21A (116.67%), 4.832V* *Voltage Drop (4.369@21.2A)
20.5A (113.89%), 4.878V* *Voltage Drop (4.387@20.7A)
3.3V OCP (28.9°C / 42.7°C)
21.3A (118.33%), 3.175V* *Voltage Drop (2.652@21.6A)
21.1A (117.22%), 3.187V* *Voltage Drop (2.638@21.5A)
5VSB OCP (28.9°C / 42.7°C)
4.1A (164.00%), 4.951V
4A (160.00%), 4.952V
OPP (29.07°C / 40.92°C)
130.93%
116.80%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
17.4
AC Loss to PWR_OK Hold Up Time (ms)
14.4
PWR_OK Inactive to DC Loss Delay (ms)
3
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.17 V
115.14 V
113.85 V
115.18 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.92 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.13 %
0.11 %
N/A
0.15 %
2.00 %
PASS
Real Power:
0.093 W
0.085 W
N/A
0.112 W
N/A
N/A
Apparent Power:
11.929 W
11.925 W
N/A
11.932 W
N/A
N/A
Power Factor:
0.008
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.44 V
230.40 V
227.70 V
230.45 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.14 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.171 W
0.151 W
N/A
0.234 W
N/A
N/A
Apparent Power:
39.878 W
39.867 W
N/A
39.895 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input