Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (495mm)
1
1
16-22AWG
No
4+4 pin EPS12V (550mm)
1
1
16AWG
No
8 pin EPS12V (550mm)
1
1
16AWG
No
6+2 pin PCIe (550mm)
4
4
16AWG
No
12+4 pin PCIe (720mm) (600W)
1
1
16-26AWG
No
2x SATA (400mm+125mm)
1
4
18AWG
No
SATA (305mm+15mm+15mm+15mm)
1
4
18AWG
No
SATA (400mm+150mm+150mm+150mm)
2
8
18AWG
No
4-pin Molex (495mm+150mm+150mm+150mm)
1
4
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
89.555%
Average Noise Output (>1450 Load Combinations)
25.82dBA
Average PF (>1450 Load Combinations)
0.989
Efficiency With 10W (≤500W) or 2% (>500W) Load
69.232%
Standby Power Consumption
0.0434W
12V Ripple (Full Load)
33.08mV
5V Ripple (Full Load)
15.68mV
3.3V Ripple (Full Load)
12.43mV
5VSB Ripple (Full Load)
15.62mV
12V Load Regulation
0.13%
5V Load Regulation
0.70%
3.3V Load Regulation
0.60%
5VSB Load Regulation
1.88%
Inrush Current
12.890A
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
91.691%
Average Noise Output (>1450 Load Combinations)
25.56dBA
Average PF (>1450 Load Combinations)
0.967
Efficiency With 10W (≤500W) or 2% (>500W) Load
68.443%
Standby Power Consumption
0.0959W
12V Ripple (Full Load)
33.27mV
5V Ripple (Full Load)
15.31mV
3.3V Ripple (Full Load)
12.28mV
5VSB Ripple (Full Load)
15.61mV
12V Load Regulation
0.45%
5V Load Regulation
0.70%
3.3V Load Regulation
0.63%
5VSB Load Regulation
1.90%
Inrush Current
18.850A
12V Transient Response (200%)
11.79V
5V Transient Response (200%)
4.905V
3.3V Transient Response (200%)
3.231V
5VSB Transient Response (200%)
4.944V
Hold-Up Time & Power Ok Signal
21.90ms
AC Loss to PWR_OK Hold Up Time
19.50ms
PWR_OK Inactive to DC Loss Delay
2.40ms
PSU Timings: T1 (20% / 100%)
62.0ms
61.0ms
PSU Timings: T3 (20% / 100%)
124.0ms
125.0ms
OPP (30.18°C / 43.65°C)
150.11%
134.10%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
21.9
AC Loss to PWR_OK Hold Up Time (ms)
19.5
PWR_OK Inactive to DC Loss Delay (ms)
2.4
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.06 V
115.02 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.93 Hz
59.40 Hz
60.03 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.043 W
0.008 W
N/A
0.067 W
N/A
N/A
Apparent Power:
7.102 W
6.971 W
N/A
7.241 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.00 V
230.89 V
227.70 V
231.06 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.096 W
0.084 W
N/A
0.128 W
N/A
N/A
Apparent Power:
23.436 W
23.221 W
N/A
23.647 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input