Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (650mm)
1
1
16-22AWG
No
4+4 pin EPS12V (650mm)
1
1
16AWG
No
8 pin EPS12V (650mm)
1
1
16AWG
No
6+2 pin PCIe (550mm)
5
5
18AWG
No
12+4 pin PCIe (650mm) (600W)
1
1
16-28AWG
No
SATA (510mm+115mm+115mm+115mm)
4
16
18AWG
No
4-pin Molex (510mm+120mm+120mm+120mm)
1
4
18AWG
No
AC Power Cord (1380mm) - C13 coupler
1
1
17AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A
Average Efficiency (>1450 load combinations)
90.089%
Average Noise Output (>1450 Load Combinations)
20.10dBA
Average PF (>1450 Load Combinations)
0.987
Efficiency With 10W (≤500W) or 2% (>500W) Load
66.693%
Standby Power Consumption
0.0262W
12V Ripple (Full Load)
40.27mV
5V Ripple (Full Load)
8.42mV
3.3V Ripple (Full Load)
13.30mV
5VSB Ripple (Full Load)
9.08mV
12V Load Regulation
1.26%
5V Load Regulation
1.72%
3.3V Load Regulation
3.18%
5VSB Load Regulation
4.04%
Inrush Current
Too low to detect
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A+
Average Efficiency (>1450 load combinations)
92.454%
Average Noise Output (>1450 Load Combinations)
19.34dBA
Average PF (>1450 Load Combinations)
0.939
Efficiency With 10W (≤500W) or 2% (>500W) Load
67.598%
Standby Power Consumption
0.1473W
12V Ripple (Full Load)
40.71mV
5V Ripple (Full Load)
8.80mV
3.3V Ripple (Full Load)
13.82mV
5VSB Ripple (Full Load)
9.76mV
12V Load Regulation
1.29%
5V Load Regulation
1.74%
3.3V Load Regulation
3.21%
5VSB Load Regulation
4.04%
Inrush Current
Too low to detect
12V Transient Response (200%)
11.25V
5V Transient Response (200%)
4.973V
3.3V Transient Response (200%)
3.136V
5VSB Transient Response (200%)
4.920V
Hold-Up Time & Power Ok Signal
23.00ms
AC Loss to PWR_OK Hold Up Time
20.80ms
PWR_OK Inactive to DC Loss Delay
2.20ms
PSU Timings: T1 (20% / 100%)
66.0ms
35.0ms
PSU Timings: T3 (20% / 100%)
114.0ms
113.0ms
12V OCP (30.4°C / 44.0°C)
141.80A (130.93%), 12.032V
140.64A (129.86%), 12.034V
5V OCP (30.4°C / 44.0°C)
25.4A (127.00%), 5.033V
24.6A (123.00%), 5.036V
3.3V OCP (30.4°C / 44.0°C)
26.6A (133.00%), 3.296V
25.9A (129.50%), 3.297V
5VSB OCP (30.4°C / 44.0°C)
5.6A (186.67%), 4.997V
5.2A (173.33%), 5V
OPP (31.62°C / 44.13°C)
129.20%
129.21%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
23
AC Loss to PWR_OK Hold Up Time (ms)
20.8
PWR_OK Inactive to DC Loss Delay (ms)
2.2
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.07 V
115.05 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
60.00 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.10 %
N/A
0.17 %
2.00 %
PASS
Real Power:
0.026 W
0.009 W
N/A
0.045 W
N/A
N/A
Apparent Power:
23.854 W
23.756 W
N/A
23.947 W
N/A
N/A
Power Factor:
0.001
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.03 V
230.95 V
227.70 V
231.10 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.17 %
0.15 %
N/A
0.25 %
2.00 %
PASS
Real Power:
0.147 W
0.110 W
N/A
0.205 W
N/A
N/A
Apparent Power:
80.937 W
80.576 W
N/A
81.253 W
N/A
N/A
Power Factor:
0.002
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input