Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
16-18AWG
No
4+4 pin EPS12V (650mm)
2
2
16AWG
No
6+2 pin PCIe (750mm)
3
3
16-18AWG
No
12+4 pin PCIe (715mm) (600W)
1
1
16-24AWG
No
SATA (450mm+145mm+145mm+145mm)
2
8
18AWG
No
SATA (450mm+145mm) / 4-pin Molex (+150mm+145mm)
1
2 / 2
18AWG
No
AC Power Cord (1360mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
GOLD
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
88.936%
Average Noise Output (>1450 Load Combinations)
32.95dBA
Average PF (>1450 Load Combinations)
0.990
Efficiency With 10W (≤500W) or 2% (>500W) Load
69.682%
Standby Power Consumption
0.0444W
12V Ripple (Full Load)
23.22mV
5V Ripple (Full Load)
21.52mV
3.3V Ripple (Full Load)
24.78mV
5VSB Ripple (Full Load)
14.98mV
12V Load Regulation
0.47%
5V Load Regulation
0.71%
3.3V Load Regulation
1.03%
5VSB Load Regulation
3.12%
Inrush Current
27.240A
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
91.415%
Average Noise Output (>1450 Load Combinations)
32.12dBA
Average PF (>1450 Load Combinations)
0.961
Efficiency With 10W (≤500W) or 2% (>500W) Load
70.990%
Standby Power Consumption
0.0987W
12V Ripple (Full Load)
23.11mV
5V Ripple (Full Load)
21.72mV
3.3V Ripple (Full Load)
24.01mV
5VSB Ripple (Full Load)
13.81mV
12V Load Regulation
0.48%
5V Load Regulation
0.71%
3.3V Load Regulation
1.03%
5VSB Load Regulation
3.10%
Inrush Current
59.260A
12V Transient Response (200%)
11.59V
5V Transient Response (200%)
4.985V
3.3V Transient Response (200%)
3.231V
5VSB Transient Response (200%)
4.981V
Hold-Up Time & Power Ok Signal
20.90ms
AC Loss to PWR_OK Hold Up Time
17.70ms
PWR_OK Inactive to DC Loss Delay
3.20ms
PSU Timings: T1 (20% / 100%)
60.0ms
59.0ms
PSU Timings: T3 (20% / 100%)
124.0ms
122.0ms
OPP (26.56°C / 42.71°C)
132.97%
122.13%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
20.9
AC Loss to PWR_OK Hold Up Time (ms)
17.7
PWR_OK Inactive to DC Loss Delay (ms)
3.2
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.85 V
114.79 V
113.85 V
114.88 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.98 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.419
1.418
1.340
1.420
1.490
PASS
Mains Voltage THD:
0.14 %
0.12 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.044 W
0.011 W
N/A
0.068 W
N/A
N/A
Apparent Power:
7.804 W
7.786 W
N/A
7.823 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.86 V
229.79 V
227.70 V
229.90 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.418
1.417
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.13 %
0.11 %
N/A
0.15 %
2.00 %
PASS
Real Power:
0.099 W
0.081 W
N/A
0.126 W
N/A
N/A
Apparent Power:
26.405 W
26.366 W
N/A
26.444 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input