This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
55.724%
0.023
5.155V
0.236W
114.87V
2
0.09A
0.464W
71.162%
0.062
5.153V
0.652W
114.87V
3
0.55A
2.823W
84.004%
0.247
5.133V
3.361W
114.87V
4
1A
5.114W
83.931%
0.333
5.114V
6.093W
114.87V
5
1.5A
7.64W
83.704%
0.383
5.092V
9.127W
114.87V
6
3A
15.085W
81.898%
0.449
5.028V
18.419W
114.86V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
55.808%
0.012
5.155V
0.417W
229.95V
2
0.09A
0.464W
66.847%
0.02
5.153V
0.695W
229.95V
3
0.55A
2.823W
80.363%
0.096
5.133V
3.515W
229.95V
4
1A
5.114W
82.052%
0.159
5.114V
6.233W
229.95V
5
1.5A
7.639W
82.324%
0.214
5.092V
9.28W
229.95V
6
3A
15.085W
82.793%
0.313
5.028V
18.22W
229.95V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
8.104A
1.977A
1.989A
0.98A
119.972
87.252%
995
22.5
40.17°C
0.903
12.138V
5.059V
3.317V
5.103V
137.503
44.37°C
114.84V
20%
17.242A
2.973A
2.997A
1.18A
239.923
91.092%
996
22.5
40.89°C
0.952
12.122V
5.045V
3.303V
5.084V
263.379
45.42°C
114.8V
30%
26.678A
3.477A
3.509A
1.382A
359.074
91.252%
998
22.5
41.22°C
0.939
12.108V
5.033V
3.291V
5.066V
364.232
46.28°C
107.51V
40%
36.238A
3.983A
4.025A
1.585A
479.469
91.035%
1033
23.4
41.7°C
0.982
12.094V
5.021V
3.279V
5.046V
526.685
47.21°C
114.72V
50%
45.427A
4.993A
5.053A
1.79A
599.224
90.391%
1574
35.0
42.17°C
0.988
12.080V
5.008V
3.265V
5.027V
662.925
48.26°C
114.68V
60%
54.705A
6.008A
6.09A
1.997A
719.755
89.678%
1965
41.0
42.81°C
0.991
12.064V
4.994V
3.251V
5.007V
802.601
49.34°C
114.64V
70%
63.941A
7.031A
7.139A
2.206A
839.482
88.866%
2023
41.7
43.36°C
0.993
12.048V
4.978V
3.236V
4.986V
944.66
50.39°C
114.58V
80%
73.269A
8.06A
8.199A
2.314A
959.477
87.956%
2024
41.7
43.73°C
0.995
12.032V
4.962V
3.22V
4.969V
1090.853
52.02°C
114.54V
90%
82.948A
8.586A
8.733A
2.424A
1079.291
87.008%
2024
41.7
44.68°C
0.995
12.017V
4.949V
3.206V
4.951V
1240.443
53.76°C
114.49V
100%
92.468A
9.119A
9.307A
3.056A
1199.332
85.835%
2021
41.7
45.65°C
0.995
12.000V
4.935V
3.191V
4.909V
1397.253
55.66°C
114.44V
110%
101.958A
10.168A
10.493A
3.066A
1319.935
84.298%
2023
41.7
46.77°C
0.991
11.982V
4.917V
3.173V
4.892V
1565.803
57.68°C
114.4V
CL1
1.980A
12.433A
12.553A
0.489A
129.409
81.297%
995
22.5
39.98°C
0.918
12.129V
4.987V
3.258V
5.108V
159.18
45.43°C
114.83V
CL2
1.978A
15.346A
1.003A
0.488A
106.505
81.937%
1002
22.6
40.23°C
0.898
12.137V
4.998V
3.29V
5.118V
129.985
47.31°C
114.84V
CL3
1.978A
0.995A
14.597A
0.489A
79.299
77.386%
993
22.4
40.33°C
0.881
12.129V
5.027V
3.274V
5.117V
102.472
49.39°C
114.85V
CL4
98.979A
1.002A
1.019A
0.496A
1199.512
86.662%
2033
41.8
45.07°C
0.996
12.010V
4.991V
3.237V
5.038V
1384.15
55.98°C
114.45V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
8.106A
1.977A
1.99A
0.98A
119.989
87.366%
996
22.5
40.3°C
0.818
12.138V
5.058V
3.317V
5.101V
137.344
44.59°C
229.93V
20%
17.245A
2.974A
2.997A
1.181A
239.947
92.037%
996
22.5
40.58°C
0.895
12.122V
5.044V
3.303V
5.082V
260.705
45.11°C
229.91V
30%
26.686A
3.478A
3.51A
1.382A
359.15
92.905%
998
22.5
41.14°C
0.929
12.107V
5.033V
3.291V
5.064V
386.583
46.14°C
229.89V
40%
36.246A
3.984A
4.026A
1.586A
479.54
93.019%
1016
23.0
41.84°C
0.949
12.093V
5.021V
3.279V
5.044V
515.529
47.36°C
229.88V
50%
45.436A
4.994A
5.055A
1.791A
599.29
92.553%
1626
35.9
42.33°C
0.961
12.078V
5.007V
3.264V
5.024V
647.513
48.35°C
229.85V
60%
54.716A
6.01A
6.092A
1.998A
719.817
92.028%
1965
41.0
42.8°C
0.968
12.063V
4.993V
3.25V
5.004V
782.17
49.31°C
229.84V
70%
63.953A
7.033A
7.141A
2.207A
839.54
91.492%
2024
41.7
43.18°C
0.974
12.047V
4.978V
3.235V
4.984V
917.608
50.22°C
229.82V
80%
73.279A
8.059A
8.197A
2.315A
959.479
90.966%
2030
41.7
43.77°C
0.978
12.031V
4.963V
3.22V
4.968V
1054.775
51.81°C
229.8V
90%
82.961A
8.588A
8.735A
2.425A
1079.307
90.261%
2027
41.7
44.22°C
0.981
12.015V
4.949V
3.205V
4.95V
1195.765
53.24°C
229.77V
100%
92.482A
9.12A
9.309A
3.057A
1199.345
89.43%
2028
41.7
45.74°C
0.983
11.998V
4.934V
3.19V
4.907V
1341.087
55.83°C
229.76V
110%
101.976A
10.171A
10.5A
3.067A
1319.964
88.401%
2025
41.7
46.79°C
0.985
11.980V
4.916V
3.171V
4.891V
1493.163
57.69°C
229.74V
CL1
1.980A
12.437A
12.562A
0.489A
129.414
82.269%
998
22.5
41.43°C
0.837
12.128V
4.985V
3.256V
5.108V
157.305
46.89°C
229.93V
CL2
1.978A
15.35A
1.003A
0.489A
106.511
81.859%
1003
22.6
40.57°C
0.811
12.136V
4.997V
3.289V
5.117V
130.113
47.66°C
229.94V
CL3
1.980A
0.995A
14.597A
0.489A
79.302
78.072%
990
22.3
40.3°C
0.765
12.128V
5.027V
3.274V
5.117V
101.576
49.38°C
229.94V
CL4
98.989A
1.002A
1.019A
0.496A
1199.529
90.192%
2039
41.8
45.3°C
0.983
12.009V
4.991V
3.237V
5.038V
1329.98
56.23°C
229.75V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.222A
0.493A
0.495A
0.194A
19.997
54.326%
990
22.3
36.58°C
0.783
12.142V
5.074V
3.331V
5.143V
36.81
39.71°C
114.87V
40W
2.694A
0.69A
0.694A
0.292A
39.997
76.028%
992
22.4
37.19°C
0.819
12.137V
5.072V
3.329V
5.137V
52.61
40.49°C
114.87V
60W
4.164A
0.888A
0.893A
0.39A
59.997
81.391%
994
22.4
38.48°C
0.856
12.135V
5.07V
3.326V
5.131V
73.716
42.26°C
114.86V
80W
5.630A
1.086A
1.092A
0.488A
79.94
83.097%
994
22.4
39.29°C
0.877
12.134V
5.067V
3.323V
5.125V
96.202
43.25°C
114.85V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.224A
0.492A
0.495A
0.194A
19.999
55.078%
986
22.2
36.66°C
0.471
12.135V
5.079V
3.336V
5.144V
36.315
39.75°C
229.95V
40W
2.694A
0.69A
0.694A
0.292A
39.999
76.168%
992
22.4
37.59°C
0.586
12.136V
5.073V
3.33V
5.138V
52.513
40.91°C
229.95V
60W
4.164A
0.887A
0.892A
0.39A
59.997
80.822%
993
22.4
38.26°C
0.69
12.133V
5.072V
3.328V
5.132V
74.233
41.76°C
229.94V
80W
5.630A
1.085A
1.092A
0.488A
79.94
83.791%
994
22.4
39.11°C
0.753
12.134V
5.067V
3.323V
5.125V
95.406
42.99°C
229.94V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
14.9 mV
20.3 mV
25.5 mV
10.7 mV
Pass
20% Load
17.1 mV
20.2 mV
19.0 mV
12.9 mV
Pass
30% Load
16.6 mV
20.8 mV
19.1 mV
13.3 mV
Pass
40% Load
17.6 mV
22.9 mV
19.4 mV
13.0 mV
Pass
50% Load
18.5 mV
24.1 mV
19.3 mV
13.8 mV
Pass
60% Load
20.8 mV
26.0 mV
20.6 mV
14.9 mV
Pass
70% Load
21.2 mV
26.7 mV
21.6 mV
13.6 mV
Pass
80% Load
25.0 mV
30.6 mV
22.6 mV
13.2 mV
Pass
90% Load
24.6 mV
33.0 mV
24.5 mV
14.1 mV
Pass
100% Load
30.4 mV
38.3 mV
28.0 mV
24.6 mV
Pass
110% Load
37.2 mV
43.6 mV
31.5 mV
24.4 mV
Pass
Crossload 1
22.3 mV
39.0 mV
27.3 mV
9.4 mV
Pass
Crossload 2
14.0 mV
17.2 mV
27.4 mV
8.9 mV
Pass
Crossload 3
19.3 mV
58.4 mV
18.0 mV
8.7 mV
Fail
Crossload 4
29.7 mV
22.1 mV
23.4 mV
17.8 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.0 mV
17.7 mV
22.9 mV
8.6 mV
Pass
20% Load
14.4 mV
17.9 mV
16.7 mV
11.0 mV
Pass
30% Load
15.9 mV
19.4 mV
17.2 mV
12.1 mV
Pass
40% Load
16.9 mV
20.8 mV
18.6 mV
12.4 mV
Pass
50% Load
18.5 mV
22.9 mV
20.1 mV
13.8 mV
Pass
60% Load
19.6 mV
25.3 mV
20.1 mV
14.7 mV
Pass
70% Load
20.9 mV
26.5 mV
21.1 mV
13.8 mV
Pass
80% Load
22.2 mV
29.8 mV
22.5 mV
16.0 mV
Pass
90% Load
23.7 mV
31.1 mV
21.8 mV
13.7 mV
Pass
100% Load
27.0 mV
34.9 mV
23.8 mV
20.3 mV
Pass
110% Load
29.2 mV
36.2 mV
24.0 mV
23.2 mV
Pass
Crossload 1
20.9 mV
35.5 mV
24.8 mV
7.5 mV
Pass
Crossload 2
11.7 mV
15.2 mV
23.9 mV
6.8 mV
Pass
Crossload 3
16.8 mV
56.7 mV
16.3 mV
6.9 mV
Fail
Crossload 4
25.8 mV
20.6 mV
20.8 mV
15.7 mV
Pass
The results above are not used in the certification process
Aqirys Quasar 1200W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case