Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (500mm)
1
1
18AWG
No
4+4 pin EPS12V (580mm)
1
1
18AWG
No
6+2 pin PCIe (600mm+125mm)
1
2
16-18AWG
No
SATA (410mm+150mm+150mm)
2
6
18AWG
No
4-pin Molex (400mm+150mm+150mm)
1
3
18AWG
No
Modular Cables
AC Power Cord (1380mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✗
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Efficiency Rating
GOLD
Noise Rating
A
Average Efficiency (>1450 load combinations)
87.721%
Average Noise Output (>1450 Load Combinations)
22.82dBA
Average PF (>1450 Load Combinations)
0.977
Efficiency With 10W (≤500W) or 2% (>500W) Load
71.339%
Standby Power Consumption
0.0743W
12V Ripple (Full Load)
73.10mV
5V Ripple (Full Load)
22.02mV
3.3V Ripple (Full Load)
18.33mV
5VSB Ripple (Full Load)
44.44mV
12V Load Regulation
1.42%
5V Load Regulation
2.99%
3.3V Load Regulation
3.44%
5VSB Load Regulation
3.99%
Inrush Current
65.900A
Efficiency Rating
Noise Rating
A-
Average Efficiency (>1450 load combinations)
89.325%
Average Noise Output (>1450 Load Combinations)
25.86dBA
Average PF (>1450 Load Combinations)
0.899
Efficiency With 10W (≤500W) or 2% (>500W) Load
73.187%
Standby Power Consumption
0.2015W
12V Ripple (Full Load)
71.21mV
5V Ripple (Full Load)
21.57mV
3.3V Ripple (Full Load)
18.04mV
5VSB Ripple (Full Load)
43.03mV
12V Load Regulation
1.45%
5V Load Regulation
3.01%
3.3V Load Regulation
3.47%
5VSB Load Regulation
4.01%
Inrush Current
132.900A
12V Transient Response (150%)
11.75V
5V Transient Response (150%)
4.967V
3.3V Transient Response (150%)
3.222V
5VSB Transient Response (150%)
4.998V
Hold-Up Time & Power Ok Signal
16.40ms
AC Loss to PWR_OK Hold Up Time
14.40ms
PWR_OK Inactive to DC Loss Delay
2.00ms
PSU Timings: T1 (20% / 100%)
45.0ms
45.0ms
PSU Timings: T3 (20% / 100%)
126.0ms
127.0ms
12V OCP (26.4°C / 43.0°C)
69.00A (150.66%), 11.925V
68.80A (150.22%), 11.948V
5V OCP (26.4°C / 43.0°C)
25.9A (129.50%), 4.967V
25.2A (126.00%), 4.969V
3.3V OCP (26.4°C / 43.0°C)
30A (150.00%), 3.289V
30A (150.00%), 3.287V
5VSB OCP (26.4°C / 43.0°C)
4.2A (140.00%), 5.019V
4.2A (140.00%), 5.002V
OPP (26.28°C / 43.42°C)
150.00%
150.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
16.4
AC Loss to PWR_OK Hold Up Time (ms)
14.4
PWR_OK Inactive to DC Loss Delay (ms)
2
Vampire Power
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.07 V
115.04 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.95 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.074 W
0.017 W
N/A
0.103 W
N/A
N/A
Apparent Power:
15.970 W
15.896 W
N/A
16.056 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.03 V
230.93 V
227.70 V
231.10 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.201 W
0.162 W
N/A
0.284 W
N/A
N/A
Apparent Power:
52.685 W
52.427 W
N/A
52.949 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted