Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (605mm)
1
1
16-22AWG
No
4+4 pin EPS12V (650mm)
1
1
16AWG
No
8 pin EPS12V (650mm)
1
1
16AWG
No
6+2 pin PCIe (600mm+160mm)
1
2
16-18AWG
No
6+2 pin PCIe (600mm)
2
2
16AWG
No
12+2 pin PCIe (650mm) (600W)
1
1
16-24AWG
No
SATA (405mm+150mm+150mm+150mm)
3
12
18AWG
No
4-pin Molex (405mm+105mm+105mm+105mm)
1
4
18AWG
No
AC Power Cord (1850mm) - C13 coupler
1
1
14AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
GOLD
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
88.107%
Average Noise Output (>1450 Load Combinations)
27.37dBA
Average PF (>1450 Load Combinations)
0.994
Efficiency With 10W (≤500W) or 2% (>500W) Load
70.250%
Standby Power Consumption
0.0610W
12V Ripple (Full Load)
21.17mV
5V Ripple (Full Load)
19.17mV
3.3V Ripple (Full Load)
20.61mV
5VSB Ripple (Full Load)
17.11mV
12V Load Regulation
1.47%
5V Load Regulation
0.70%
3.3V Load Regulation
0.67%
5VSB Load Regulation
3.02%
Inrush Current
34.900A
Wirkungsgrad
GOLD
Lautstärkeklasse
A-
Average Efficiency (>1450 load combinations)
90.195%
Average Noise Output (>1450 Load Combinations)
27.03dBA
Average PF (>1450 Load Combinations)
0.965
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1371W
12V Ripple (Full Load)
20.26mV
5V Ripple (Full Load)
19.67mV
3.3V Ripple (Full Load)
20.12mV
5VSB Ripple (Full Load)
16.24mV
12V Load Regulation
1.47%
5V Load Regulation
0.70%
3.3V Load Regulation
0.67%
5VSB Load Regulation
3.04%
Inrush Current
66.800A
12V Transient Response (200%)
11.34V
5V Transient Response (200%)
4.938V
3.3V Transient Response (200%)
3.207V
5VSB Transient Response (200%)
4.988V
Hold-Up Time & Power Ok Signal
18.00ms
AC Loss to PWR_OK Hold Up Time
15.00ms
PWR_OK Inactive to DC Loss Delay
3.00ms
PSU Timings: T1 (20% / 100%)
109.0ms
54.0ms
PSU Timings: T3 (20% / 100%)
124.0ms
124.0ms
12V OCP (30.8°C / 41.6°C)
90.00A (127.12%), 11.839V
90.20A (127.40%), 11.844V
5V OCP (30.8°C / 41.6°C)
28.3A (141.50%), 4.997V
27.6A (138.00%), 4.995V
3.3V OCP (30.8°C / 41.6°C)
28.5A (142.50%), 3.289V
27.6A (138.00%), 3.288V
5VSB OCP (30.8°C / 41.6°C)
5.4A (180.00%), 4.995V
5.2A (173.33%), 4.99V
OPP (31.05°C / 42.25°C)
123.85%
123.85%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
18
AC Loss to PWR_OK Hold Up Time (ms)
15
PWR_OK Inactive to DC Loss Delay (ms)
3
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.07 V
115.03 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.95 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.061 W
0.019 W
N/A
0.099 W
N/A
N/A
Apparent Power:
7.049 W
6.938 W
N/A
7.141 W
N/A
N/A
Power Factor:
0.010
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.01 V
230.93 V
227.70 V
231.08 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.24 %
2.00 %
PASS
Real Power:
0.137 W
0.097 W
N/A
0.199 W
N/A
N/A
Apparent Power:
23.973 W
23.715 W
N/A
24.233 W
N/A
N/A
Power Factor:
0.005
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input