66.00A (106.45%), 11.416V* *Didn't shut down, low voltage (11.099V@80A)
64.00A (103.23%), 11.425V* *Didn't shut down, low voltage (11.055V@81A)
5V OCP (25.9°C / 42.2°C)
3.3V OCP (25.9°C / 42.2°C)
27.2A (151.11%), 3.143V* *Didn't shut down, low voltage (3.126V@27.3A)
22A (122.22%), 3.151V* *Didn't shut down, low voltage (2.507V@27.1A)
5VSB OCP (25.9°C / 42.2°C)
4.7A (156.67%), 4.919V
4.3A (143.33%), 4.95V
OPP (27.12°C / 43.60°C)
123.07%
122.67%
保持时间 & PG信号
Hold-Up Time (ms)
11.9
AC Loss to PWR_OK Hold Up Time (ms)
9.1
PWR_OK Inactive to DC Loss Delay (ms)
2.8
待机电源
Tables 230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.05 V
230.93 V
227.70 V
231.10 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.417
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.29 %
2.00 %
PASS
Real Power:
0.107 W
0.065 W
N/A
0.183 W
N/A
N/A
Apparent Power:
21.648 W
21.271 W
N/A
22.045 W
N/A
N/A
Power Factor:
0.006
N/A
N/A
N/A
N/A
N/A
Graphs 230V
转换效率图表
230V
资讯
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
噪音值图表
230V
资讯
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
高环温电源转换效率
资讯
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5Vsb转换效率
资讯
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input