Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
16-20AWG
No
4+4 pin EPS12V (700mm)
1
1
16AWG
No
8 pin EPS12V (700mm)
1
1
16AWG
No
6+2 pin PCIe (650mm)
3
3
16-18AWG
No
12+4 pin PCIe (645mm) (600W)
1
1
16-24AWG
No
SATA (500mm+145mm+145mm+145mm)
3
12
18AWG
No
4-pin Molex (500mm+145mm+145mm+145mm)
1
4
18AWG
No
AC Power Cord (1415mm) - C13 coupler
1
1
14AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
GOLD
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
88.749%
Average Noise Output (>1450 Load Combinations)
25.41dBA
Average PF (>1450 Load Combinations)
0.987
Efficiency With 10W (≤500W) or 2% (>500W) Load
77.025%
Standby Power Consumption
0.0132W
12V Ripple (Full Load)
18.63mV
5V Ripple (Full Load)
7.83mV
3.3V Ripple (Full Load)
8.71mV
5VSB Ripple (Full Load)
9.78mV
12V Load Regulation
0.91%
5V Load Regulation
0.34%
3.3V Load Regulation
0.78%
5VSB Load Regulation
1.57%
Inrush Current
35.610A
Wirkungsgrad
GOLD
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
90.910%
Average Noise Output (>1450 Load Combinations)
25.44dBA
Average PF (>1450 Load Combinations)
0.963
Efficiency With 10W (≤500W) or 2% (>500W) Load
76.621%
Standby Power Consumption
0.0704W
12V Ripple (Full Load)
18.61mV
5V Ripple (Full Load)
10.75mV
3.3V Ripple (Full Load)
8.98mV
5VSB Ripple (Full Load)
8.47mV
12V Load Regulation
0.90%
5V Load Regulation
0.34%
3.3V Load Regulation
0.81%
5VSB Load Regulation
1.57%
Inrush Current
63.390A
12V Transient Response (200%)
11.58V
5V Transient Response (200%)
4.983V
3.3V Transient Response (200%)
3.233V
5VSB Transient Response (200%)
4.876V
Hold-Up Time & Power Ok Signal
25.60ms
AC Loss to PWR_OK Hold Up Time
24.20ms
PWR_OK Inactive to DC Loss Delay
1.40ms
PSU Timings: T1 (20% / 100%)
63.0ms
60.0ms
PSU Timings: T3 (20% / 100%)
131.0ms
131.0ms
OPP (27.22°C / 42.84°C)
121.50%
121.14%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
25.6
AC Loss to PWR_OK Hold Up Time (ms)
24.2
PWR_OK Inactive to DC Loss Delay (ms)
1.4
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.18 V
115.14 V
113.85 V
115.18 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.95 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.13 %
0.11 %
N/A
0.15 %
2.00 %
PASS
Real Power:
0.013 W
0.011 W
N/A
0.086 W
N/A
N/A
Apparent Power:
9.991 W
9.986 W
N/A
10.020 W
N/A
N/A
Power Factor:
0.001
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.38 V
230.34 V
227.70 V
230.40 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.14 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.070 W
0.061 W
N/A
0.084 W
N/A
N/A
Apparent Power:
33.435 W
33.422 W
N/A
33.445 W
N/A
N/A
Power Factor:
0.002
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input