Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
In Cable Capacitors
ATX connector 20+4 pin (625mm)
1
1
16-22AWG
No
4+4 pin EPS12V (745mm)
1
1
16AWG
No
8 pin EPS12V (745mm)
1
1
16AWG
No
6+2 pin PCIe (645mm)
2
2
16AWG
No
6+2 pin PCIe (645mm+100mm)
1
2
16AWG
No
12+4 pin PCIe (650mm) (600W)
1
1
16-26AWG
No
2x SATA (380mm+150mm)
1
4
16AWG
No
SATA (310mm+15mm+15mm+15mm)
1
4
16AWG
No
SATA (400mm+150mm+150mm+150mm)
1
4
16AWG
No
4-pin Molex (495mm+150mm+150mm+150mm)
1
4
16AWG
No
AC Power Cord (1390mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
Performance Summary
效率評比
GOLD
噪音評比
A++
Average Efficiency (>1450 load combinations)
88.271%
Average Noise Output (>1450 Load Combinations)
14.27dBA
Average PF (>1450 Load Combinations)
0.990
Efficiency With 10W (≤500W) or 2% (>500W) Load
64.197%
Standby Power Consumption
0.0478W
12V Ripple (Full Load)
30.65mV
5V Ripple (Full Load)
12.60mV
3.3V Ripple (Full Load)
12.46mV
5VSB Ripple (Full Load)
9.23mV
12V Load Regulation
0.09%
5V Load Regulation
0.59%
3.3V Load Regulation
1.09%
5VSB Load Regulation
2.79%
Inrush Current
11.280A
效率評比
GOLD
噪音評比
A++
Average Efficiency (>1450 load combinations)
90.757%
Average Noise Output (>1450 Load Combinations)
13.38dBA
Average PF (>1450 Load Combinations)
0.966
Efficiency With 10W (≤500W) or 2% (>500W) Load
64.653%
Standby Power Consumption
0.0883W
12V Ripple (Full Load)
31.70mV
5V Ripple (Full Load)
12.16mV
3.3V Ripple (Full Load)
12.31mV
5VSB Ripple (Full Load)
8.99mV
12V Load Regulation
0.14%
5V Load Regulation
0.61%
3.3V Load Regulation
1.09%
5VSB Load Regulation
2.79%
Inrush Current
21.550A
12V Transient Response (200%)
11.46V
5V Transient Response (200%)
4.989V
3.3V Transient Response (200%)
3.202V
5VSB Transient Response (200%)
5.001V
Hold-Up Time & Power Ok Signal
17.20ms
AC Loss to PWR_OK Hold Up Time
14.00ms
PWR_OK Inactive to DC Loss Delay
3.20ms
PSU Timings: T1 (20% / 100%)
70.0ms
71.0ms
PSU Timings: T3 (20% / 100%)
126.0ms
124.0ms
OPP (30.16°C / 0.00°C)
134.76%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
17.2
AC Loss to PWR_OK Hold Up Time (ms)
14
PWR_OK Inactive to DC Loss Delay (ms)
3.2
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.06 V
115.02 V
113.85 V
115.09 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.08 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.048 W
-0.005 W
N/A
0.076 W
N/A
N/A
Apparent Power:
6.710 W
6.484 W
N/A
6.955 W
N/A
N/A
Power Factor:
0.010
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.01 V
230.92 V
227.70 V
231.07 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.15 %
N/A
0.26 %
2.00 %
PASS
Real Power:
0.088 W
0.055 W
N/A
0.157 W
N/A
N/A
Apparent Power:
22.186 W
21.885 W
N/A
22.502 W
N/A
N/A
Power Factor:
0.005
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
66.27%
0.049
5.165V
0.35W
114.88V
2
0.09A
0.465W
73.821%
0.088
5.163V
0.63W
114.88V
3
0.55A
2.833W
81.525%
0.348
5.153V
3.475W
114.88V
4
1A
5.142W
81.319%
0.456
5.142V
6.323W
114.87V
5
1.5A
7.696W
81.333%
0.511
5.131V
9.462W
114.87V
6
3A
15.288W
78.739%
0.566
5.096V
19.416W
114.87V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.232W
59.669%
0.016
5.165V
0.389W
229.95V
2
0.09A
0.465W
67.015%
0.028
5.163V
0.694W
229.97V
3
0.55A
2.833W
79.885%
0.138
5.153V
3.547W
229.95V
4
1A
5.142W
80.768%
0.226
5.142V
6.366W
229.95V
5
1.5A
7.696W
81.58%
0.298
5.131V
9.433W
229.95V
6
3A
15.287W
79.987%
0.398
5.096V
19.112W
229.95V
Protection Features
OCP (Normal @ -°C)
-
OCP (Hot @ -°C)
-
OPP (Normal @ 30.2°C)
1010.68W (134.76%)
OPP (Hot @ -°C)
-
OTP
-
SCP
-
PWR_OK
Proper Operation
NLO
✓
Fan Failure Protection
✗
SIP
Surge: None Inrush: None
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
4.404A
1.961A
1.978A
0.974A
74.997
85.746%
704
8.8
40.19°C
0.967
12.126V
5.098V
3.336V
5.134V
87.466
44.85°C
114.85V
20%
9.814A
2.945A
2.972A
1.171A
149.924
89.244%
758
11.2
40.7°C
0.985
12.128V
5.094V
3.331V
5.122V
167.996
45.53°C
114.82V
30%
15.574A
3.437A
3.471A
1.37A
224.923
90.169%
856
14.8
41.44°C
0.987
12.128V
5.092V
3.327V
5.11V
249.445
47.22°C
114.8V
40%
21.341A
3.93A
3.971A
1.569A
300.008
90.388%
947
18.1
41.82°C
0.991
12.127V
5.089V
3.324V
5.099V
331.91
48.76°C
114.77V
50%
26.712A
4.916A
4.97A
1.77A
374.395
90.12%
1041
21
42.42°C
0.993
12.125V
5.086V
3.32V
5.086V
415.443
50.51°C
114.75V
60%
32.128A
5.904A
5.971A
1.971A
449.326
89.71%
1179
24.7
42.85°C
0.994
12.124V
5.082V
3.316V
5.074V
500.868
51.73°C
114.72V
70%
37.550A
6.892A
6.974A
2.173A
524.278
89.134%
1365
29.2
43.12°C
0.995
12.122V
5.079V
3.312V
5.061V
588.194
53.05°C
114.7V
80%
43.034A
7.88A
7.979A
2.277A
599.48
88.479%
1471
31.3
43.69°C
0.996
12.121V
5.076V
3.308V
5.05V
677.542
54.35°C
114.66V
90%
48.851A
8.377A
8.471A
2.381A
674.495
87.812%
1559
33.1
44.29°C
0.996
12.119V
5.073V
3.305V
5.041V
768.111
55.82°C
114.64V
100%
54.474A
8.874A
8.994A
2.989A
749.723
86.966%
1685
35.4
45.77°C
0.996
12.117V
5.071V
3.302V
5.019V
862.092
58.15°C
114.6V
110%
59.960A
9.866A
10.095A
2.994A
824.744
86.027%
1768
36.6
46.37°C
0.997
12.116V
5.068V
3.298V
5.01V
958.704
60.57°C
114.57V
CL1
0.114A
14.231A
14.388A
0A
121.29
82.258%
1036
20.9
40.1°C
0.983
12.132V
5.073V
3.315V
5.132V
147.45
44.73°C
114.83V
CL2
0.114A
19.729A
0A
0A
101.383
81.094%
1006
19.7
40.8°C
0.978
12.135V
5.069V
3.337V
5.145V
125.02
44.48°C
114.85V
CL3
0.114A
0A
19.934A
0A
67.378
75.359%
1007
19.7
40.11°C
0.969
12.132V
5.098V
3.311V
5.14V
89.411
43.1°C
114.86V
CL4
61.872A
0A
0A
0A
749.56
87.894%
1624
34.3
45.78°C
0.996
12.115V
5.087V
3.316V
5.104V
852.805
58.36°C
114.61V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
4.402A
1.963A
1.98A
0.974A
75.005
86.685%
682
8.1
40.22°C
0.867
12.131V
5.096V
3.333V
5.133V
86.527
42.09°C
229.94V
20%
9.814A
2.946A
2.973A
1.172A
149.94
90.844%
750
11.1
40.86°C
0.942
12.129V
5.093V
3.33V
5.121V
165.053
43.5°C
229.92V
30%
15.575A
3.438A
3.472A
1.37A
224.943
92.105%
841
14.5
41.38°C
0.964
12.128V
5.09V
3.327V
5.11V
244.225
44.7°C
229.91V
40%
21.345A
3.931A
3.971A
1.569A
300.031
92.518%
931
17.7
41.93°C
0.974
12.126V
5.088V
3.324V
5.098V
324.292
45.95°C
229.9V
50%
26.720A
4.917A
4.97A
1.77A
374.454
92.503%
1028
20.6
42.02°C
0.979
12.124V
5.085V
3.32V
5.085V
404.803
46.89°C
229.89V
60%
32.136A
5.905A
5.971A
1.971A
449.374
92.35%
1173
24.6
42.62°C
0.982
12.122V
5.082V
3.316V
5.073V
486.599
47.79°C
229.88V
70%
37.556A
6.894A
6.975A
2.174A
524.312
92.06%
1302
27.7
43.08°C
0.985
12.121V
5.078V
3.312V
5.06V
569.532
48.52°C
229.86V
80%
43.044A
7.882A
7.98A
2.277A
599.499
91.712%
1447
30.9
43.81°C
0.987
12.118V
5.075V
3.308V
5.05V
653.679
49.45°C
229.85V
90%
48.861A
8.378A
8.471A
2.381A
674.505
91.388%
1543
32.7
44.68°C
0.988
12.116V
5.072V
3.305V
5.04V
738.067
50.65°C
229.84V
100%
54.479A
8.875A
8.994A
2.989A
749.723
90.906%
1678
35.2
45.85°C
0.989
12.115V
5.07V
3.302V
5.018V
824.728
52.13°C
229.83V
110%
59.970A
9.868A
10.096A
2.994A
824.739
90.382%
1770
36.7
46.16°C
0.989
12.114V
5.067V
3.298V
5.01V
912.506
52.94°C
229.81V
CL1
0.115A
14.232A
14.388A
0A
121.291
83.609%
1098
22.7
40.08°C
0.932
12.135V
5.073V
3.315V
5.132V
145.069
43.72°C
229.94V
CL2
0.114A
19.73A
0A
0A
101.386
82.569%
1045
21.3
41.42°C
0.916
12.137V
5.068V
3.337V
5.145V
122.788
44.02°C
229.94V
CL3
0.114A
0A
19.934A
0A
67.381
76.262%
1067
21.7
41.34°C
0.871
12.133V
5.098V
3.311V
5.14V
88.354
43.37°C
229.94V
CL4
61.878A
0A
0A
0A
749.534
91.816%
1579
33.5
45.74°C
0.989
12.113V
5.087V
3.316V
5.104V
816.349
51.48°C
229.83V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.224A
0.49A
0.494A
0.194A
19.99
70.457%
0
<6.0
45°C
0.874
12.116V
5.101V
3.338V
5.159V
28.371
36.5°C
114.88V
40W
2.696A
0.686A
0.692A
0.291A
39.992
80.538%
0
<6.0
45.87°C
0.936
12.119V
5.101V
3.338V
5.155V
49.656
37.4°C
114.87V
60W
4.168A
0.882A
0.89A
0.388A
59.992
84.204%
0
<6.0
45.87°C
0.959
12.121V
5.1V
3.337V
5.151V
71.247
38.42°C
114.86V
80W
5.634A
1.078A
1.088A
0.486A
79.93
86.943%
0
<6.0
49.4°C
0.97
12.123V
5.1V
3.337V
5.146V
91.934
39.18°C
114.85V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.225A
0.49A
0.494A
0.194A
19.999
70.506%
0
<6.0
42.14°C
0.574
12.123V
5.101V
3.338V
5.158V
28.366
36.28°C
229.95V
40W
2.696A
0.686A
0.692A
0.291A
39.999
81.534%
0
<6.0
44.22°C
0.741
12.125V
5.101V
3.338V
5.154V
49.059
37.88°C
229.94V
60W
4.166A
0.882A
0.89A
0.388A
60
85.809%
0
<6.0
46.04°C
0.826
12.126V
5.1V
3.337V
5.15V
69.924
38.78°C
229.94V
80W
5.632A
1.079A
1.088A
0.486A
79.948
87.913%
648
6.3
39.46°C
0.875
12.130V
5.097V
3.335V
5.146V
90.935
41.81°C
229.93V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.5 mV
8.4 mV
8.6 mV
5.6 mV
Pass
20% Load
13.3 mV
7.7 mV
9.0 mV
6.2 mV
Pass
30% Load
14.3 mV
8.3 mV
9.1 mV
5.8 mV
Pass
40% Load
14.6 mV
7.9 mV
8.9 mV
5.7 mV
Pass
50% Load
14.5 mV
8.4 mV
9.1 mV
6.1 mV
Pass
60% Load
16.0 mV
8.9 mV
9.1 mV
6.1 mV
Pass
70% Load
16.8 mV
9.5 mV
9.3 mV
6.7 mV
Pass
80% Load
18.7 mV
10.3 mV
10.9 mV
7.1 mV
Pass
90% Load
19.8 mV
10.8 mV
11.6 mV
7.1 mV
Pass
100% Load
30.7 mV
12.6 mV
12.5 mV
9.2 mV
Pass
110% Load
32.6 mV
12.9 mV
12.3 mV
10.0 mV
Pass
Crossload 1
19.3 mV
12.2 mV
13.3 mV
16.5 mV
Pass
Crossload 2
12.6 mV
11.8 mV
10.8 mV
14.0 mV
Pass
Crossload 3
12.2 mV
8.6 mV
11.9 mV
13.7 mV
Pass
Crossload 4
30.7 mV
9.8 mV
8.9 mV
16.2 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.4 mV
7.1 mV
8.4 mV
5.6 mV
Pass
20% Load
13.1 mV
7.4 mV
9.0 mV
5.6 mV
Pass
30% Load
13.9 mV
7.7 mV
9.3 mV
5.5 mV
Pass
40% Load
14.5 mV
7.8 mV
8.5 mV
5.8 mV
Pass
50% Load
15.6 mV
8.3 mV
8.6 mV
6.2 mV
Pass
60% Load
15.9 mV
8.7 mV
9.8 mV
5.9 mV
Pass
70% Load
16.8 mV
8.9 mV
9.4 mV
6.7 mV
Pass
80% Load
17.8 mV
10.5 mV
10.7 mV
6.7 mV
Pass
90% Load
18.9 mV
10.7 mV
10.8 mV
7.3 mV
Pass
100% Load
31.7 mV
12.2 mV
12.3 mV
9.0 mV
Pass
110% Load
33.5 mV
12.8 mV
12.4 mV
9.9 mV
Pass
Crossload 1
18.6 mV
11.8 mV
14.0 mV
16.0 mV
Pass
Crossload 2
12.7 mV
11.6 mV
10.3 mV
14.0 mV
Pass
Crossload 3
12.1 mV
8.4 mV
11.8 mV
13.5 mV
Pass
Crossload 4
32.8 mV
10.0 mV
8.7 mV
15.7 mV
Pass
The results above are not used in the certification process