Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
Cable Type
ATX connector 24 pin (350mm)
1
1
16AWG
Tinned Copper
4+4 pin ATX12V (475mm)
1
1
16AWG
Tinned Copper
2x 6+2 pin PCIe (475mm)
2
2
16-18AWG
Tinned Copper
6+2 pin PCIe (475mm)
1
1
16-18AWG
Tinned Copper
12+4 pin PCIe (475mm) (600W)
1
1
16-24AWG
Tinned Copper
SATA (105mm+100mm+150mm)
2
6
18AWG
Tinned Copper
4-pin Molex (105mm+100mm+100mm)
1
3
18AWG
Tinned Copper
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
A-
Average Efficiency (>1450 load combinations)
89.887%
Average Noise Output (>1450 Load Combinations)
25.29dBA
Average PF (>1450 Load Combinations)
0.989
Efficiency With 10W (≤500W) or 2% (>500W) Load
74.457%
Standby Power Consumption
0.0299W
12V Ripple (Full Load)
29.46mV
5V Ripple (Full Load)
18.36mV
3.3V Ripple (Full Load)
17.42mV
5VSB Ripple (Full Load)
37.59mV
12V Load Regulation
0.29%
5V Load Regulation
0.18%
3.3V Load Regulation
0.66%
5VSB Load Regulation
2.94%
Inrush Current
47.940A
效率評比
PLATINUM
噪音評比
A-
Average Efficiency (>1450 load combinations)
91.826%
Average Noise Output (>1450 Load Combinations)
25.39dBA
Average PF (>1450 Load Combinations)
0.964
Efficiency With 10W (≤500W) or 2% (>500W) Load
74.385%
Standby Power Consumption
0.0770W
12V Ripple (Full Load)
30.05mV
5V Ripple (Full Load)
18.09mV
3.3V Ripple (Full Load)
17.29mV
5VSB Ripple (Full Load)
28.62mV
12V Load Regulation
0.35%
5V Load Regulation
0.22%
3.3V Load Regulation
0.69%
5VSB Load Regulation
2.90%
Inrush Current
15.420A
12V Transient Response (200%)
11.52V
5V Transient Response (200%)
4.991V
3.3V Transient Response (200%)
3.271V
5VSB Transient Response (200%)
4.938V
Hold-Up Time & Power Ok Signal
19.90ms
AC Loss to PWR_OK Hold Up Time
16.80ms
PWR_OK Inactive to DC Loss Delay
3.10ms
PSU Timings: T1 (20% / 100%)
58.0ms
57.0ms
PSU Timings: T3 (20% / 100%)
126.0ms
126.0ms
12V OCP (29.2°C / 42.9°C)
89.40A (126.22%), 11.970V
89.40A (126.22%), 11.997V
5V OCP (29.2°C / 42.9°C)
25.1A (125.50%), 5.084V
24.8A (124.00%), 5.084V
3.3V OCP (29.2°C / 42.9°C)
25.8A (129.00%), 3.337V
25.7A (128.50%), 3.336V
5VSB OCP (29.2°C / 42.9°C)
4.5A (150.00%), 4.955V
4.4A (146.67%), 4.953V
OPP (29.85°C / 43.89°C)
123.84%
123.84%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19.9
AC Loss to PWR_OK Hold Up Time (ms)
16.8
PWR_OK Inactive to DC Loss Delay (ms)
3.1
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.09 V
115.03 V
113.85 V
115.13 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.93 Hz
59.40 Hz
60.02 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.418
1.490
PASS
Mains Voltage THD:
0.13 %
0.09 %
N/A
0.18 %
2.00 %
PASS
Real Power:
0.030 W
-0.003 W
N/A
0.063 W
N/A
N/A
Apparent Power:
7.574 W
7.358 W
N/A
7.792 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
231.04 V
230.94 V
227.70 V
231.11 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
49.99 Hz
49.50 Hz
50.01 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.417
1.416
1.340
1.419
1.490
PASS
Mains Voltage THD:
0.17 %
0.14 %
N/A
0.25 %
2.00 %
PASS
Real Power:
0.077 W
0.039 W
N/A
0.138 W
N/A
N/A
Apparent Power:
25.322 W
25.007 W
N/A
25.645 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input