| 115V | 230V | |
| Scheme: ETA-EMI PSU | ![]() |
![]() |
| 115V | 230V | |
![]() |
![]() |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 32.7 °C | 0 RPM · <6.0 dB(A) · 46.4 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 32.7 °C | 0 RPM · <6.0 dB(A) · 46.6 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 33.5 °C | 339 RPM · <6.0 dB(A) · 42.2 °C | <6.0 in both |
| 100% | 1078 RPM · 32.4 dB(A) · 30.2 °C | 1088 RPM · 32.8 dB(A) · 45.5 °C | +0.4 dB(A) |
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 0 RPM · <6.0 dB(A) · 31.4 °C | 0 RPM · <6.0 dB(A) · 43.4 °C | fan off in both |
| 20% | 0 RPM · <6.0 dB(A) · 31.9 °C | 0 RPM · <6.0 dB(A) · 44.4 °C | fan off in both |
| 50% | 0 RPM · <6.0 dB(A) · 33.4 °C | 368 RPM · <6.0 dB(A) · 42.2 °C | <6.0 in both |
| 100% | 1077 RPM · 32.4 dB(A) · 30.2 °C | 1088 RPM · 32.8 dB(A) · 45.4 °C | +0.4 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.