Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (650mm)
1
1
16-22AWG
No
4+4 pin EPS12V (700mm)
2
2
18AWG
No
6+2 pin PCIe (600mm+155mm)
2
4
18AWG
No
12+4 pin PCIe (610mm) (600W)
1
1
16-24AWG
No
SATA (500mm+150mm+150mm)
1
9
18AWG
No
4-pin Molex (500mm+150mm+150mm)
1
3
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
GOLD
Lautstärkeklasse
Standard++
Average Efficiency (>1450 load combinations)
88.946%
Average Noise Output (>1450 Load Combinations)
31.12dBA
Average PF (>1450 Load Combinations)
0.991
Efficiency With 10W (≤500W) or 2% (>500W) Load
67.499%
Standby Power Consumption
0.0382W
12V Ripple (Full Load)
29.42mV
5V Ripple (Full Load)
31.24mV
3.3V Ripple (Full Load)
30.08mV
5VSB Ripple (Full Load)
50.45mV
12V Load Regulation
0.92%
5V Load Regulation
0.76%
3.3V Load Regulation
1.21%
5VSB Load Regulation
4.28%
Inrush Current
166.300A
Wirkungsgrad
PLATINUM
Lautstärkeklasse
Standard++
Average Efficiency (>1450 load combinations)
91.028%
Average Noise Output (>1450 Load Combinations)
30.38dBA
Average PF (>1450 Load Combinations)
0.965
Efficiency With 10W (≤500W) or 2% (>500W) Load
66.979%
Standby Power Consumption
0.0867W
12V Ripple (Full Load)
28.19mV
5V Ripple (Full Load)
27.83mV
3.3V Ripple (Full Load)
27.36mV
5VSB Ripple (Full Load)
49.41mV
12V Load Regulation
0.90%
5V Load Regulation
0.78%
3.3V Load Regulation
1.27%
5VSB Load Regulation
4.43%
Inrush Current
215.100A
12V Transient Response (200%)
11.46V
5V Transient Response (200%)
4.938V
3.3V Transient Response (200%)
3.239V
5VSB Transient Response (200%)
4.911V
Hold-Up Time & Power Ok Signal
19.70ms
AC Loss to PWR_OK Hold Up Time
16.70ms
PWR_OK Inactive to DC Loss Delay
3.00ms
PSU Timings: T1 (20% / 100%)
39.0ms
40.0ms
PSU Timings: T3 (20% / 100%)
117.0ms
117.0ms
12V OCP (26.2°C / 35.5°C)
90.60A (127.97%), 12.125V
90.00A (127.12%), 12.131V
5V OCP (26.2°C / 35.5°C)
27.3A (136.50%), 4.997V
27A (135.00%), 4.988V
3.3V OCP (26.2°C / 35.5°C)
30.2A (151.00%), 3.276V
29.3A (146.50%), 3.226V
5VSB OCP (26.2°C / 35.5°C)
4.4A (146.67%), 4.934V
4.4A (146.67%), 4.93V
OPP (26.34°C / 41.17°C)
120.90%
114.42%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19.7
AC Loss to PWR_OK Hold Up Time (ms)
16.7
PWR_OK Inactive to DC Loss Delay (ms)
3
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.07 V
115.04 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.038 W
-0.000 W
N/A
0.065 W
N/A
N/A
Apparent Power:
2.374 W
2.302 W
N/A
2.450 W
N/A
N/A
Power Factor:
0.021
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.03 V
230.92 V
227.70 V
231.10 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.28 %
2.00 %
PASS
Real Power:
0.087 W
0.072 W
N/A
0.115 W
N/A
N/A
Apparent Power:
7.964 W
7.848 W
N/A
8.099 W
N/A
N/A
Power Factor:
0.010
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input