Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
ATX connector 20+4 pin (620mm)
1
1
16-22AWG
4+4 pin EPS12V (660mm)
1
1
18AWG
Modular Cables
6+2 pin PCIe (600mm+150mm)
2
4
16-18AWG
SATA (450mm+115mm+115mm+115mm)
2
8
18AWG
4 pin Molex (450mm+100mm+100mm)+FDD (+100mm)
2
6 / 2
18-22AWG
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
25
25
70,8
3
0.8
Watts
130
850
15
9.6
Total Max. Power (W)
850
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
85.710%
Average Noise Output (>1450 Load Combinations)
39.16dBA
Average PF (>1450 Load Combinations)
0.990
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0513W
Non-Accredited
12V Ripple (Full Load)
30.88mV
5V Ripple (Full Load)
25.80mV
3.3V Ripple (Full Load)
20.64mV
5VSB Ripple (Full Load)
15.64mV
12V Load Regulation
1.71%
5V Load Regulation
2.39%
3.3V Load Regulation
2.52%
5VSB Load Regulation
4.22%
Inrush Current
49.264A
Accredited
Average Efficiency (>1450 load combinations)
88.415%
Average Noise Output (>1450 Load Combinations)
38.77dBA
Average PF (>1450 Load Combinations)
0.959
Efficiency With 10W (≤500W) or 2% (>500W) Load
-
Standby Power Consumption
0.0695W
Non-Accredited
12V Ripple (Full Load)
29.93mV
5V Ripple (Full Load)
35.66mV
3.3V Ripple (Full Load)
24.46mV
5VSB Ripple (Full Load)
15.26mV
12V Load Regulation
1.87%
5V Load Regulation
2.41%
3.3V Load Regulation
2.79%
5VSB Load Regulation
4.40%
Inrush Current
57.706A
Hold-Up Time & PWR_OK Signal
9.00ms
AC Loss to PWR_OK Hold Up Time
6.30ms
PWR_OK Inactive to DC Loss Delay
2.70ms
OPP (0.00°C / 0.00°C)
-
-
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
9
AC Loss to PWR_OK Hold Up Time (ms)
6.3
PWR_OK Inactive to DC Loss Delay (ms)
2.7
Stromverbrauch im Ruhezustand
Tables
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
68.590%
0.031
5.087V
0.312
115.13V
2
0.088A
0.446
75.338%
0.058
5.086V
0.592
115.13V
3
0.542A
2.753
80.923%
0.246
5.075V
3.402
115.12V
4
1.002A
5.076
80.931%
0.329
5.064V
6.272
115.12V
5
1.502A
7.586
80.497%
0.373
5.051V
9.424
115.12V
6
3.002A
15.048
78.951%
0.433
5.013V
19.060
115.12V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
62.757%
0.010
5.086V
0.341
230.34V
2
0.088A
0.446
70.794%
0.019
5.086V
0.630
230.34V
3
0.543A
2.753
78.590%
0.099
5.074V
3.503
230.33V
4
1.002A
5.075
79.695%
0.164
5.063V
6.368
230.33V
5
1.502A
7.584
79.773%
0.218
5.050V
9.507
230.33V
6
3.001A
15.039
78.586%
0.310
5.011V
19.137
230.33V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.188A
1.985A
2.003A
0.991A
84.809
82.421%
995
27.1
38.25°C
0.963
12.184V
5.042V
3.290V
5.046V
102.897
44.03°C
115.15V
2
11.413A
2.981A
3.015A
1.191A
169.705
87.187%
1168
30.6
38.77°C
0.980
12.164V
5.030V
3.282V
5.028V
194.644
44.79°C
115.15V
3
18.017A
3.488A
3.537A
1.396A
254.883
88.424%
1353
34.2
39.26°C
0.989
12.144V
5.020V
3.275V
5.008V
288.252
45.86°C
115.14V
4
24.624A
3.996A
4.036A
1.601A
339.762
88.508%
1520
38.2
39.84°C
0.992
12.125V
5.010V
3.268V
4.989V
383.879
47.20°C
115.15V
5
30.917A
5.000A
5.063A
1.810A
424.660
87.954%
1749
42.2
40.45°C
0.994
12.103V
4.996V
3.258V
4.970V
482.822
48.98°C
115.14V
6
37.244A
6.025A
6.089A
2.018A
509.657
87.030%
1939
45.4
41.38°C
0.996
12.079V
4.982V
3.249V
4.949V
585.612
51.01°C
115.14V
7
43.591A
7.041A
7.128A
2.230A
594.606
85.987%
2030
45.8
42.83°C
0.996
12.056V
4.968V
3.240V
4.932V
691.506
54.40°C
115.17V
8
49.941A
8.080A
8.172A
2.442A
679.590
84.912%
2030
45.8
44.39°C
0.997
12.038V
4.953V
3.230V
4.908V
800.347
58.10°C
115.14V
9
56.789A
8.600A
8.721A
2.450A
764.621
83.857%
2030
45.8
44.87°C
0.997
12.010V
4.943V
3.221V
4.892V
911.817
60.42°C
115.14V
10
63.377A
9.128A
9.243A
3.081A
849.397
82.561%
2030
45.8
45.88°C
0.998
11.987V
4.932V
3.213V
4.862V
1028.812
62.97°C
115.15V
11
70.609A
9.139A
9.258A
3.091A
934.386
81.169%
2030
45.8
46.86°C
0.998
11.963V
4.926V
3.207V
4.847V
1151.168
66.32°C
115.14V
CL1
0.100A
16.028A
16.002A
0.004A
132.005
79.629%
1775
42.5
45.10°C
0.975
12.159V
4.928V
3.236V
5.044V
165.775
54.26°C
115.16V
CL2
70.786A
1.004A
1.002A
1.002A
861.427
82.802%
2030
45.8
47.11°C
0.998
11.983V
4.994V
3.244V
4.925V
1040.340
64.39°C
115.14V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.197A
1.984A
2.004A
0.991A
84.826
84.238%
995
27.1
40.20°C
0.870
12.167V
5.042V
3.290V
5.044V
100.698
42.53°C
230.27V
2
11.431A
2.980A
3.015A
1.191A
169.688
88.925%
1180
30.7
40.85°C
0.931
12.145V
5.029V
3.279V
5.026V
190.822
43.42°C
230.27V
3
18.051A
3.488A
3.544A
1.396A
254.895
90.201%
1353
34.2
41.05°C
0.952
12.122V
5.019V
3.270V
5.004V
282.584
43.84°C
230.27V
4
24.677A
3.995A
4.043A
1.603A
339.785
90.445%
1550
38.5
41.88°C
0.965
12.100V
5.009V
3.263V
4.984V
375.681
45.20°C
230.26V
5
30.988A
5.003A
5.071A
1.810A
424.669
90.150%
1775
42.5
42.19°C
0.971
12.076V
4.994V
3.251V
4.965V
471.067
45.88°C
230.29V
6
37.323A
6.027A
6.106A
2.020A
509.691
89.697%
1920
45.0
42.81°C
0.976
12.054V
4.980V
3.242V
4.945V
568.239
47.03°C
230.28V
7
43.689A
7.044A
7.147A
2.231A
594.593
89.019%
2030
45.8
43.21°C
0.980
12.029V
4.966V
3.231V
4.924V
667.936
47.79°C
230.31V
8
50.087A
8.079A
8.196A
2.446A
679.594
88.276%
2030
45.8
43.95°C
0.983
12.003V
4.953V
3.221V
4.900V
769.852
48.93°C
230.29V
9
56.946A
8.602A
8.750A
2.455A
764.640
87.468%
2030
45.8
44.81°C
0.986
11.977V
4.942V
3.211V
4.884V
874.195
50.50°C
230.28V
10
63.577A
9.131A
9.273A
3.091A
849.445
86.353%
2030
45.8
45.26°C
0.987
11.950V
4.930V
3.202V
4.850V
983.689
51.22°C
230.53V
11
70.856A
9.147A
9.295A
3.101A
934.382
85.274%
2030
45.8
46.25°C
0.989
11.921V
4.922V
3.195V
4.833V
1095.736
52.66°C
230.35V
CL1
0.100A
16.029A
16.004A
0.005A
132.308
80.983%
1460
36.9
41.63°C
0.924
12.150V
4.942V
3.240V
5.046V
163.377
45.83°C
230.43V
CL2
70.791A
1.004A
1.002A
1.002A
859.262
86.934%
2030
45.8
45.74°C
0.987
11.952V
4.986V
3.231V
4.914V
988.404
51.82°C
230.29V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.195A
0.493A
0.479A
0.196A
19.653
62.713%
960
26.2
0.915
12.202V
5.062V
3.302V
5.076V
31.338
115.15V
2
2.418A
0.981A
1.000A
0.391A
39.724
74.644%
960
26.2
0.968
12.196V
5.053V
3.296V
5.068V
53.218
115.15V
3
3.645A
1.478A
1.514A
0.591A
59.876
79.508%
960
26.2
0.966
12.191V
5.049V
3.294V
5.060V
75.308
115.15V
4
4.861A
1.986A
2.002A
0.791A
79.832
82.209%
960
26.2
0.963
12.185V
5.043V
3.291V
5.052V
97.108
115.15V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.201A
0.490A
0.482A
0.196A
19.702
65.047%
960
26.2
0.621
12.186V
5.061V
3.302V
5.076V
30.289
230.27V
2
2.423A
0.980A
0.998A
0.391A
39.731
76.132%
960
26.2
0.772
12.179V
5.053V
3.295V
5.068V
52.187
230.26V
3
3.651A
1.476A
1.514A
0.591A
59.874
81.409%
960
26.2
0.829
12.174V
5.048V
3.293V
5.059V
73.547
230.26V
4
4.865A
1.985A
2.005A
0.791A
79.803
84.312%
960
26.2
0.861
12.169V
5.043V
3.290V
5.050V
94.652
230.26V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.1 mV
22.2 mV
14.5 mV
9.4 mV
Pass
20% Load
14.5 mV
27.1 mV
14.9 mV
10.1 mV
Pass
30% Load
13.8 mV
27.8 mV
15.6 mV
10.1 mV
Pass
40% Load
14.7 mV
28.5 mV
16.3 mV
12.0 mV
Pass
50% Load
17.8 mV
22.8 mV
18.1 mV
10.9 mV
Pass
60% Load
21.1 mV
23.0 mV
16.3 mV
11.9 mV
Pass
70% Load
20.5 mV
24.2 mV
17.8 mV
13.8 mV
Pass
80% Load
21.4 mV
25.0 mV
18.7 mV
13.3 mV
Pass
90% Load
25.7 mV
22.5 mV
17.8 mV
13.3 mV
Pass
100% Load
30.9 mV
25.8 mV
20.6 mV
15.6 mV
Pass
110% Load
35.3 mV
28.0 mV
20.9 mV
15.6 mV
Pass
Crossload 1
22.2 mV
27.3 mV
17.9 mV
13.0 mV
Pass
Crossload 2
28.9 mV
26.3 mV
16.8 mV
14.1 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.6 mV
17.5 mV
12.6 mV
7.4 mV
Pass
20% Load
12.5 mV
17.9 mV
13.6 mV
7.8 mV
Pass
30% Load
10.1 mV
20.6 mV
14.2 mV
8.2 mV
Pass
40% Load
14.4 mV
23.1 mV
14.7 mV
12.6 mV
Pass
50% Load
19.4 mV
21.8 mV
14.4 mV
8.9 mV
Pass
60% Load
20.4 mV
24.4 mV
16.1 mV
10.0 mV
Pass
70% Load
20.3 mV
26.8 mV
17.3 mV
11.1 mV
Pass
80% Load
20.6 mV
29.3 mV
18.8 mV
12.3 mV
Pass
90% Load
25.1 mV
31.7 mV
21.1 mV
14.2 mV
Pass
100% Load
29.9 mV
35.7 mV
24.5 mV
15.3 mV
Pass
110% Load
34.8 mV
37.4 mV
24.6 mV
17.7 mV
Pass
Crossload 1
23.0 mV
28.8 mV
20.8 mV
13.1 mV
Pass
Crossload 2
27.5 mV
32.0 mV
19.7 mV
14.6 mV
Pass
The results above are not used in the certification process
Corsair CX850M
Top side
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern