Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
16-22AWG
No
4+4 pin EPS12V (700mm)
2
2
16AWG
No
6+2 pin PCIe (600mm)
3
3
16AWG
No
12+4 pin PCIe (650mm) (600W)
1
1
16-24AWG
No
SATA (455mm+120mm+120mm+120mm)
1
4
18AWG
No
4-pin Molex (450mm+120mm+120mm+120mm)
1
4
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
A
Average Efficiency (>1450 load combinations)
90.256%
Average Noise Output (>1450 Load Combinations)
22.66dBA
Average PF (>1450 Load Combinations)
0.991
Efficiency With 10W (≤500W) or 2% (>500W) Load
71.222%
Standby Power Consumption
0.0583W
12V Ripple (Full Load)
42.12mV
5V Ripple (Full Load)
37.17mV
3.3V Ripple (Full Load)
33.75mV
5VSB Ripple (Full Load)
30.71mV
12V Load Regulation
0.38%
5V Load Regulation
0.43%
3.3V Load Regulation
0.94%
5VSB Load Regulation
3.49%
Inrush Current
29.170A
效率評比
PLATINUM
噪音評比
A
Average Efficiency (>1450 load combinations)
92.328%
Average Noise Output (>1450 Load Combinations)
22.95dBA
Average PF (>1450 Load Combinations)
0.970
Efficiency With 10W (≤500W) or 2% (>500W) Load
70.921%
Standby Power Consumption
0.0920W
12V Ripple (Full Load)
46.00mV
5V Ripple (Full Load)
37.47mV
3.3V Ripple (Full Load)
33.70mV
5VSB Ripple (Full Load)
31.86mV
12V Load Regulation
0.38%
5V Load Regulation
0.43%
3.3V Load Regulation
0.94%
5VSB Load Regulation
3.51%
Inrush Current
45.650A
12V Transient Response (200%)
11.49V
5V Transient Response (200%)
4.953V
3.3V Transient Response (200%)
3.163V
5VSB Transient Response (200%)
4.965V
Hold-Up Time & Power Ok Signal
20.50ms
AC Loss to PWR_OK Hold Up Time
17.40ms
PWR_OK Inactive to DC Loss Delay
3.10ms
PSU Timings: T1 (20% / 100%)
59.0ms
59.0ms
PSU Timings: T3 (20% / 100%)
122.0ms
122.0ms
12V OCP (25.0°C / 42.1°C)
109.00A (131.33%), 12.032V
108.20A (130.36%), 12.035V
5V OCP (25.0°C / 42.1°C)
30A (150.00%), 5.07V
29.4A (147.00%), 5.071V
3.3V OCP (25.0°C / 42.1°C)
31A (155.00%), 3.262V
31A (155.00%), 3.259V
5VSB OCP (25.0°C / 42.1°C)
4.2A (140.00%), 5.041V
4.1A (136.67%), 5.037V
OPP (25.22°C / 44.50°C)
131.11%
135.91%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
20.5
AC Loss to PWR_OK Hold Up Time (ms)
17.4
PWR_OK Inactive to DC Loss Delay (ms)
3.1
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.84 V
114.74 V
113.85 V
114.93 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.97 Hz
59.40 Hz
60.03 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.423
1.421
1.340
1.425
1.490
PASS
Mains Voltage THD:
0.15 %
0.11 %
N/A
0.29 %
2.00 %
PASS
Real Power:
0.058 W
0.051 W
N/A
0.066 W
N/A
N/A
Apparent Power:
6.719 W
6.701 W
N/A
6.737 W
N/A
N/A
Power Factor:
0.009
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.87 V
229.75 V
227.70 V
229.98 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.98 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.419
1.417
1.340
1.421
1.490
PASS
Mains Voltage THD:
0.14 %
0.09 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.092 W
0.074 W
N/A
0.113 W
N/A
N/A
Apparent Power:
23.231 W
23.202 W
N/A
23.260 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input