Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
16-22AWG
No
4+4 pin EPS12V (700mm)
2
2
16AWG
No
6+2 pin PCIe (600mm)
3
3
16AWG
No
12+4 pin PCIe (650mm) (600W)
1
1
16-24AWG
No
SATA (455mm+120mm+120mm+120mm)
1
4
18AWG
No
4-pin Molex (450mm+120mm+120mm+120mm)
1
4
18AWG
No
Protection Features(Manufacturer)
Under Voltage Protection
✓
Over Power Protection
✓
Over Current (+12V) Protection
✓
Over Temperature Protection
✓
Short Circuit Protection
✓
Surge Protection
✓
Inrush Current Protection
✓
Power Specifications
Rail
3.3V
5V
12V
5VSB
-12V
Max. Power
Amps
20
20
83
3
0.3
Watts
120
996
15
3.6
Total Max. Power (W)
1000
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-32 / 82.4-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Accredited
Average Efficiency (>1450 load combinations)
90.256%
Average Noise Output (>1450 Load Combinations)
22.66dBA
Average PF (>1450 Load Combinations)
0.991
Efficiency With 10W (≤500W) or 2% (>500W) Load
71.222%
Standby Power Consumption
0.0583W
Non-Accredited
12V Ripple (Full Load)
42.12mV
5V Ripple (Full Load)
37.17mV
3.3V Ripple (Full Load)
33.75mV
5VSB Ripple (Full Load)
30.71mV
12V Load Regulation
0.38%
5V Load Regulation
0.43%
3.3V Load Regulation
0.94%
5VSB Load Regulation
3.49%
Inrush Current
29.170A
Accredited
Average Efficiency (>1450 load combinations)
92.328%
Average Noise Output (>1450 Load Combinations)
22.95dBA
Average PF (>1450 Load Combinations)
0.970
Efficiency With 10W (≤500W) or 2% (>500W) Load
70.921%
Standby Power Consumption
0.0920W
Non-Accredited
12V Ripple (Full Load)
46.00mV
5V Ripple (Full Load)
37.47mV
3.3V Ripple (Full Load)
33.70mV
5VSB Ripple (Full Load)
31.86mV
12V Load Regulation
0.38%
5V Load Regulation
0.43%
3.3V Load Regulation
0.94%
5VSB Load Regulation
3.51%
Inrush Current
45.650A
12V Transient Response (200%)
11.49V
5V Transient Response (200%)
4.953V
3.3V Transient Response (200%)
3.163V
5VSB Transient Response (200%)
4.965V
Hold-Up Time & PWR_OK Signal
20.50ms
AC Loss to PWR_OK Hold Up Time
17.40ms
PWR_OK Inactive to DC Loss Delay
3.10ms
PSU Timings: T1 (20% / 100%)
59.0ms
59.0ms
PSU Timings: T3 (20% / 100%)
122.0ms
122.0ms
12V OCP (25.0°C / 42.1°C)
109.00A (131.33%), 12.032V
108.20A (130.36%), 12.035V
5V OCP (25.0°C / 42.1°C)
30A (150.00%), 5.07V
29.4A (147.00%), 5.071V
3.3V OCP (25.0°C / 42.1°C)
31A (155.00%), 3.262V
31A (155.00%), 3.259V
5VSB OCP (25.0°C / 42.1°C)
4.2A (140.00%), 5.041V
4.1A (136.67%), 5.037V
OPP (25.22°C / 44.50°C)
131.11%
135.91%
Hold-Up Time & PWR_OK Signal
Hold-Up Time (ms)
20.5
AC Loss to PWR_OK Hold Up Time (ms)
17.4
PWR_OK Inactive to DC Loss Delay (ms)
3.1
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.84 V
114.74 V
113.85 V
114.93 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.97 Hz
59.40 Hz
60.03 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.423
1.421
1.340
1.425
1.490
PASS
Mains Voltage THD:
0.15 %
0.11 %
N/A
0.29 %
2.00 %
PASS
Real Power:
0.058 W
0.051 W
N/A
0.066 W
N/A
N/A
Apparent Power:
6.719 W
6.701 W
N/A
6.737 W
N/A
N/A
Power Factor:
0.009
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.87 V
229.75 V
227.70 V
229.98 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.98 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.419
1.417
1.340
1.421
1.490
PASS
Mains Voltage THD:
0.14 %
0.09 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.092 W
0.074 W
N/A
0.113 W
N/A
N/A
Apparent Power:
23.231 W
23.202 W
N/A
23.260 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN 55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC & Bypass Relay
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.498A
1.965A
1.989A
0.975A
99.98
88.686%
859
19.5
40.52°C
0.969
12.062V
5.089V
3.318V
5.127V
112.736
42.28°C
114.81V
20%
14.018A
2.948A
2.986A
1.174A
199.921
91.691%
891
20.4
40.54°C
0.986
12.058V
5.087V
3.315V
5.112V
218.038
44.76°C
114.78V
30%
21.897A
3.441A
3.487A
1.373A
299.968
92.216%
945
22.6
41.37°C
0.989
12.053V
5.086V
3.312V
5.098V
325.291
47.66°C
114.75V
40%
29.739A
3.934A
3.988A
1.574A
399.471
92.179%
999
24.4
41.62°C
0.992
12.047V
5.083V
3.31V
5.083V
433.365
50.83°C
114.72V
50%
37.258A
4.92A
4.991A
1.776A
499.205
91.894%
1087
27.2
42.45°C
0.995
12.043V
5.081V
3.306V
5.068V
543.244
54.19°C
114.68V
60%
44.853A
5.908A
5.995A
1.979A
599.738
91.4%
1149
29
42.58°C
0.996
12.038V
5.078V
3.303V
5.053V
656.167
56.84°C
114.64V
70%
52.385A
6.896A
7.002A
2.184A
699.472
90.827%
1402
34.7
43.1°C
0.997
12.033V
5.076V
3.299V
5.037V
770.121
58.68°C
114.61V
80%
59.992A
7.884A
8.009A
2.289A
799.485
90.146%
1497
36.5
43.85°C
0.997
12.028V
5.073V
3.296V
5.024V
886.874
61.04°C
114.57V
90%
67.940A
8.38A
8.501A
2.394A
899.291
89.435%
1587
38.3
44.56°C
0.998
12.023V
5.071V
3.293V
5.012V
1005.528
64.01°C
114.53V
100%
75.694A
8.876A
9.023A
3.01A
999.319
88.604%
1701
40.2
45.93°C
0.998
12.018V
5.069V
3.291V
4.984V
1127.849
67.18°C
114.5V
110%
83.381A
9.868A
10.128A
3.016A
1099.93
87.653%
1826
42.3
46.76°C
0.998
12.012V
5.067V
3.288V
4.973V
1254.864
70.72°C
114.45V
CL1
0.115A
14.239A
14.496A
0A
121.297
84.848%
1489
36.3
40.85°C
0.976
12.067V
5.071V
3.29V
5.143V
142.959
53.93°C
114.8V
CL2
0.115A
19.696A
0A
0A
101.338
83.606%
1201
30.3
40.19°C
0.971
12.066V
5.075V
3.312V
5.15V
121.208
48.72°C
114.81V
CL3
0.114A
0A
20.068A
0A
67.381
78.209%
1402
34.7
40.96°C
0.959
12.066V
5.086V
3.289V
5.15V
86.157
45.03°C
114.82V
CL4
83.231A
0A
0A
0A
999.886
89.222%
1510
36.9
45.22°C
0.998
12.014V
5.084V
3.31V
5.084V
1120.682
62.79°C
114.51V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.499A
1.965A
1.989A
0.975A
99.985
89.712%
858
19.5
40.62°C
0.901
12.062V
5.088V
3.317V
5.127V
111.448
41.04°C
229.83V
20%
14.019A
2.949A
2.987A
1.174A
199.929
92.897%
900
20.9
40.84°C
0.954
12.057V
5.086V
3.314V
5.112V
215.214
42.01°C
229.81V
30%
21.898A
3.442A
3.487A
1.373A
299.973
93.735%
938
22.3
41.02°C
0.971
12.053V
5.084V
3.312V
5.098V
320.021
42.84°C
229.8V
40%
29.736A
3.935A
3.984A
1.57A
399.418
93.926%
993
24.1
41.62°C
0.978
12.047V
5.082V
3.31V
5.083V
425.245
44.11°C
229.78V
50%
37.258A
4.921A
4.99A
1.776A
499.21
93.883%
1083
27
42.17°C
0.982
12.043V
5.08V
3.306V
5.068V
531.735
45.83°C
229.76V
60%
44.851A
5.91A
5.995A
1.979A
599.74
93.612%
1151
29.1
42.73°C
0.985
12.039V
5.077V
3.303V
5.052V
640.664
47.06°C
229.75V
70%
52.385A
6.898A
7.001A
2.184A
699.473
93.297%
1405
34.7
43.06°C
0.987
12.033V
5.075V
3.3V
5.037V
749.727
48.31°C
229.74V
80%
59.991A
7.886A
8.008A
2.289A
799.482
92.895%
1492
36.5
43.9°C
0.989
12.028V
5.071V
3.296V
5.024V
860.626
49.92°C
229.72V
90%
67.939A
8.382A
8.5A
2.394A
899.301
92.509%
1582
38.1
44.04°C
0.99
12.023V
5.07V
3.294V
5.012V
972.121
51.6°C
229.7V
100%
75.695A
8.879A
9.023A
3.01A
999.332
92.027%
1709
40.4
45.53°C
0.991
12.018V
5.068V
3.291V
4.983V
1085.916
54.17°C
229.68V
110%
83.382A
9.871A
10.127A
3.017A
1099.938
91.509%
1823
42.3
46.37°C
0.991
12.013V
5.065V
3.288V
4.973V
1202.001
56.26°C
229.67V
CL1
0.115A
14.241A
14.494A
0A
121.298
85.594%
1485
36.3
41.13°C
0.926
12.067V
5.07V
3.291V
5.142V
141.713
45.71°C
229.82V
CL2
0.115A
19.699A
0A
0A
101.342
84.553%
1219
30.5
40.76°C
0.91
12.066V
5.074V
3.312V
5.15V
119.854
43.63°C
229.83V
CL3
0.115A
0A
20.065A
0A
67.382
78.809%
1226
30.7
40.2°C
0.865
12.066V
5.086V
3.289V
5.149V
85.501
42.24°C
229.84V
CL4
83.232A
0A
0A
0A
999.902
92.598%
1479
36.3
44.69°C
0.991
12.013V
5.083V
3.31V
5.084V
1079.832
51.8°C
229.68V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.230A
0.491A
0.497A
0.194A
19.993
70.888%
708
12.4
36.24°C
0.87
12.060V
5.091V
3.322V
5.158V
28.204
39.07°C
114.84V
40W
2.710A
0.687A
0.696A
0.291A
39.995
81.21%
739
14.3
37.25°C
0.93
12.063V
5.091V
3.321V
5.154V
49.249
39.14°C
114.82V
60W
4.188A
0.884A
0.894A
0.388A
59.995
85.561%
783
16.2
38.55°C
0.952
12.063V
5.091V
3.32V
5.149V
70.118
40.02°C
114.83V
80W
5.662A
1.08A
1.093A
0.486A
79.931
87.963%
812
17.1
39°C
0.96
12.062V
5.09V
3.319V
5.144V
90.868
41°C
114.81V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.230A
0.491A
0.497A
0.194A
19.993
70.876%
708
12.4
36°C
0.568
12.061V
5.089V
3.322V
5.158V
28.207
36.14°C
229.84V
40W
2.710A
0.688A
0.696A
0.291A
39.995
81.7%
736
14.3
37.02°C
0.741
12.064V
5.089V
3.321V
5.153V
48.955
37.12°C
229.84V
60W
4.188A
0.884A
0.894A
0.388A
59.995
86.104%
767
16
38°C
0.826
12.063V
5.09V
3.32V
5.149V
69.678
38.08°C
229.84V
80W
5.663A
1.08A
1.093A
0.486A
79.933
88.53%
796
17.1
39.09°C
0.873
12.062V
5.089V
3.319V
5.144V
90.289
39.28°C
229.83V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
39.1 mV
35.8 mV
33.5 mV
30.3 mV
Pass
20% Load
37.6 mV
37.1 mV
36.1 mV
31.7 mV
Pass
30% Load
36.9 mV
36.0 mV
32.4 mV
29.9 mV
Pass
40% Load
36.9 mV
37.6 mV
34.5 mV
30.4 mV
Pass
50% Load
38.0 mV
37.5 mV
34.5 mV
30.8 mV
Pass
60% Load
34.2 mV
31.7 mV
30.2 mV
27.3 mV
Pass
70% Load
34.1 mV
33.2 mV
29.7 mV
27.7 mV
Pass
80% Load
36.6 mV
35.7 mV
32.1 mV
28.3 mV
Pass
90% Load
37.0 mV
35.1 mV
31.9 mV
28.5 mV
Pass
100% Load
42.1 mV
37.2 mV
33.8 mV
30.7 mV
Pass
110% Load
43.7 mV
39.6 mV
33.1 mV
30.4 mV
Pass
Crossload 1
40.1 mV
37.2 mV
37.6 mV
39.6 mV
Pass
Crossload 2
36.8 mV
38.1 mV
34.9 mV
38.4 mV
Pass
Crossload 3
36.1 mV
35.7 mV
33.4 mV
39.1 mV
Pass
Crossload 4
43.4 mV
36.7 mV
33.6 mV
39.8 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
35.5 mV
34.1 mV
31.5 mV
28.8 mV
Pass
20% Load
35.7 mV
35.1 mV
32.4 mV
29.0 mV
Pass
30% Load
34.6 mV
33.4 mV
34.1 mV
29.0 mV
Pass
40% Load
35.6 mV
34.5 mV
32.7 mV
29.4 mV
Pass
50% Load
38.4 mV
36.1 mV
34.3 mV
30.8 mV
Pass
60% Load
36.7 mV
34.7 mV
33.4 mV
29.2 mV
Pass
70% Load
36.5 mV
35.8 mV
32.2 mV
29.3 mV
Pass
80% Load
37.6 mV
36.9 mV
34.2 mV
29.9 mV
Pass
90% Load
37.4 mV
35.9 mV
32.7 mV
29.7 mV
Pass
100% Load
46.0 mV
37.5 mV
33.7 mV
31.9 mV
Pass
110% Load
44.4 mV
37.5 mV
34.6 mV
31.1 mV
Pass
Crossload 1
38.0 mV
38.1 mV
35.5 mV
39.9 mV
Pass
Crossload 2
35.6 mV
39.9 mV
35.1 mV
37.7 mV
Pass
Crossload 3
36.5 mV
36.3 mV
33.3 mV
40.2 mV
Pass
Crossload 4
43.2 mV
36.4 mV
31.9 mV
40.6 mV
Pass
The results above are not used in the certification process
Gamer Storm PQ1000P
Top side
Power specifications label
Cybenetics bietet freiwillige Zertifizierungsprogramme für Netzteile – ETA für Effizienz, LAMBDA für Lautstärke und SAFE für Sicherheit und korrekten Betrieb – sowie für Kühlprodukte mit DELTA für die Schalldämmung von Gehäusen und PHI für Luftstrom und statischen Druck von Lüftern