Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (500mm)
1
1
18AWG
No
4+4 pin EPS12V (580mm)
1
1
18AWG
No
6+2 pin PCIe (600mm+125mm)
1
2
16-18AWG
No
SATA (410mm+150mm+150mm)
2
6
18AWG
No
4-pin Molex (400mm+150mm+150mm)
1
3
18AWG
No
Modular Cables
AC Power Cord (1380mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✗
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
GOLD
Lautstärkeklasse
A
Average Efficiency (>1450 load combinations)
87.721%
Average Noise Output (>1450 Load Combinations)
22.82dBA
Average PF (>1450 Load Combinations)
0.977
Efficiency With 10W (≤500W) or 2% (>500W) Load
71.339%
Standby Power Consumption
0.0743W
12V Ripple (Full Load)
73.10mV
5V Ripple (Full Load)
22.02mV
3.3V Ripple (Full Load)
18.33mV
5VSB Ripple (Full Load)
44.44mV
12V Load Regulation
1.42%
5V Load Regulation
2.99%
3.3V Load Regulation
3.44%
5VSB Load Regulation
3.99%
Inrush Current
65.900A
Wirkungsgrad
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
89.325%
Average Noise Output (>1450 Load Combinations)
25.86dBA
Average PF (>1450 Load Combinations)
0.899
Efficiency With 10W (≤500W) or 2% (>500W) Load
73.187%
Standby Power Consumption
0.2015W
12V Ripple (Full Load)
71.21mV
5V Ripple (Full Load)
21.57mV
3.3V Ripple (Full Load)
18.04mV
5VSB Ripple (Full Load)
43.03mV
12V Load Regulation
1.45%
5V Load Regulation
3.01%
3.3V Load Regulation
3.47%
5VSB Load Regulation
4.01%
Inrush Current
132.900A
12V Transient Response (150%)
11.75V
5V Transient Response (150%)
4.967V
3.3V Transient Response (150%)
3.222V
5VSB Transient Response (150%)
4.998V
Hold-Up Time & Power Ok Signal
16.40ms
AC Loss to PWR_OK Hold Up Time
14.40ms
PWR_OK Inactive to DC Loss Delay
2.00ms
PSU Timings: T1 (20% / 100%)
45.0ms
45.0ms
PSU Timings: T3 (20% / 100%)
126.0ms
127.0ms
12V OCP (26.4°C / 43.0°C)
69.00A (150.66%), 11.925V
68.80A (150.22%), 11.948V
5V OCP (26.4°C / 43.0°C)
25.9A (129.50%), 4.967V
25.2A (126.00%), 4.969V
3.3V OCP (26.4°C / 43.0°C)
30A (150.00%), 3.289V
30A (150.00%), 3.287V
5VSB OCP (26.4°C / 43.0°C)
4.2A (140.00%), 5.019V
4.2A (140.00%), 5.002V
OPP (26.28°C / 43.42°C)
150.00%
150.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
16.4
AC Loss to PWR_OK Hold Up Time (ms)
14.4
PWR_OK Inactive to DC Loss Delay (ms)
2
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.07 V
115.04 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.95 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.074 W
0.017 W
N/A
0.103 W
N/A
N/A
Apparent Power:
15.970 W
15.896 W
N/A
16.056 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.03 V
230.93 V
227.70 V
231.10 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.201 W
0.162 W
N/A
0.284 W
N/A
N/A
Apparent Power:
52.685 W
52.427 W
N/A
52.949 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input