Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (610mm)
1
1
18-22AWG
No
4+4 pin EPS12V (600mm)
1
1
18AWG
No
8 pin EPS12V (600mm)
1
1
18AWG
No
6+2 pin PCIe (550mm)
3
3
16-18AWG
No
12+4 pin PCIe (650mm) (600W)
1
1
16-28AWG
No
SATA (500mm+120mm+120mm+120mm)
3
12
18AWG
No
4-pin Molex (500mm+120mm+120mm+120mm)
1
4
18AWG
No
AC Power Cord (1370mm) - C13 coupler
1
1
17AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
89.713%
Average Noise Output (>1450 Load Combinations)
26.75dBA
Average PF (>1450 Load Combinations)
0.993
Efficiency With 10W (≤500W) or 2% (>500W) Load
77.523%
Standby Power Consumption
0.0720W
12V Ripple (Full Load)
34.23mV
5V Ripple (Full Load)
15.66mV
3.3V Ripple (Full Load)
17.57mV
5VSB Ripple (Full Load)
12.31mV
12V Load Regulation
0.80%
5V Load Regulation
2.05%
3.3V Load Regulation
2.85%
5VSB Load Regulation
4.00%
Inrush Current
Too low to detect
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
91.874%
Average Noise Output (>1450 Load Combinations)
26.73dBA
Average PF (>1450 Load Combinations)
0.980
Efficiency With 10W (≤500W) or 2% (>500W) Load
81.529%
Standby Power Consumption
0.1517W
12V Ripple (Full Load)
36.87mV
5V Ripple (Full Load)
16.48mV
3.3V Ripple (Full Load)
17.05mV
5VSB Ripple (Full Load)
11.44mV
12V Load Regulation
0.74%
5V Load Regulation
2.01%
3.3V Load Regulation
2.88%
5VSB Load Regulation
3.98%
Inrush Current
67.460A
12V Transient Response (200%)
11.21V
5V Transient Response (200%)
4.859V
3.3V Transient Response (200%)
3.162V
5VSB Transient Response (200%)
4.806V
Hold-Up Time & Power Ok Signal
25.00ms
AC Loss to PWR_OK Hold Up Time
21.50ms
PWR_OK Inactive to DC Loss Delay
3.50ms
PSU Timings: T1 (20% / 100%)
62.0ms
37.0ms
PSU Timings: T3 (20% / 100%)
125.0ms
121.0ms
OPP (27.28°C / 41.49°C)
136.83%
136.83%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
25
AC Loss to PWR_OK Hold Up Time (ms)
21.5
PWR_OK Inactive to DC Loss Delay (ms)
3.5
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.85 V
114.79 V
113.85 V
114.91 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.98 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.420
1.418
1.340
1.422
1.490
PASS
Mains Voltage THD:
0.15 %
0.10 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.072 W
0.015 W
N/A
0.107 W
N/A
N/A
Apparent Power:
10.948 W
10.929 W
N/A
10.977 W
N/A
N/A
Power Factor:
0.009
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.87 V
229.78 V
227.70 V
229.93 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.418
1.417
1.340
1.420
1.490
PASS
Mains Voltage THD:
0.14 %
0.10 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.152 W
0.117 W
N/A
0.182 W
N/A
N/A
Apparent Power:
36.809 W
36.785 W
N/A
36.836 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input