Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
18-22AWG
No
4+4 pin EPS12V (650mm)
2
2
18AWG
No
6+2 pin PCIe (600mm)
3
3
18AWG
No
12+4 pin PCIe (700mm) (600W)
1
1
16-24AWG
No
SATA (450mm+145mm+145mm+145mm)
2
8
18AWG
No
4-pin Molex (450mm+145mm+145mm+145mm)
1
4
18AWG
No
AC Power Cord (1360mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
A-
Average Efficiency (>1450 load combinations)
89.251%
Average Noise Output (>1450 Load Combinations)
28.16dBA
Average PF (>1450 Load Combinations)
0.991
Efficiency With 10W (≤500W) or 2% (>500W) Load
69.023%
Standby Power Consumption
0.0416W
12V Ripple (Full Load)
32.16mV
5V Ripple (Full Load)
15.48mV
3.3V Ripple (Full Load)
17.26mV
5VSB Ripple (Full Load)
27.20mV
12V Load Regulation
0.26%
5V Load Regulation
0.63%
3.3V Load Regulation
1.12%
5VSB Load Regulation
4.76%
Inrush Current
30.930A
效率評比
PLATINUM
噪音評比
A-
Average Efficiency (>1450 load combinations)
91.653%
Average Noise Output (>1450 Load Combinations)
26.39dBA
Average PF (>1450 Load Combinations)
0.972
Efficiency With 10W (≤500W) or 2% (>500W) Load
69.873%
Standby Power Consumption
0.0858W
12V Ripple (Full Load)
33.24mV
5V Ripple (Full Load)
16.11mV
3.3V Ripple (Full Load)
15.86mV
5VSB Ripple (Full Load)
26.71mV
12V Load Regulation
0.29%
5V Load Regulation
0.57%
3.3V Load Regulation
1.12%
5VSB Load Regulation
4.76%
Inrush Current
53.570A
12V Transient Response (200%)
11.47V
5V Transient Response (200%)
4.979V
3.3V Transient Response (200%)
3.199V
5VSB Transient Response (200%)
4.913V
Hold-Up Time & Power Ok Signal
20.50ms
AC Loss to PWR_OK Hold Up Time
17.80ms
PWR_OK Inactive to DC Loss Delay
2.70ms
PSU Timings: T1 (20% / 100%)
61.0ms
62.0ms
PSU Timings: T3 (20% / 100%)
123.0ms
126.0ms
OPP (28.23°C / 43.11°C)
140.71%
134.37%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
20.5
AC Loss to PWR_OK Hold Up Time (ms)
17.8
PWR_OK Inactive to DC Loss Delay (ms)
2.7
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.06 V
115.02 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.042 W
0.006 W
N/A
0.066 W
N/A
N/A
Apparent Power:
6.455 W
6.385 W
N/A
6.528 W
N/A
N/A
Power Factor:
0.009
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.00 V
230.90 V
227.70 V
231.06 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.086 W
0.074 W
N/A
0.106 W
N/A
N/A
Apparent Power:
21.561 W
21.383 W
N/A
21.738 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input