Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
16AWG
No
4+4 pin EPS12V (700mm)
2
2
16AWG
No
6+2 pin PCIe (550mm+150mm)
2
4
16-18AWG
No
12+4 pin PCIe (600mm) (600W)
1
1
16-26AWG
No
SATA (500mm+150mm+150mm+150mm)
2
8
18AWG
No
4-pin Molex (500mm+150mm+150mm) / FDD (+150mm)
1
3 / 1
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
89.645%
Average Noise Output (>1450 Load Combinations)
31.85dBA
Average PF (>1450 Load Combinations)
0.977
Efficiency With 10W (≤500W) or 2% (>500W) Load
69.955%
Standby Power Consumption
0.0496W
12V Ripple (Full Load)
48.97mV
5V Ripple (Full Load)
45.02mV
3.3V Ripple (Full Load)
51.83mV
5VSB Ripple (Full Load)
54.22mV
12V Load Regulation
1.01%
5V Load Regulation
0.46%
3.3V Load Regulation
0.80%
5VSB Load Regulation
3.40%
Inrush Current
60.510A
效率評比
PLATINUM
噪音評比
Standard
Average Efficiency (>1450 load combinations)
91.636%
Average Noise Output (>1450 Load Combinations)
40.13dBA
Average PF (>1450 Load Combinations)
0.944
Efficiency With 10W (≤500W) or 2% (>500W) Load
65.312%
Standby Power Consumption
0.1219W
12V Ripple (Full Load)
29.13mV
5V Ripple (Full Load)
14.16mV
3.3V Ripple (Full Load)
26.27mV
5VSB Ripple (Full Load)
25.98mV
12V Load Regulation
0.48%
5V Load Regulation
0.78%
3.3V Load Regulation
1.17%
5VSB Load Regulation
3.71%
Inrush Current
93.900A
12V Transient Response (200%)
11.30V
5V Transient Response (200%)
4.914V
3.3V Transient Response (200%)
3.155V
5VSB Transient Response (200%)
4.974V
Hold-Up Time & Power Ok Signal
23.80ms
AC Loss to PWR_OK Hold Up Time
18.80ms
PWR_OK Inactive to DC Loss Delay
5.00ms
PSU Timings: T1 (20% / 100%)
93.0ms
92.0ms
PSU Timings: T3 (20% / 100%)
125.0ms
125.0ms
12V OCP (29.3°C / 41.8°C)
134.00A (134.00%), 12.1175V
132.20A (132.20%), 12.1405V
5V OCP (29.3°C / 41.8°C)
29.7A (148.50%), 5.031V
29.6A (148.00%), 5.03V
3.3V OCP (29.3°C / 41.8°C)
29.4A (147.00%), 3.34V
29.3A (146.50%), 3.345V
5VSB OCP (29.3°C / 41.8°C)
6.5A (216.67%), 4.972V
6.4A (213.33%), 4.969V
OPP (28.95°C / 39.81°C)
141.51%
125.18%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
23.8
AC Loss to PWR_OK Hold Up Time (ms)
18.8
PWR_OK Inactive to DC Loss Delay (ms)
5
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.88 V
114.78 V
113.85 V
114.97 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.97 Hz
59.40 Hz
60.03 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.421
1.419
1.340
1.424
1.490
PASS
Mains Voltage THD:
0.15 %
0.11 %
N/A
0.29 %
2.00 %
PASS
Real Power:
0.050 W
0.001 W
N/A
0.086 W
N/A
N/A
Apparent Power:
7.935 W
7.905 W
N/A
7.985 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.87 V
229.79 V
227.70 V
229.92 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.418
1.417
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.122 W
0.079 W
N/A
0.179 W
N/A
N/A
Apparent Power:
27.851 W
27.810 W
N/A
27.896 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input