Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
18-20AWG
No
4+4 pin EPS12V (700mm+150mm)
2
4
18AWG
No
6+2 pin PCIe (700mm)
3
3
18AWG
No
12+4 pin PCIe (700mm) (600W)
1
1
16-28AWG
No
SATA (500mm+150mm+150mm+150mm)
2
8
18AWG
No
4-pin Molex (500mm+150mm+150mm+150mm)
2
8
18AWG
No
FDD Adapter (+105mm)
1
1
22AWG
No
AC Power Cord (1385mm) - C13 coupler
1
1
17AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
90.042%
Average Noise Output (>1450 Load Combinations)
30.20dBA
Average PF (>1450 Load Combinations)
0.994
Efficiency With 10W (≤500W) or 2% (>500W) Load
74.495%
Standby Power Consumption
0.0353W
12V Ripple (Full Load)
33.36mV
5V Ripple (Full Load)
30.19mV
3.3V Ripple (Full Load)
27.30mV
5VSB Ripple (Full Load)
10.33mV
12V Load Regulation
0.32%
5V Load Regulation
0.54%
3.3V Load Regulation
1.15%
5VSB Load Regulation
3.28%
Inrush Current
33.480A
效率評比
PLATINUM
噪音評比
A-
Average Efficiency (>1450 load combinations)
92.241%
Average Noise Output (>1450 Load Combinations)
29.57dBA
Average PF (>1450 Load Combinations)
0.971
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1085W
12V Ripple (Full Load)
20.83mV
5V Ripple (Full Load)
29.85mV
3.3V Ripple (Full Load)
26.39mV
5VSB Ripple (Full Load)
9.78mV
12V Load Regulation
0.32%
5V Load Regulation
0.52%
3.3V Load Regulation
1.12%
5VSB Load Regulation
3.30%
Inrush Current
70.580A
12V Transient Response (200%)
11.16V
5V Transient Response (200%)
4.879V
3.3V Transient Response (200%)
3.135V
5VSB Transient Response (200%)
4.993V
Hold-Up Time & Power Ok Signal
23.70ms
AC Loss to PWR_OK Hold Up Time
18.50ms
PWR_OK Inactive to DC Loss Delay
5.20ms
PSU Timings: T1 (20% / 100%)
102.0ms
100.0ms
PSU Timings: T3 (20% / 100%)
122.0ms
122.0ms
12V OCP (32.1°C / 44.5°C)
126.80A (144.91%), 12.041V
121.60A (138.97%), 12.041V
5V OCP (32.1°C / 44.5°C)
34.7A (173.50%), 4.946V
34.8A (174.00%), 4.948V
3.3V OCP (32.1°C / 44.5°C)
31.4A (157.00%), 3.299V
32.5A (162.50%), 3.299V
5VSB OCP (32.1°C / 44.5°C)
4.3A (172.00%), 5.021V
4.3A (172.00%), 5.016V
OPP (32.03°C / 42.57°C)
141.29%
131.39%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
23.7
AC Loss to PWR_OK Hold Up Time (ms)
18.5
PWR_OK Inactive to DC Loss Delay (ms)
5.2
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.07 V
115.03 V
113.85 V
115.11 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.08 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.035 W
-0.012 W
N/A
0.071 W
N/A
N/A
Apparent Power:
8.683 W
8.425 W
N/A
8.948 W
N/A
N/A
Power Factor:
0.005
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.01 V
230.91 V
227.70 V
231.08 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.109 W
0.067 W
N/A
0.185 W
N/A
N/A
Apparent Power:
28.562 W
28.187 W
N/A
28.962 W
N/A
N/A
Power Factor:
0.005
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input