Cables and Connectors(Non-accredited measurements)
Captive Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (545mm)
1
1
18-22AWG
No
4+4 pin EPS12V (630mm)
2
2
18AWG
No
6+2 pin PCIe (570mm+150mm)
1
2
18AWG
No
SATA (465mm+120mm+120mm)
1
3
18AWG
No
SATA (460mm+120mm) / 4-pin Molex (+120mm)
1
2 / 1
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
BRONZE
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
84.550%
Average Noise Output (>1450 Load Combinations)
31.12dBA
Average PF (>1450 Load Combinations)
0.976
Efficiency With 10W (≤500W) or 2% (>500W) Load
60.291%
Standby Power Consumption
0.0792W
12V Ripple (Full Load)
49.28mV
5V Ripple (Full Load)
39.04mV
3.3V Ripple (Full Load)
24.78mV
5VSB Ripple (Full Load)
30.63mV
12V Load Regulation
0.61%
5V Load Regulation
1.44%
3.3V Load Regulation
4.04%
5VSB Load Regulation
3.80%
Inrush Current
32.950A
效率評比
SILVER
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
87.305%
Average Noise Output (>1450 Load Combinations)
30.64dBA
Average PF (>1450 Load Combinations)
0.941
Efficiency With 10W (≤500W) or 2% (>500W) Load
-%
Standby Power Consumption
0.1649W
12V Ripple (Full Load)
48.66mV
5V Ripple (Full Load)
36.76mV
3.3V Ripple (Full Load)
24.72mV
5VSB Ripple (Full Load)
25.92mV
12V Load Regulation
0.59%
5V Load Regulation
1.52%
3.3V Load Regulation
4.07%
5VSB Load Regulation
3.80%
Inrush Current
65.690A
12V Transient Response (150%)
11.85V
5V Transient Response (150%)
4.955V
3.3V Transient Response (150%)
3.210V
5VSB Transient Response (150%)
4.944V
Hold-Up Time & Power Ok Signal
15.40ms
AC Loss to PWR_OK Hold Up Time
14.00ms
PWR_OK Inactive to DC Loss Delay
1.40ms
PSU Timings: T1 (20% / 100%)
28.0ms
28.0ms
PSU Timings: T3 (20% / 100%)
123.0ms
122.0ms
12V OCP (30.4°C / 43.3°C)
72.60A (134.20%), 12.186V
63.80A (117.93%), 12.189V
5V OCP (30.4°C / 43.3°C)
22.3A (123.89%), 5.066V
20.9A (116.11%), 5.081V
3.3V OCP (30.4°C / 43.3°C)
21.5A (119.44%), 3.323V
20.4A (113.33%), 3.32V
5VSB OCP (30.4°C / 43.3°C)
4.7A (156.67%), 4.96V
4.6A (153.33%), 4.969V
OPP (31.58°C / 43.94°C)
132.65%
115.31%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
15.4
AC Loss to PWR_OK Hold Up Time (ms)
14
PWR_OK Inactive to DC Loss Delay (ms)
1.4
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.06 V
115.03 V
113.85 V
115.10 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.94 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.079 W
0.005 W
N/A
0.118 W
N/A
N/A
Apparent Power:
7.670 W
7.437 W
N/A
7.943 W
N/A
N/A
Power Factor:
0.010
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.02 V
230.92 V
227.70 V
231.09 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.15 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.165 W
0.123 W
N/A
0.231 W
N/A
N/A
Apparent Power:
25.297 W
24.945 W
N/A
25.676 W
N/A
N/A
Power Factor:
0.006
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input