Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (620mm)
1
1
18-22AWG
No
4+4 pin EPS12V (700mm)
2
2
18AWG
No
6+2 pin PCIe (750mm)
3
3
18AWG
No
12+4 pin PCIe (650mm) (600W)
1
1
16-24AWG
No
SATA (415mm+120mm+120mm+120mm)
2
8
18AWG
No
4-pin Molex (410mm+155mm+100mm)
1
3
18AWG
No
AC Power Cord (1350mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
GOLD
Lautstärkeklasse
A+
Average Efficiency (>1450 load combinations)
88.676%
Average Noise Output (>1450 Load Combinations)
19.09dBA
Average PF (>1450 Load Combinations)
0.984
Efficiency With 10W (≤500W) or 2% (>500W) Load
61.966%
Standby Power Consumption
0.0424W
12V Ripple (Full Load)
40.24mV
5V Ripple (Full Load)
17.79mV
3.3V Ripple (Full Load)
18.49mV
5VSB Ripple (Full Load)
18.60mV
12V Load Regulation
0.08%
5V Load Regulation
0.60%
3.3V Load Regulation
0.64%
5VSB Load Regulation
2.43%
Inrush Current
67.300A
Wirkungsgrad
GOLD
Lautstärkeklasse
A+
Average Efficiency (>1450 load combinations)
90.666%
Average Noise Output (>1450 Load Combinations)
17.97dBA
Average PF (>1450 Load Combinations)
0.948
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1107W
12V Ripple (Full Load)
38.48mV
5V Ripple (Full Load)
15.76mV
3.3V Ripple (Full Load)
17.58mV
5VSB Ripple (Full Load)
16.91mV
12V Load Regulation
0.05%
5V Load Regulation
0.58%
3.3V Load Regulation
0.61%
5VSB Load Regulation
2.43%
Inrush Current
116.000A
12V Transient Response (200%)
11.46V
5V Transient Response (200%)
4.952V
3.3V Transient Response (200%)
3.218V
5VSB Transient Response (200%)
4.938V
Hold-Up Time & Power Ok Signal
21.00ms
AC Loss to PWR_OK Hold Up Time
17.30ms
PWR_OK Inactive to DC Loss Delay
3.70ms
PSU Timings: T1 (20% / 100%)
50.0ms
49.0ms
PSU Timings: T3 (20% / 100%)
139.0ms
139.0ms
12V OCP (28.8°C / 42.3°C)
71.60A (114.56%), 12.008V
71.60A (114.56%), 12.028V
5V OCP (28.8°C / 42.3°C)
23.7A (118.50%), 4.984V
23.5A (117.50%), 4.977V
3.3V OCP (28.8°C / 42.3°C)
24A (120.00%), 3.281V
23.2A (116.00%), 3.277V
5VSB OCP (28.8°C / 42.3°C)
4.5A (150.00%), 5.012V
4.5A (150.00%), 5.008V
OPP (29.31°C / 42.13°C)
128.09%
122.63%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
21
AC Loss to PWR_OK Hold Up Time (ms)
17.3
PWR_OK Inactive to DC Loss Delay (ms)
3.7
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.06 V
115.02 V
113.85 V
115.10 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.14 %
0.10 %
N/A
0.20 %
2.00 %
PASS
Real Power:
0.042 W
-0.002 W
N/A
0.082 W
N/A
N/A
Apparent Power:
6.488 W
6.226 W
N/A
6.761 W
N/A
N/A
Power Factor:
0.007
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.01 V
230.90 V
227.70 V
231.09 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.28 %
2.00 %
PASS
Real Power:
0.111 W
0.071 W
N/A
0.176 W
N/A
N/A
Apparent Power:
20.699 W
20.287 W
N/A
21.103 W
N/A
N/A
Power Factor:
0.005
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input