This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227
72.063%
0.019
5.037V
0.315
115.14V
2
0.090A
0.453
76.780%
0.035
5.036V
0.590
115.14V
3
0.550A
2.767
80.883%
0.187
5.029V
3.421
115.15V
4
1.000A
5.025
82.634%
0.295
5.024V
6.081
115.14V
5
1.500A
7.527
82.988%
0.380
5.017V
9.070
115.14V
6
3.000A
14.993
82.019%
0.513
4.997V
18.280
115.13V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227
64.857%
0.007
5.037V
0.350
230.20V
2
0.090A
0.453
72.134%
0.011
5.036V
0.628
230.20V
3
0.550A
2.766
79.620%
0.062
5.030V
3.474
230.17V
4
1.000A
5.025
80.003%
0.109
5.024V
6.281
230.18V
5
1.500A
7.527
81.532%
0.156
5.018V
9.232
230.19V
6
3.000A
14.994
82.475%
0.270
4.998V
18.180
230.19V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
11.512A
2.009A
1.999A
1.006A
160.007
92.384%
0
<6.0
44.23°C
0.958
12.022V
4.979V
3.304V
4.971V
173.198
40.12°C
115.12V
2
24.056A
3.014A
2.998A
1.208A
320.053
94.268%
0
<6.0
45.03°C
0.989
12.020V
4.976V
3.303V
4.967V
339.515
40.51°C
115.13V
3
36.887A
3.518A
3.498A
1.411A
479.326
94.472%
0
<6.0
46.51°C
0.995
12.017V
4.974V
3.303V
4.963V
507.374
41.64°C
115.11V
4
49.820A
4.024A
3.996A
1.613A
639.740
94.137%
0
<6.0
47.58°C
0.997
12.014V
4.972V
3.302V
4.960V
679.584
42.35°C
115.10V
5
62.399A
5.028A
4.999A
1.816A
799.905
93.761%
562
9.7
42.43°C
0.998
12.010V
4.970V
3.301V
4.957V
853.130
48.15°C
115.11V
6
74.973A
6.041A
6.003A
2.000A
959.916
93.311%
651
13.5
42.65°C
0.999
12.007V
4.967V
3.299V
4.953V
1028.729
49.14°C
115.10V
7
87.525A
7.054A
7.005A
2.223A
1119.780
92.742%
741
17.0
43.56°C
0.998
12.004V
4.965V
3.298V
4.950V
1207.411
50.57°C
115.10V
8
100.151A
8.002A
8.011A
2.427A
1280.026
92.079%
876
22.9
44.11°C
0.998
12.001V
4.962V
3.296V
4.946V
1390.133
51.61°C
115.11V
9
113.115A
8.572A
8.496A
2.428A
1439.652
91.359%
1458
38.5
45.10°C
0.999
11.998V
4.958V
3.295V
4.944V
1575.812
53.29°C
115.11V
10
125.919A
9.084A
9.016A
3.041A
1600.112
90.579%
1800
44.4
45.80°C
0.999
11.995V
4.955V
3.294V
4.934V
1766.529
54.87°C
115.13V
11
139.297A
9.090A
9.019A
3.043A
1760.167
89.816%
1922
44.4
46.52°C
0.996
11.992V
4.952V
3.293V
4.931V
1959.737
56.40°C
115.14V
CL1
0.116A
22.001A
22.002A
0.000A
183.588
87.948%
857
22.3
41.96°C
0.972
12.023V
4.984V
3.297V
5.014V
208.746
48.85°C
115.15V
CL2
133.373A
1.000A
0.999A
1.000A
1613.019
90.766%
1751
43.8
45.87°C
0.999
11.995V
4.959V
3.298V
4.956V
1777.124
54.46°C
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
11.509A
2.007A
1.998A
1.006A
159.964
93.349%
0
<6.0
44.27°C
0.960
12.023V
4.979V
3.303V
4.970V
171.361
40.21°C
230.17V
2
24.051A
3.015A
2.998A
1.208A
319.998
95.165%
0
<6.0
45.15°C
0.985
12.020V
4.976V
3.303V
4.967V
336.257
40.46°C
230.19V
3
36.872A
3.519A
3.498A
1.411A
479.145
95.747%
0
<6.0
46.64°C
0.994
12.017V
4.973V
3.302V
4.963V
500.429
41.44°C
230.20V
4
49.807A
4.024A
3.999A
1.614A
639.589
95.462%
0
<6.0
47.50°C
0.993
12.014V
4.971V
3.301V
4.959V
669.991
41.53°C
230.20V
5
62.381A
5.032A
5.000A
1.817A
799.772
95.322%
571
9.8
42.05°C
0.997
12.011V
4.969V
3.301V
4.956V
839.021
48.57°C
230.21V
6
74.962A
6.042A
6.001A
2.000A
959.776
95.202%
649
13.5
42.54°C
0.998
12.007V
4.966V
3.299V
4.953V
1008.149
49.50°C
230.22V
7
87.516A
7.057A
7.005A
2.223A
1119.677
94.969%
752
17.7
43.47°C
0.997
12.004V
4.964V
3.298V
4.949V
1178.989
50.88°C
230.23V
8
100.146A
8.001A
8.012A
2.427A
1279.946
94.648%
869
22.8
43.89°C
0.998
12.001V
4.961V
3.295V
4.945V
1352.318
51.87°C
230.24V
9
113.108A
8.575A
8.497A
2.428A
1439.576
94.260%
1325
35.7
44.67°C
0.998
11.998V
4.957V
3.295V
4.943V
1527.239
53.51°C
230.24V
10
125.922A
9.085A
9.017A
3.042A
1600.024
93.808%
1769
44.0
45.13°C
0.999
11.994V
4.954V
3.294V
4.933V
1705.635
54.54°C
230.25V
11
139.293A
9.091A
9.019A
3.043A
1760.112
93.477%
1926
44.4
46.78°C
0.999
11.992V
4.951V
3.293V
4.930V
1882.942
56.70°C
230.27V
CL1
0.118A
22.001A
21.997A
0.000A
183.552
88.815%
849
21.9
42.88°C
0.967
12.023V
4.982V
3.297V
5.013V
206.668
49.05°C
230.29V
CL2
133.357A
1.000A
1.000A
1.000A
1612.923
93.997%
1638
41.4
45.02°C
0.999
11.995V
4.957V
3.297V
4.953V
1715.938
54.08°C
230.27V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.234A
0.500A
0.499A
0.200A
19.987
68.599%
0
<6.0
0.879
12.024V
5.000V
3.304V
5.000V
29.136
115.15V
2
2.468A
1.001A
0.998A
0.400A
39.977
81.806%
0
<6.0
0.942
12.024V
5.000V
3.304V
4.998V
48.868
115.15V
3
3.706A
1.499A
1.498A
0.601A
60.008
85.517%
0
<6.0
0.919
12.024V
5.000V
3.304V
4.996V
70.171
115.14V
4
4.936A
2.008A
2.000A
0.804A
79.957
88.172%
0
<6.0
0.918
12.024V
4.980V
3.304V
4.974V
90.683
115.13V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.234A
0.502A
0.498A
0.200A
19.987
67.944%
0
<6.0
0.562
12.027V
4.985V
3.305V
4.985V
29.417
230.32V
2
2.468A
1.002A
0.998A
0.402A
39.978
79.598%
0
<6.0
0.754
12.027V
4.984V
3.305V
4.982V
50.225
230.33V
3
3.705A
1.504A
1.497A
0.603A
60.007
83.144%
0
<6.0
0.851
12.027V
4.984V
3.305V
4.980V
72.172
230.33V
4
4.936A
2.005A
1.997A
0.804A
79.956
89.146%
0
<6.0
0.894
12.026V
4.984V
3.305V
4.978V
89.691
230.32V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.60mV
4.60mV
12.70mV
5.80mV
Pass
20% Load
5.80mV
4.40mV
12.80mV
5.50mV
Pass
30% Load
5.80mV
4.40mV
12.20mV
5.60mV
Pass
40% Load
7.00mV
4.60mV
12.90mV
5.90mV
Pass
50% Load
7.20mV
4.80mV
12.90mV
6.10mV
Pass
60% Load
6.40mV
4.90mV
12.20mV
5.60mV
Pass
70% Load
7.30mV
5.60mV
12.50mV
6.90mV
Pass
80% Load
7.70mV
5.50mV
14.30mV
6.40mV
Pass
90% Load
7.70mV
5.70mV
14.60mV
6.60mV
Pass
100% Load
10.30mV
6.20mV
15.00mV
6.60mV
Pass
110% Load
11.80mV
6.10mV
14.50mV
6.30mV
Pass
Crossload1
7.40mV
6.50mV
16.00mV
6.00mV
Pass
Crossload2
10.40mV
5.50mV
13.80mV
6.60mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.80mV
4.60mV
13.10mV
6.20mV
Pass
20% Load
6.00mV
4.70mV
13.20mV
6.20mV
Pass
30% Load
6.70mV
4.60mV
13.20mV
5.90mV
Pass
40% Load
7.00mV
4.70mV
13.60mV
6.10mV
Pass
50% Load
7.50mV
5.00mV
13.40mV
6.60mV
Pass
60% Load
6.90mV
5.50mV
13.50mV
6.90mV
Pass
70% Load
7.70mV
5.30mV
14.00mV
6.90mV
Pass
80% Load
8.20mV
5.50mV
14.10mV
6.80mV
Pass
90% Load
7.70mV
6.20mV
14.00mV
6.90mV
Pass
100% Load
10.80mV
6.30mV
15.60mV
6.70mV
Pass
110% Load
11.50mV
6.00mV
15.40mV
6.70mV
Pass
Crossload1
7.40mV
6.30mV
15.70mV
6.10mV
Pass
Crossload2
11.20mV
5.30mV
14.60mV
6.80mV
Pass
The results above are not used in the certification process
Corsair AX1600i
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case