Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (590mm)
1
1
16-22AWG
No
4+4 pin EPS12V (700mm)
2
2
16AWG
No
6+2 pin PCIe (550mm+150mm)
2
4
16-18AWG
No
12+4 pin PCIe (610mm) (600W)
1
1
16-24AWG
No
SATA (450mm+150mm+150mm)
3
9
18AWG
No
4-pin Molex (450mm+150mm+150mm)
1
3
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
GOLD
Lautstärkeklasse
Standard+
Average Efficiency (>1450 load combinations)
88.434%
Average Noise Output (>1450 Load Combinations)
35.67dBA
Average PF (>1450 Load Combinations)
0.975
Efficiency With 10W (≤500W) or 2% (>500W) Load
70.092%
Standby Power Consumption
0.0350W
12V Ripple (Full Load)
31.41mV
5V Ripple (Full Load)
23.18mV
3.3V Ripple (Full Load)
20.80mV
5VSB Ripple (Full Load)
41.34mV
12V Load Regulation
1.07%
5V Load Regulation
0.90%
3.3V Load Regulation
1.31%
5VSB Load Regulation
3.44%
Inrush Current
23.950A
Wirkungsgrad
GOLD
Lautstärkeklasse
Standard+
Average Efficiency (>1450 load combinations)
90.632%
Average Noise Output (>1450 Load Combinations)
35.64dBA
Average PF (>1450 Load Combinations)
0.958
Efficiency With 10W (≤500W) or 2% (>500W) Load
67.312%
Standby Power Consumption
0.0907W
12V Ripple (Full Load)
28.73mV
5V Ripple (Full Load)
23.80mV
3.3V Ripple (Full Load)
21.53mV
5VSB Ripple (Full Load)
40.51mV
12V Load Regulation
1.07%
5V Load Regulation
0.86%
3.3V Load Regulation
1.28%
5VSB Load Regulation
3.40%
Inrush Current
35.130A
12V Transient Response (200%)
11.28V
5V Transient Response (200%)
4.927V
3.3V Transient Response (200%)
3.141V
5VSB Transient Response (200%)
4.921V
Hold-Up Time & Power Ok Signal
17.90ms
AC Loss to PWR_OK Hold Up Time
14.90ms
PWR_OK Inactive to DC Loss Delay
3.00ms
PSU Timings: T1 (20% / 100%)
38.0ms
37.0ms
PSU Timings: T3 (20% / 100%)
117.0ms
117.0ms
12V OCP (29.7°C / °C)
120.20A (120.20%), 12.064V
5V OCP (29.7°C / °C)
27.3A (136.50%), 4.993V
3.3V OCP (29.7°C / °C)
26.9A (134.50%), 3.306V
5VSB OCP (29.7°C / °C)
4.8A (160.00%), 5.076V
OPP (30.57°C / 0.00°C)
123.15%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
17.9
AC Loss to PWR_OK Hold Up Time (ms)
14.9
PWR_OK Inactive to DC Loss Delay (ms)
3
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.10 V
115.04 V
113.85 V
115.12 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.95 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.20 %
2.00 %
PASS
Real Power:
0.035 W
-0.010 W
N/A
0.075 W
N/A
N/A
Apparent Power:
2.425 W
2.348 W
N/A
2.516 W
N/A
N/A
Power Factor:
0.023
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.05 V
230.94 V
227.70 V
231.11 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.28 %
2.00 %
PASS
Real Power:
0.091 W
0.050 W
N/A
0.181 W
N/A
N/A
Apparent Power:
8.115 W
8.000 W
N/A
8.243 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input