Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (600mm)
1
1
18-20AWG
No
8 pin EPS12V (700mm) / 4+4 pin EPS12V (+150mm)
2
4
18AWG
No
6+2 pin PCIe (700mm)
3
3
16AWG
No
12+2 pin PCIe (700mm) (600W)
1
1
16-24AWG
No
SATA (500mm+150mm+150mm+150mm)
2
8
18AWG
No
SATA (500mm+150mm) / 4-pin Molex (+150mm+150mm)
2
4 / 4
18AWG
No
FDD Adapter (+105mm)
1
1
22AWG
No
AC Power Cord (1410mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A++
Average Efficiency (>1450 load combinations)
89.950%
Average Noise Output (>1450 Load Combinations)
7.65dBA
Average PF (>1450 Load Combinations)
0.993
Efficiency With 10W (≤500W) or 2% (>500W) Load
71.390%
Standby Power Consumption
0.0872W
12V Ripple (Full Load)
44.92mV
5V Ripple (Full Load)
19.82mV
3.3V Ripple (Full Load)
24.31mV
5VSB Ripple (Full Load)
35.26mV
12V Load Regulation
0.23%
5V Load Regulation
0.80%
3.3V Load Regulation
0.78%
5VSB Load Regulation
2.94%
Inrush Current
185.300A
Wirkungsgrad
GOLD
Lautstärkeklasse
A++
Average Efficiency (>1450 load combinations)
91.855%
Average Noise Output (>1450 Load Combinations)
7.25dBA
Average PF (>1450 Load Combinations)
0.967
Efficiency With 10W (≤500W) or 2% (>500W) Load
72.719%
Standby Power Consumption
0.1863W
12V Ripple (Full Load)
28.79mV
5V Ripple (Full Load)
20.32mV
3.3V Ripple (Full Load)
25.91mV
5VSB Ripple (Full Load)
35.66mV
12V Load Regulation
0.23%
5V Load Regulation
0.80%
3.3V Load Regulation
0.81%
5VSB Load Regulation
2.96%
Inrush Current
194.700A
12V Transient Response (200%)
11.17V
5V Transient Response (200%)
4.890V
3.3V Transient Response (200%)
3.194V
5VSB Transient Response (200%)
4.971V
Hold-Up Time & Power Ok Signal
25.40ms
AC Loss to PWR_OK Hold Up Time
21.80ms
PWR_OK Inactive to DC Loss Delay
3.60ms
PSU Timings: T1 (20% / 100%)
102.0ms
101.0ms
PSU Timings: T3 (20% / 100%)
122.0ms
121.0ms
12V OCP (26.3°C / 41.7°C)
106.40A (127.73%), 11.973V
103.00A (123.65%), 11.976V
5V OCP (26.3°C / 41.7°C)
32.5A (162.50%), 4.952V
32A (160.00%), 4.946V
3.3V OCP (26.3°C / 41.7°C)
31.5A (157.50%), 3.331V
32A (160.00%), 3.329V
5VSB OCP (26.3°C / 41.7°C)
3.8A (126.67%), 5.035V
3.8A (126.67%), 5.032V
OPP (26.58°C / 41.90°C)
124.21%
122.21%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
25.4
AC Loss to PWR_OK Hold Up Time (ms)
21.8
PWR_OK Inactive to DC Loss Delay (ms)
3.6
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.06 V
115.02 V
113.85 V
115.10 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.08 %
N/A
0.21 %
2.00 %
PASS
Real Power:
0.087 W
0.064 W
N/A
0.115 W
N/A
N/A
Apparent Power:
7.077 W
6.885 W
N/A
7.280 W
N/A
N/A
Power Factor:
0.013
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.00 V
230.90 V
227.70 V
231.06 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.28 %
2.00 %
PASS
Real Power:
0.186 W
0.140 W
N/A
0.341 W
N/A
N/A
Apparent Power:
23.489 W
23.208 W
N/A
23.782 W
N/A
N/A
Power Factor:
0.007
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input