Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (620mm)
1
1
16-18AWG
No
4+4 pin EPS12V (710mm)
2
2
16AWG
No
6+2 pin PCIe (760mm)
3
3
16AWG
No
12+4 pin PCIe (760mm) (600W)
1
1
16-28AWG
No
SATA 3.3 (410mm+150mm)
1
2
18AWG
No
SATA (510mm+150mm+150mm+150mm)
4
16
18AWG
No
4 pin Molex (460mm+130mm+130mm)
1
3
18AWG
No
AC Power Cord (1380mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.0 Compliance
✓
Performance Summary
Efficiency Rating
PLATINUM
Noise Rating
A
Average Efficiency (>1450 load combinations)
89.388%
Average Noise Output (>1450 Load Combinations)
23.92dBA
Average PF (>1450 Load Combinations)
0.983
Efficiency With 10W (≤500W) or 2% (>500W) Load
74.411%
Standby Power Consumption
0.0703W
12V Ripple (Full Load)
19.39mV
5V Ripple (Full Load)
12.24mV
3.3V Ripple (Full Load)
19.17mV
5VSB Ripple (Full Load)
25.99mV
12V Load Regulation
0.63%
5V Load Regulation
0.50%
3.3V Load Regulation
1.06%
5VSB Load Regulation
2.42%
Inrush Current
35.310A
Efficiency Rating
PLATINUM
Noise Rating
A
Average Efficiency (>1450 load combinations)
91.420%
Average Noise Output (>1450 Load Combinations)
23.87dBA
Average PF (>1450 Load Combinations)
0.952
Efficiency With 10W (≤500W) or 2% (>500W) Load
74.282%
Standby Power Consumption
0.1527W
12V Ripple (Full Load)
19.99mV
5V Ripple (Full Load)
12.94mV
3.3V Ripple (Full Load)
19.59mV
5VSB Ripple (Full Load)
25.75mV
12V Load Regulation
0.63%
5V Load Regulation
0.50%
3.3V Load Regulation
1.09%
5VSB Load Regulation
2.44%
Inrush Current
64.480A
12V Transient Response (200%)
11.42V
5V Transient Response (200%)
4.949V
3.3V Transient Response (200%)
3.206V
5VSB Transient Response (200%)
4.939V
Hold-Up Time & Power Ok Signal
21.20ms
AC Loss to PWR_OK Hold Up Time
16.70ms
PWR_OK Inactive to DC Loss Delay
4.50ms
PSU Timings: T1 (20% / 100%)
72.0ms
70.0ms
PSU Timings: T3 (20% / 100%)
130.0ms
128.0ms
OPP (29.18°C / 39.56°C)
138.62%
136.51%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
21.2
AC Loss to PWR_OK Hold Up Time (ms)
16.7
PWR_OK Inactive to DC Loss Delay (ms)
4.5
Vampire Power
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.93 V
114.89 V
113.85 V
114.96 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.98 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.417
1.490
PASS
Mains Voltage THD:
0.14 %
0.12 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.070 W
0.062 W
N/A
0.081 W
N/A
N/A
Apparent Power:
10.477 W
10.457 W
N/A
10.499 W
N/A
N/A
Power Factor:
0.007
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.88 V
229.85 V
227.70 V
229.94 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.417
1.490
PASS
Mains Voltage THD:
0.14 %
0.12 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.153 W
0.129 W
N/A
0.188 W
N/A
N/A
Apparent Power:
36.060 W
36.029 W
N/A
36.101 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
64.893%
0.034
5.162V
0.358W
114.93V
2
0.09A
0.464W
71.961%
0.06
5.161V
0.645W
114.93V
3
0.55A
2.833W
80.698%
0.263
5.151V
3.511W
114.93V
4
1A
5.141W
81.386%
0.366
5.141V
6.317W
114.94V
5
1.5A
7.695W
80.861%
0.42
5.13V
9.516W
114.94V
6
3A
15.289W
78.955%
0.499
5.096V
19.364W
114.94V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
51.028%
0.013
5.161V
0.456W
229.9V
2
0.09A
0.464W
61.724%
0.021
5.161V
0.752W
229.9V
3
0.55A
2.833W
78.061%
0.097
5.151V
3.629W
229.9V
4
1A
5.141W
79.82%
0.161
5.141V
6.439W
229.9V
5
1.5A
7.695W
80.131%
0.211
5.13V
9.605W
229.9V
6
3A
15.292W
80.744%
0.325
5.097V
18.938W
229.9V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.436A
1.971A
1.978A
0.974A
99.981
86.33%
0
<6.0
44.55°C
0.964
12.180V
5.071V
3.336V
5.131V
115.812
40.25°C
114.9V
20%
13.905A
2.959A
2.971A
1.172A
199.926
90.924%
0
<6.0
45.46°C
0.979
12.157V
5.069V
3.332V
5.121V
219.875
40.85°C
114.89V
30%
21.715A
3.453A
3.469A
1.37A
299.978
91.813%
0
<6.0
46.13°C
0.985
12.154V
5.067V
3.329V
5.11V
326.73
41.02°C
114.87V
40%
29.492A
3.949A
3.969A
1.569A
399.559
91.623%
749
20.2
41.93°C
0.986
12.151V
5.064V
3.325V
5.1V
436.087
47.45°C
114.85V
50%
36.937A
4.939A
4.968A
1.768A
499.264
91.341%
745
20.0
42.12°C
0.987
12.149V
5.061V
3.321V
5.09V
546.593
48.21°C
114.83V
60%
44.445A
5.93A
5.968A
1.969A
599.801
90.782%
743
20.0
42.75°C
0.988
12.150V
5.059V
3.318V
5.079V
660.703
49.37°C
114.79V
70%
51.875A
6.922A
6.97A
2.17A
699.532
90.108%
830
23.4
43.3°C
0.989
12.152V
5.057V
3.314V
5.068V
776.319
50.37°C
114.77V
80%
59.373A
7.916A
7.972A
2.273A
799.568
89.319%
909
26.4
44.27°C
0.991
12.155V
5.055V
3.311V
5.059V
895.184
52.32°C
114.74V
90%
67.193A
8.412A
8.463A
2.376A
899.326
88.469%
1111
32.3
44.86°C
0.992
12.157V
5.052V
3.307V
5.051V
1016.55
53.93°C
114.71V
100%
74.823A
8.911A
8.988A
2.981A
999.356
87.544%
1302
37.7
45.69°C
0.993
12.158V
5.05V
3.304V
5.032V
1141.544
55.73°C
114.68V
110%
82.381A
9.907A
10.089A
2.985A
1099.987
86.472%
1551
42.5
46.53°C
0.993
12.159V
5.047V
3.3V
5.025V
1272.069
57.41°C
114.65V
CL1
0.115A
14.891A
14.894A
0A
126.303
83.525%
699
18.0
42.36°C
0.975
12.193V
5.058V
3.33V
5.138V
151.216
47.82°C
114.89V
CL2
0.115A
24.75A
0A
0A
126.418
82.119%
878
25.4
40.99°C
0.973
12.192V
5.052V
3.336V
5.145V
153.95
48.01°C
114.9V
CL3
0.114A
0A
24.77A
0A
83.876
75.015%
876
25.3
39.81°C
0.964
12.182V
5.075V
3.33V
5.139V
111.807
48.84°C
114.91V
CL4
82.275A
0A
0A
0A
999.938
88.227%
1210
34.8
56.81°C
0.992
12.153V
5.064V
3.31V
5.105V
1133.377
45.92°C
114.68V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.438A
1.972A
1.979A
0.975A
100.006
87.242%
0
<6.0
44.88°C
0.845
12.179V
5.071V
3.335V
5.131V
114.633
40.52°C
229.88V
20%
13.909A
2.959A
2.971A
1.172A
199.963
92.146%
0
<6.0
45.72°C
0.925
12.155V
5.069V
3.332V
5.12V
217.002
40.97°C
229.87V
30%
21.721A
3.454A
3.47A
1.37A
300.026
93.273%
0
<6.0
46.39°C
0.952
12.153V
5.067V
3.328V
5.109V
321.661
41.31°C
229.86V
40%
29.504A
3.95A
3.97A
1.569A
399.659
93.317%
749
20.2
41.77°C
0.964
12.150V
5.064V
3.325V
5.099V
428.274
47.31°C
229.85V
50%
36.949A
4.94A
4.969A
1.769A
499.364
93.246%
745
20.0
42.45°C
0.971
12.148V
5.061V
3.321V
5.089V
535.536
48.46°C
229.83V
60%
44.454A
5.932A
5.97A
1.969A
599.909
92.911%
742
19.9
43.09°C
0.976
12.149V
5.058V
3.317V
5.078V
645.68
49.79°C
229.82V
70%
51.890A
6.924A
6.972A
2.171A
699.644
92.539%
829
23.4
43.25°C
0.979
12.151V
5.056V
3.314V
5.067V
756.055
50.26°C
229.81V
80%
59.390A
7.918A
7.975A
2.274A
799.68
92.037%
907
26.4
43.86°C
0.981
12.153V
5.054V
3.31V
5.059V
868.864
52.07°C
229.8V
90%
67.212A
8.414A
8.466A
2.376A
899.417
91.548%
1073
31.4
44.71°C
0.983
12.155V
5.052V
3.307V
5.05V
982.46
53.75°C
229.79V
100%
74.836A
8.913A
8.989A
2.982A
999.431
90.983%
1254
36.2
45.34°C
0.984
12.157V
5.05V
3.303V
5.031V
1098.479
55.39°C
229.78V
110%
82.395A
9.908A
10.09A
2.985A
1100.038
90.372%
1523
42.3
46.98°C
0.985
12.157V
5.047V
3.3V
5.025V
1217.229
57.91°C
229.76V
CL1
0.115A
14.891A
14.895A
0A
126.306
84.649%
697
17.5
44°C
0.885
12.193V
5.058V
3.33V
5.138V
149.208
49.49°C
229.88V
CL2
0.115A
24.748A
0A
0A
126.419
83.205%
878
25.4
42.81°C
0.888
12.192V
5.052V
3.336V
5.145V
151.936
49.83°C
229.87V
CL3
0.114A
0A
24.77A
0A
83.876
75.823%
876
25.3
41.56°C
0.838
12.184V
5.076V
3.33V
5.139V
110.612
50.61°C
229.88V
CL4
82.274A
0A
0A
0A
999.889
91.606%
1181
34.0
44.66°C
0.983
12.153V
5.064V
3.31V
5.105V
1091.506
55.61°C
229.77V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.226A
0.493A
0.494A
0.194A
19.99
74.169%
0
<6.0
39.81°C
0.828
12.104V
5.075V
3.339V
5.154V
26.956
36.72°C
114.93V
40W
2.699A
0.69A
0.692A
0.291A
39.991
80.771%
0
<6.0
40.75°C
0.916
12.109V
5.074V
3.339V
5.151V
49.515
37.41°C
114.92V
60W
4.172A
0.886A
0.889A
0.388A
59.99
83.295%
0
<6.0
42.34°C
0.946
12.108V
5.074V
3.338V
5.147V
72.018
38.54°C
114.92V
80W
5.609A
1.084A
1.087A
0.486A
79.929
84.798%
0
<6.0
43.5°C
0.959
12.177V
5.073V
3.337V
5.144V
94.263
39.54°C
114.9V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.228A
0.493A
0.494A
0.194A
20.001
74.667%
0
<6.0
40.53°C
0.462
12.103V
5.075V
3.339V
5.154V
26.79
37.43°C
229.89V
40W
2.700A
0.69A
0.692A
0.291A
40.001
81.211%
0
<6.0
41.13°C
0.646
12.106V
5.074V
3.338V
5.151V
49.251
37.87°C
229.88V
60W
4.174A
0.887A
0.89A
0.389A
60
83.994%
0
<6.0
41.93°C
0.745
12.106V
5.073V
3.338V
5.147V
71.433
38.44°C
229.88V
80W
5.611A
1.084A
1.088A
0.486A
79.953
85.547%
0
<6.0
42.99°C
0.805
12.176V
5.073V
3.337V
5.144V
93.462
39.26°C
229.88V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.52mV
7.00mV
13.19mV
10.34mV
Pass
20% Load
17.37mV
6.08mV
9.67mV
7.83mV
Pass
30% Load
11.74mV
6.08mV
10.07mV
8.80mV
Pass
40% Load
11.51mV
7.81mV
11.45mV
21.70mV
Pass
50% Load
10.90mV
8.12mV
11.55mV
22.77mV
Pass
60% Load
11.21mV
8.33mV
12.68mV
23.44mV
Pass
70% Load
11.67mV
8.73mV
12.89mV
23.85mV
Pass
80% Load
12.33mV
9.04mV
15.60mV
23.23mV
Pass
90% Load
13.10mV
9.65mV
16.11mV
24.62mV
Pass
100% Load
19.39mV
12.24mV
19.17mV
25.99mV
Pass
110% Load
20.23mV
14.51mV
21.56mV
27.00mV
Pass
Crossload1
27.07mV
10.04mV
16.68mV
22.20mV
Pass
Crossload2
26.02mV
10.01mV
13.19mV
20.88mV
Pass
Crossload3
8.08mV
7.86mV
19.74mV
21.44mV
Pass
Crossload4
18.85mV
11.31mV
16.58mV
26.33mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.98mV
6.69mV
11.30mV
9.42mV
Pass
20% Load
18.81mV
5.92mV
9.10mV
7.52mV
Pass
30% Load
12.46mV
6.23mV
9.82mV
8.55mV
Pass
40% Load
12.15mV
8.07mV
11.00mV
19.81mV
Pass
50% Load
11.23mV
7.46mV
11.20mV
20.47mV
Pass
60% Load
11.38mV
7.71mV
11.15mV
21.39mV
Pass
70% Load
11.79mV
7.92mV
12.88mV
21.39mV
Pass
80% Load
12.05mV
8.79mV
14.42mV
21.80mV
Pass
90% Load
12.28mV
9.40mV
16.16mV
22.21mV
Pass
100% Load
19.99mV
12.94mV
19.59mV
25.75mV
Pass
110% Load
20.65mV
14.83mV
21.49mV
26.93mV
Pass
Crossload1
31.77mV
9.74mV
15.90mV
21.61mV
Pass
Crossload2
26.63mV
10.01mV
12.88mV
20.57mV
Pass
Crossload3
7.62mV
7.51mV
18.26mV
21.29mV
Pass
Crossload4
20.16mV
12.71mV
18.60mV
26.76mV
Pass
The results above are not used in the certification process
Seasonic Vertex GX-1000
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted