Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
18AWG
No
4+4 pin EPS12V (750mm)
2
2
18AWG
No
6+2 pin PCIe (550mm+150mm)
1
2
18AWG
No
6+2 pin PCIe (550mm)
2
2
18AWG
No
12+4 pin PCIe (610mm) (600W)
1
1
16-26AWG
No
SATA (500mm+150mm+150mm+145mm)
3
12
18AWG
No
4-pin Molex (500mm+150mm+150mm) / FDD (+155mm)
1
3 / 1
18-22AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
89.053%
Average Noise Output (>1450 Load Combinations)
29.99dBA
Average PF (>1450 Load Combinations)
0.988
Efficiency With 10W (≤500W) or 2% (>500W) Load
69.648%
Standby Power Consumption
0.0128W
12V Ripple (Full Load)
39.06mV
5V Ripple (Full Load)
34.40mV
3.3V Ripple (Full Load)
30.06mV
5VSB Ripple (Full Load)
24.92mV
12V Load Regulation
0.91%
5V Load Regulation
2.93%
3.3V Load Regulation
4.13%
5VSB Load Regulation
2.86%
Inrush Current
Too low to detect
Wirkungsgrad
GOLD
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
91.106%
Average Noise Output (>1450 Load Combinations)
29.67dBA
Average PF (>1450 Load Combinations)
0.930
Efficiency With 10W (≤500W) or 2% (>500W) Load
67.059%
Standby Power Consumption
0.0743W
12V Ripple (Full Load)
36.51mV
5V Ripple (Full Load)
32.87mV
3.3V Ripple (Full Load)
29.86mV
5VSB Ripple (Full Load)
25.13mV
12V Load Regulation
0.88%
5V Load Regulation
2.91%
3.3V Load Regulation
4.09%
5VSB Load Regulation
2.82%
Inrush Current
Too low to detect
12V Transient Response (200%)
11.05V
5V Transient Response (200%)
4.929V
3.3V Transient Response (200%)
3.194V
5VSB Transient Response (200%)
4.843V
Hold-Up Time & Power Ok Signal
19.80ms
AC Loss to PWR_OK Hold Up Time
17.40ms
PWR_OK Inactive to DC Loss Delay
2.40ms
PSU Timings: T1 (20% / 100%)
66.0ms
64.0ms
PSU Timings: T3 (20% / 100%)
120.0ms
120.0ms
12V OCP (30.1°C / 43.8°C)
123.40A (148.09%), 11.936V
107.80A (129.37%), 11.947V
5V OCP (30.1°C / 43.8°C)
27.5A (137.50%), 5.002V
27.3A (136.50%), 4.996V
3.3V OCP (30.1°C / 43.8°C)
28.2A (141.00%), 3.269V
28.7A (143.50%), 3.261V
5VSB OCP (30.1°C / 43.8°C)
5A (166.67%), 5.012V
5A (166.67%), 5.012V
OPP (29.13°C / 42.32°C)
144.45%
121.95%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19.8
AC Loss to PWR_OK Hold Up Time (ms)
17.4
PWR_OK Inactive to DC Loss Delay (ms)
2.4
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
114.85 V
114.80 V
113.85 V
114.88 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.98 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.419
1.418
1.340
1.420
1.490
PASS
Mains Voltage THD:
0.14 %
0.11 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.013 W
0.011 W
N/A
0.015 W
N/A
N/A
Apparent Power:
10.307 W
10.283 W
N/A
10.329 W
N/A
N/A
Power Factor:
0.001
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
229.85 V
229.80 V
227.70 V
229.91 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.419
1.418
1.340
1.420
1.490
PASS
Mains Voltage THD:
0.17 %
0.15 %
N/A
0.20 %
2.00 %
PASS
Real Power:
0.074 W
0.037 W
N/A
0.111 W
N/A
N/A
Apparent Power:
34.565 W
34.496 W
N/A
34.608 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input