Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 24 pin (600mm)
1
1
16-22AWG
No
4+4 pin EPS12V (650mm)
2
2
16AWG
No
6+2 pin PCIe (675mm+150mm)
2
4
16-18AWG
No
6+2 pin PCIe (670mm)
1
1
16-18AWG
No
12+4 pin PCIe (700mm) (600W)
1
1
16-24AWG
No
SATA (455mm+105mm+105mm)
3
9
18AWG
No
4-pin Molex (455mm+105mm+105mm)
1
3
18AWG
No
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
Wirkungsgrad
GOLD
Lautstärkeklasse
A
Average Efficiency (>1450 load combinations)
88.981%
Average Noise Output (>1450 Load Combinations)
20.51dBA
Average PF (>1450 Load Combinations)
0.983
Efficiency With 10W (≤500W) or 2% (>500W) Load
64.852%
Standby Power Consumption
0.0526W
12V Ripple (Full Load)
35.85mV
5V Ripple (Full Load)
20.12mV
3.3V Ripple (Full Load)
20.25mV
5VSB Ripple (Full Load)
16.41mV
12V Load Regulation
0.47%
5V Load Regulation
0.67%
3.3V Load Regulation
0.79%
5VSB Load Regulation
1.92%
Inrush Current
61.940A
Wirkungsgrad
PLATINUM
Lautstärkeklasse
A
Average Efficiency (>1450 load combinations)
91.264%
Average Noise Output (>1450 Load Combinations)
20.54dBA
Average PF (>1450 Load Combinations)
0.950
Efficiency With 10W (≤500W) or 2% (>500W) Load
65.465%
Standby Power Consumption
0.1247W
12V Ripple (Full Load)
35.23mV
5V Ripple (Full Load)
21.83mV
3.3V Ripple (Full Load)
25.15mV
5VSB Ripple (Full Load)
16.56mV
12V Load Regulation
0.48%
5V Load Regulation
0.58%
3.3V Load Regulation
0.73%
5VSB Load Regulation
1.94%
Inrush Current
101.000A
12V Transient Response (200%)
11.47V
5V Transient Response (200%)
4.888V
3.3V Transient Response (200%)
3.174V
5VSB Transient Response (200%)
4.882V
Hold-Up Time & Power Ok Signal
17.30ms
AC Loss to PWR_OK Hold Up Time
11.80ms
PWR_OK Inactive to DC Loss Delay
5.50ms
PSU Timings: T1 (20% / 100%)
66.0ms
67.0ms
PSU Timings: T3 (20% / 100%)
125.0ms
122.0ms
12V OCP (28.6°C / 42.6°C)
94.20A (113.09%), 11.970V
93.00A (111.64%), 11.983V
5V OCP (28.6°C / 42.6°C)
29.1A (145.50%), 4.953V
27.4A (137.00%), 4.947V
3.3V OCP (28.6°C / 42.6°C)
29.5A (147.50%), 3.274V
27.1A (135.50%), 3.27V
5VSB OCP (28.6°C / 42.6°C)
5.2A (173.33%), 4.971V
5.2A (173.33%), 4.972V
OPP (28.57°C / 42.86°C)
126.17%
120.97%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
17.3
AC Loss to PWR_OK Hold Up Time (ms)
11.8
PWR_OK Inactive to DC Loss Delay (ms)
5.5
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.04 V
115.01 V
113.85 V
115.09 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.053 W
-0.003 W
N/A
0.104 W
N/A
N/A
Apparent Power:
10.129 W
10.083 W
N/A
10.187 W
N/A
N/A
Power Factor:
0.007
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.00 V
230.90 V
227.70 V
231.06 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.125 W
0.073 W
N/A
0.218 W
N/A
N/A
Apparent Power:
34.839 W
34.644 W
N/A
35.067 W
N/A
N/A
Power Factor:
0.005
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input