Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (655mm)
1
1
18AWG
No
4+4 pin EPS12V (655mm)
1
1
18AWG
No
8 pin EPS12V (655mm)
1
1
18AWG
No
6+2 pin PCIe (550mm)
3
3
16AWG
No
12+4 pin PCIe (655mm) (600W)
1
1
16-28AWG
No
SATA (510mm+120mm+120mm+120mm)
3
12
18AWG
No
4-pin Molex (500mm+120mm+120mm+120mm)
1
4
18AWG
No
AC Power Cord (1370mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
GOLD
噪音評比
A+
Average Efficiency (>1450 load combinations)
88.843%
Average Noise Output (>1450 Load Combinations)
17.83dBA
Average PF (>1450 Load Combinations)
0.985
Efficiency With 10W (≤500W) or 2% (>500W) Load
73.482%
Standby Power Consumption
0.0391W
12V Ripple (Full Load)
38.22mV
5V Ripple (Full Load)
18.60mV
3.3V Ripple (Full Load)
17.41mV
5VSB Ripple (Full Load)
18.93mV
12V Load Regulation
0.05%
5V Load Regulation
0.44%
3.3V Load Regulation
0.72%
5VSB Load Regulation
2.28%
Inrush Current
Too low to detect
效率評比
PLATINUM
噪音評比
A+
Average Efficiency (>1450 load combinations)
91.415%
Average Noise Output (>1450 Load Combinations)
15.74dBA
Average PF (>1450 Load Combinations)
0.967
Efficiency With 10W (≤500W) or 2% (>500W) Load
74.554%
Standby Power Consumption
0.0927W
12V Ripple (Full Load)
36.80mV
5V Ripple (Full Load)
17.58mV
3.3V Ripple (Full Load)
16.75mV
5VSB Ripple (Full Load)
17.84mV
12V Load Regulation
0.05%
5V Load Regulation
0.46%
3.3V Load Regulation
0.72%
5VSB Load Regulation
2.30%
Inrush Current
Too low to detect
12V Transient Response (200%)
11.11V
5V Transient Response (200%)
4.933V
3.3V Transient Response (200%)
3.182V
5VSB Transient Response (200%)
4.789V
Hold-Up Time & Power Ok Signal
27.50ms
AC Loss to PWR_OK Hold Up Time
24.40ms
PWR_OK Inactive to DC Loss Delay
3.10ms
PSU Timings: T1 (20% / 100%)
65.0ms
64.0ms
PSU Timings: T3 (20% / 100%)
115.0ms
115.0ms
12V OCP (30.0°C / 43.1°C)
121.80A (117.12%), 12.138V
121.80A (117.12%), 12.141V
5V OCP (30.0°C / 43.1°C)
22.9A (114.50%), 5.029V
22.9A (114.50%), 5.014V
3.3V OCP (30.0°C / 43.1°C)
25.4A (127.00%), 3.323V
25.0A (125.00%), 3.317V
5VSB OCP (30.0°C / 43.1°C)
4.2A (140.00%), 5.057V
4.2A (140.00%), 5.05V
OPP (31.23°C / 42.05°C)
126.46%
121.42%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
27.5
AC Loss to PWR_OK Hold Up Time (ms)
24.4
PWR_OK Inactive to DC Loss Delay (ms)
3.1
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.08 V
115.04 V
113.85 V
115.12 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.97 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.20 %
2.00 %
PASS
Real Power:
0.039 W
-0.010 W
N/A
0.083 W
N/A
N/A
Apparent Power:
7.302 W
6.727 W
N/A
7.894 W
N/A
N/A
Power Factor:
0.006
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.04 V
230.93 V
227.70 V
231.10 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.15 %
N/A
0.27 %
2.00 %
PASS
Real Power:
0.093 W
0.052 W
N/A
0.162 W
N/A
N/A
Apparent Power:
21.977 W
21.297 W
N/A
22.712 W
N/A
N/A
Power Factor:
0.003
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input