| 115V | 230V | |
| Scheme: ETA-EMI PSU | ![]() |
![]() |
| 115V | 230V | |
![]() |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load range | Points | Efficiency 115V | Efficiency 230V | PF 115V | PF 230V |
|---|---|---|---|---|---|
| 0-<20 % | 200 / 200 | 84.31% | 84.97% | 0.976 | 0.874 |
| 20-<40 % | 318 / 318 | 89.34% | 90.84% | 0.993 | 0.965 |
| 40-<60 % | 319 / 319 | 90.45% | 92.41% | 0.994 | 0.981 |
| 60-<80 % | 318 / 318 | 89.84% | 92.34% | 0.994 | 0.987 |
| 80-100 % | 326 / 326 | 88.59% | 91.82% | 0.996 | 0.990 |
| 70-100 % (High-Load) | 486 / 486 | 88.92% | 91.96% | 0.995 | 0.989 |
| All (published average) | 1481 / 1481 | 88.84% | 90.92% | 0.992 | 0.966 |
Informational. Not part of the ETA or LAMBDA rating.
| Load range | Noise 115V avg (loudest) | Noise 230V avg (loudest) | Fan off 115V / 230V |
|---|---|---|---|
| 0-<20 % | <6.0 (<6.0) | <6.0 (<6.0) | 9% / 8% |
| 20-<40 % | <6.0 (<6.0) | <6.0 (<6.0) | 0% / 0% |
| 40-<60 % | <6.0 (<6.0) | <6.0 (<6.0) | 0% / 0% |
| 60-<80 % | 6.1 (18.4) | <6.0 (<6.0) | 0% / 0% |
| 80-100 % | 20.9 (25.9) | 20.7 (25.9) | 0% / 0% |
| 70-100 % (High-Load) | 19.2 (25.9) | 19.0 (25.9) | 0% / 0% |
| All (published average) | 14.7 (25.9) | 14.5 (25.9) | 1% / 1% |
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 44.3 °C | 0 RPM · <6.0 dB(A) · 44.3 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 45.1 °C | 0 RPM · <6.0 dB(A) · 45.1 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 48.9 °C | 0 RPM · <6.0 dB(A) · 48.9 °C | fan off in both |
| 100% | 1279 RPM · 34.0 dB(A) · 45.4 °C | 1279 RPM · 34.0 dB(A) · 45.4 °C | +0.0 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 44.6 °C | 0 RPM · <6.0 dB(A) · 44.6 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 45.4 °C | 0 RPM · <6.0 dB(A) · 45.4 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 48.6 °C | 0 RPM · <6.0 dB(A) · 48.6 °C | fan off in both |
| 100% | 1222 RPM · 33.2 dB(A) · 46.0 °C | 1222 RPM · 33.2 dB(A) · 46.0 °C | +0.0 dB(A) |