Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
16-22AWG
No
4+4 pin EPS12V (700mm)
2
2
16AWG
No
6+2 pin PCIe (600mm)
3
3
16AWG
No
12+4 pin PCIe (650mm) (600W)
1
1
16-24AWG
No
SATA (455mm+120mm+120mm+120mm)
2
8
18AWG
No
4-pin Molex (450mm+120mm+120mm+120mm)
1
4
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
89.791%
Average Noise Output (>1450 Load Combinations)
29.31dBA
Average PF (>1450 Load Combinations)
0.991
Efficiency With 10W (≤500W) or 2% (>500W) Load
71.566%
Standby Power Consumption
0.0567W
12V Ripple (Full Load)
52.36mV
5V Ripple (Full Load)
42.51mV
3.3V Ripple (Full Load)
39.12mV
5VSB Ripple (Full Load)
33.67mV
12V Load Regulation
0.32%
5V Load Regulation
0.51%
3.3V Load Regulation
1.42%
5VSB Load Regulation
3.81%
Inrush Current
27.420A
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
92.043%
Average Noise Output (>1450 Load Combinations)
29.31dBA
Average PF (>1450 Load Combinations)
0.971
Efficiency With 10W (≤500W) or 2% (>500W) Load
71.021%
Standby Power Consumption
0.0899W
12V Ripple (Full Load)
53.42mV
5V Ripple (Full Load)
44.95mV
3.3V Ripple (Full Load)
40.78mV
5VSB Ripple (Full Load)
36.61mV
12V Load Regulation
0.30%
5V Load Regulation
0.49%
3.3V Load Regulation
1.39%
5VSB Load Regulation
3.79%
Inrush Current
52.560A
12V Transient Response (200%)
11.22V
5V Transient Response (200%)
4.907V
3.3V Transient Response (200%)
3.155V
5VSB Transient Response (200%)
4.873V
Hold-Up Time & Power Ok Signal
21.10ms
AC Loss to PWR_OK Hold Up Time
18.10ms
PWR_OK Inactive to DC Loss Delay
3.00ms
PSU Timings: T1 (20% / 100%)
61.0ms
61.0ms
PSU Timings: T3 (20% / 100%)
119.0ms
121.0ms
12V OCP (26.5°C / 42.7°C)
128.00A (128.00%), 12.035V
126.00A (126.00%), 12.038V
5V OCP (26.5°C / 42.7°C)
27.8A (139.00%), 5.071V
26.7A (133.50%), 5.079V
3.3V OCP (26.5°C / 42.7°C)
29.6A (148.00%), 3.323V
28.9A (144.50%), 3.323V
5VSB OCP (26.5°C / 42.7°C)
4A (133.33%), 5.044V
3.9A (130.00%), 5.04V
OPP (27.14°C / 42.78°C)
135.93%
131.26%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
21.1
AC Loss to PWR_OK Hold Up Time (ms)
18.1
PWR_OK Inactive to DC Loss Delay (ms)
3
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.84 V
114.78 V
113.85 V
114.89 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.95 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.420
1.419
1.340
1.422
1.490
PASS
Mains Voltage THD:
0.15 %
0.10 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.057 W
0.050 W
N/A
0.063 W
N/A
N/A
Apparent Power:
6.830 W
6.814 W
N/A
6.848 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.85 V
229.79 V
227.70 V
229.93 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.418
1.417
1.340
1.420
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.090 W
0.076 W
N/A
0.122 W
N/A
N/A
Apparent Power:
23.594 W
23.564 W
N/A
23.617 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input