPM - Average of All Fans

Sharkoon S25-V2 > Stock Fans RPM - Average of All Fans

Sharkoon S25-V2 > Stock Fans Noise Output - LAeq

Sharkoon S25-V2 > Stock Fans Noise Output - LAeq

Sharkoon S25-V2 > Stock Fans Noise Output - LAeq per Fan Speed

Sharkoon S25-V2 > Stock Fans Noise Output - LAeq per Fan Speed

Sharkoon S25-V2 > Noise Damping Performance - 1/3 Octave Bands

Higher is Better

Sharkoon S25-V2 > Noise Damping Performance - 1/3 Octave Bands
Insertion loss: the open-air level minus the level with the speaker inside the chassis, per 1/3-octave band (LAeq). Positive values mean the chassis reduces the noise; negative values mean it amplifies it. (R) marks the resonance flag (-3 dB or lower); (≥) marks a lower bound.

Sharkoon S25-V2 > Noise Damping Performance - Octave Bands

Higher is Better

Sharkoon S25-V2 > Noise Damping Performance - Octave Bands
Insertion loss: the open-air level minus the level with the speaker inside the chassis, per octave band (LAeq). Positive values mean the chassis reduces the noise; negative values mean it amplifies it.

Sharkoon S25-V2 > Pink Noise - Open Air vs Inside the Chassis

Sharkoon S25-V2 > Pink Noise - Open Air vs Inside the Chassis
The pink noise source measured in open air and inside the chassis (LAeq per 1/3-octave band).

Open air · Inside the chassis

Sharkoon S25-V2

Case Photo
Case Photo #2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics runs voluntary certification programs for power supplies - ETA for efficiency, LAMBDA for noise and SAFE for safety and correct operation - and for cooling products, with DELTA for chassis soundproofing and PHI for fan airflow and static pressure. THETA rates cooler performance on AMD AM5 and Intel LGA1851 outside ISO 17065 and accreditation scope
CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus