SATA (480mm+120mm+120mm+120mm) / 4-pin Molex (+120mm)
2
8 / 2
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
GOLD
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
88.379%
Average Noise Output (>1450 Load Combinations)
31.26dBA
Average PF (>1450 Load Combinations)
0.979
Efficiency With 10W (≤500W) or 2% (>500W) Load
65.952%
Standby Power Consumption
0.0383W
12V Ripple (Full Load)
49.77mV
5V Ripple (Full Load)
33.61mV
3.3V Ripple (Full Load)
38.15mV
5VSB Ripple (Full Load)
50.37mV
12V Load Regulation
0.64%
5V Load Regulation
0.84%
3.3V Load Regulation
0.84%
5VSB Load Regulation
4.21%
Inrush Current
32.670A
效率評比
GOLD
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
90.494%
Average Noise Output (>1450 Load Combinations)
30.43dBA
Average PF (>1450 Load Combinations)
0.941
Efficiency With 10W (≤500W) or 2% (>500W) Load
68.078%
Standby Power Consumption
0.1068W
12V Ripple (Full Load)
50.96mV
5V Ripple (Full Load)
34.52mV
3.3V Ripple (Full Load)
44.64mV
5VSB Ripple (Full Load)
48.78mV
12V Load Regulation
0.64%
5V Load Regulation
0.78%
3.3V Load Regulation
0.78%
5VSB Load Regulation
4.02%
Inrush Current
64.840A
12V Transient Response (200%)
11.20V
5V Transient Response (200%)
4.878V
3.3V Transient Response (200%)
3.179V
5VSB Transient Response (200%)
4.885V
Hold-Up Time & Power Ok Signal
15.20ms
AC Loss to PWR_OK Hold Up Time
14.00ms
PWR_OK Inactive to DC Loss Delay
1.20ms
PSU Timings: T1 (20% / 100%)
25.0ms
25.0ms
PSU Timings: T3 (20% / 100%)
127.0ms
127.0ms
12V OCP (29.8°C / 41.3°C)
105.40A (126.53%), 12.023V
101.60A (121.97%), 12.038V
5V OCP (29.8°C / 41.3°C)
28.1A (140.50%), 4.997V
26.7A (133.50%), 4.999V
3.3V OCP (29.8°C / 41.3°C)
28.7A (143.50%), 3.318V
28.1A (140.50%), 3.318V
5VSB OCP (29.8°C / 41.3°C)
3.9A (130.00%), 5.003V
4.1A (136.67%), 4.986V
OPP (29.00°C / 41.89°C)
125.91%
115.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
15.2
AC Loss to PWR_OK Hold Up Time (ms)
14
PWR_OK Inactive to DC Loss Delay (ms)
1.2
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.08 V
115.04 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.038 W
-0.004 W
N/A
0.074 W
N/A
N/A
Apparent Power:
10.345 W
10.234 W
N/A
10.468 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.00 V
230.90 V
227.70 V
231.07 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.107 W
0.067 W
N/A
0.179 W
N/A
N/A
Apparent Power:
35.029 W
34.756 W
N/A
35.297 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input