This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
63.597%
0.035
5.166V
0.365W
115.17V
2
0.09A
0.465W
69.948%
0.064
5.163V
0.665W
115.17V
3
0.55A
2.829W
80.065%
0.263
5.145V
3.533W
115.16V
4
1A
5.128W
80.323%
0.352
5.128V
6.384W
115.17V
5
1.5A
7.666W
80.013%
0.408
5.111V
9.58W
115.16V
6
2.499A
12.681W
79.346%
0.462
5.074V
15.982W
115.16V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
50.516%
0.013
5.165V
0.459W
230.33V
2
0.09A
0.464W
61.366%
0.022
5.162V
0.757W
230.33V
3
0.55A
2.829W
76.875%
0.102
5.145V
3.679W
230.33V
4
1A
5.128W
78.365%
0.168
5.128V
6.543W
230.33V
5
1.5A
7.665W
78.714%
0.224
5.11V
9.738W
230.33V
6
2.499A
12.68W
79.248%
0.301
5.074V
16.001W
230.33V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.387A
1.977A
1.967A
0.974A
99.985
86.87%
0
<6.0
45.28°C
0.981
12.273V
5.058V
3.355V
5.133V
115.1
40.96°C
115.16V
20%
13.786A
2.968A
2.954A
1.172A
199.927
90.053%
0
<6.0
46.2°C
0.996
12.262V
5.054V
3.351V
5.119V
222.007
41.46°C
115.12V
30%
21.541A
3.465A
3.45A
1.371A
299.968
90.867%
0
<6.0
47.36°C
0.995
12.252V
5.051V
3.348V
5.106V
330.115
42.01°C
115.1V
40%
29.264A
3.963A
3.946A
1.571A
399.469
90.913%
0
<6.0
48.52°C
0.995
12.243V
5.047V
3.345V
5.093V
439.392
42.77°C
115.06V
50%
36.677A
4.957A
4.938A
1.772A
499.168
90.573%
1033
24.6
43.18°C
0.995
12.233V
5.043V
3.341V
5.079V
551.124
49.19°C
115.04V
60%
44.181A
5.958A
5.935A
1.976A
599.697
90.113%
1035
24.6
43.49°C
0.995
12.220V
5.036V
3.336V
5.062V
665.492
50.23°C
115V
70%
51.626A
6.957A
6.933A
2.179A
699.419
89.454%
1076
25.7
43.78°C
0.994
12.209V
5.031V
3.332V
5.047V
781.873
51.25°C
114.97V
80%
59.156A
7.959A
7.929A
2.283A
799.425
88.671%
1509
35.8
44.23°C
0.993
12.197V
5.027V
3.328V
5.036V
901.563
52.25°C
114.93V
90%
67.026A
8.46A
8.419A
2.387A
899.187
87.796%
1882
43.3
45.2°C
0.992
12.185V
5.023V
3.324V
5.026V
1024.191
54.29°C
114.89V
100%
74.977A
8.965A
8.94A
2.492A
999.906
86.809%
2276
47.5
45.83°C
0.991
12.174V
5.018V
3.321V
5.016V
1151.846
55.85°C
114.85V
110%
82.555A
9.971A
10.037A
2.495A
1099.721
85.486%
2687
51.0
46.5°C
0.99
12.161V
5.014V
3.316V
5.009V
1286.444
57.42°C
114.81V
CL1
0.114A
14.318A
14.278A
0A
121.272
82.989%
0
<6.0
48.26°C
0.988
12.264V
5.042V
3.34V
5.156V
146.129
42.74°C
115.14V
CL2
0.112A
19.811A
0A
0A
101.383
81.743%
939
21.6
43.89°C
0.982
12.270V
5.048V
3.349V
5.164V
124.028
50.99°C
115.15V
CL3
0.112A
0A
19.707A
0A
67.364
77.267%
0
<6.0
52.64°C
0.971
12.260V
5.061V
3.348V
5.16V
87.185
44.56°C
115.16V
CL4
82.057A
0A
0A
0A
999.805
87.427%
2019
44.4
45.29°C
0.991
12.184V
5.031V
3.331V
5.118V
1143.59
55.21°C
114.86V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.386A
1.977A
1.967A
0.974A
99.967
88.208%
0
<6.0
44.35°C
0.892
12.272V
5.058V
3.355V
5.134V
113.33
40.11°C
230.36V
20%
13.784A
2.968A
2.954A
1.172A
199.898
91.573%
0
<6.0
45.29°C
0.951
12.261V
5.054V
3.351V
5.12V
218.295
40.62°C
230.35V
30%
21.536A
3.464A
3.449A
1.371A
299.935
92.393%
0
<6.0
46.62°C
0.97
12.254V
5.052V
3.348V
5.106V
324.628
41.48°C
230.33V
40%
29.254A
3.961A
3.945A
1.571A
399.364
92.551%
0
<6.0
47.26°C
0.979
12.244V
5.048V
3.345V
5.093V
431.506
41.62°C
230.32V
50%
36.690A
4.961A
4.941A
1.774A
499.265
92.478%
0
<6.0
48.82°C
0.983
12.231V
5.041V
3.339V
5.074V
539.872
42.88°C
230.3V
60%
44.191A
5.959A
5.937A
1.976A
599.759
92.233%
1032
24.5
42.95°C
0.984
12.218V
5.035V
3.335V
5.061V
650.262
49.36°C
230.29V
70%
51.632A
6.957A
6.934A
2.179A
699.424
91.9%
1152
27.8
43.47°C
0.983
12.208V
5.032V
3.332V
5.047V
761.078
50.54°C
230.27V
80%
59.154A
7.957A
7.929A
2.282A
799.404
91.406%
1682
39.4
44.33°C
0.982
12.197V
5.028V
3.328V
5.036V
874.56
52.39°C
230.26V
90%
67.020A
8.458A
8.418A
2.386A
899.15
90.876%
1999
43.9
44.65°C
0.98
12.186V
5.024V
3.324V
5.026V
989.423
53.66°C
230.25V
100%
74.971A
8.963A
8.939A
2.491A
999.857
90.323%
2366
48.1
45.12°C
0.977
12.174V
5.019V
3.321V
5.016V
1106.97
55.2°C
230.24V
110%
82.540A
9.968A
10.036A
2.494A
1099.678
89.551%
2788
51.6
46.61°C
0.974
12.162V
5.015V
3.317V
5.01V
1227.993
57.52°C
230.22V
CL1
0.112A
14.312A
14.274A
0A
121.266
84.495%
1027
24.4
42.33°C
0.92
12.264V
5.044V
3.341V
5.157V
143.516
48.81°C
230.35V
CL2
0.112A
19.808A
0A
0A
101.378
83.2%
0
<6.0
50.75°C
0.902
12.271V
5.049V
3.349V
5.164V
121.848
43.66°C
230.36V
CL3
0.112A
0A
19.71A
0A
67.36
78.626%
0
<6.0
52.69°C
0.846
12.260V
5.06V
3.348V
5.16V
85.675
44.62°C
230.36V
CL4
82.060A
0A
0A
0A
999.864
90.911%
2088
46.1
45.63°C
0.977
12.184V
5.03V
3.331V
5.117V
1099.822
55.54°C
230.24V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.206A
0.494A
0.491A
0.194A
19.99
66.898%
0
<6.0
40.19°C
0.884
12.312V
5.062V
3.359V
5.166V
29.883
37.07°C
115.18V
40W
2.662A
0.691A
0.688A
0.29A
39.989
77.998%
0
<6.0
40.82°C
0.942
12.279V
5.061V
3.358V
5.162V
51.269
37.46°C
115.17V
60W
4.118A
0.889A
0.884A
0.388A
59.987
82.921%
0
<6.0
41.82°C
0.962
12.268V
5.061V
3.357V
5.157V
72.342
38.06°C
115.17V
80W
5.569A
1.087A
1.081A
0.485A
79.935
85.718%
0
<6.0
44.08°C
0.973
12.266V
5.06V
3.356V
5.153V
93.254
40.1°C
115.16V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.205A
0.494A
0.491A
0.194A
19.984
67.829%
0
<6.0
39.72°C
0.523
12.310V
5.061V
3.358V
5.165V
29.46
36.61°C
230.37V
40W
2.662A
0.692A
0.688A
0.29A
39.985
79.215%
0
<6.0
41.78°C
0.707
12.278V
5.06V
3.357V
5.161V
50.474
38.5°C
230.37V
60W
4.118A
0.889A
0.884A
0.388A
59.984
84.209%
0
<6.0
42.51°C
0.804
12.266V
5.06V
3.357V
5.157V
71.204
39.01°C
230.35V
80W
5.568A
1.087A
1.081A
0.485A
79.918
87.023%
0
<6.0
43.1°C
0.858
12.264V
5.06V
3.356V
5.153V
91.834
39.24°C
230.36V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
16.93mV
8.39mV
7.79mV
9.61mV
Pass
20% Load
27.95mV
13.57mV
15.77mV
43.06mV
Pass
30% Load
24.35mV
12.81mV
13.09mV
36.33mV
Pass
40% Load
14.11mV
8.28mV
8.14mV
9.26mV
Pass
50% Load
29.41mV
12.85mV
17.44mV
38.96mV
Pass
60% Load
14.91mV
9.00mV
10.57mV
10.98mV
Pass
70% Load
32.23mV
14.99mV
19.01mV
38.15mV
Pass
80% Load
15.93mV
10.82mV
14.00mV
11.69mV
Pass
90% Load
27.14mV
15.96mV
19.92mV
36.33mV
Pass
100% Load
23.02mV
11.90mV
16.22mV
14.22mV
Pass
110% Load
23.81mV
11.90mV
17.12mV
14.49mV
Pass
Crossload1
18.81mV
14.80mV
14.84mV
10.45mV
Pass
Crossload2
16.48mV
12.09mV
10.57mV
9.82mV
Pass
Crossload3
24.35mV
12.15mV
15.62mV
36.99mV
Pass
Crossload4
23.08mV
11.18mV
15.07mV
13.88mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
42.91mV
15.86mV
16.13mV
42.86mV
Pass
20% Load
35.32mV
15.45mV
14.71mV
41.80mV
Pass
30% Load
12.07mV
6.81mV
8.24mV
9.87mV
Pass
40% Load
36.18mV
16.46mV
18.20mV
43.21mV
Pass
50% Load
29.97mV
13.32mV
15.78mV
38.71mV
Pass
60% Load
35.24mV
16.11mV
17.95mV
41.54mV
Pass
70% Load
33.67mV
16.67mV
15.57mV
43.42mV
Pass
80% Load
16.23mV
10.82mV
14.51mV
11.54mV
Pass
90% Load
29.06mV
13.87mV
19.41mV
37.34mV
Pass
100% Load
23.60mV
15.36mV
16.52mV
13.81mV
Pass
110% Load
24.70mV
12.19mV
17.50mV
15.22mV
Pass
Crossload1
18.26mV
16.19mV
13.85mV
10.34mV
Pass
Crossload2
35.32mV
16.21mV
16.68mV
37.39mV
Pass
Crossload3
27.34mV
11.74mV
14.11mV
36.43mV
Pass
Crossload4
23.33mV
12.58mV
15.07mV
13.04mV
Pass
The results above are not used in the certification process
FSP Technology Hydro G Pro 1000W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted