This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
UVP (Full Load @ 90V)
✓
UVP (No Damage @ 80V)
✓
Conducted Emissions EN55032 & CISPR 32
✓
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC & Bypass Relay
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
6.402A
1.989A
2.012A
0.982A
99.998
88.872%
596
12.9
40.1°C
0.832
12.245V
5.028V
3.28V
5.094V
112.531
42.92°C
230.08V
20%
13.818A
2.984A
3.02A
1.181A
199.95
92.317%
600
13.1
40.59°C
0.954
12.233V
5.026V
3.278V
5.082V
216.594
40.62°C
230.06V
30%
21.597A
3.483A
3.525A
1.381A
300.003
93.175%
603
13.3
41.15°C
0.973
12.222V
5.025V
3.277V
5.07V
321.974
42.07°C
230.05V
40%
29.352A
3.981A
4.029A
1.582A
399.598
93.464%
606
13.5
41.57°C
0.98
12.210V
5.024V
3.276V
5.059V
427.543
43.06°C
230.04V
50%
36.793A
4.978A
5.039A
1.784A
499.292
93.337%
619
14.4
42.32°C
0.983
12.197V
5.022V
3.275V
5.046V
534.922
45.69°C
230.02V
60%
44.323A
5.976A
6.05A
1.987A
599.818
93.128%
744
20.9
42.66°C
0.985
12.184V
5.021V
3.273V
5.034V
644.085
48.18°C
230.01V
70%
51.803A
6.974A
7.063A
2.191A
699.559
92.714%
922
28
43.2°C
0.986
12.170V
5.019V
3.271V
5.021V
754.536
49.42°C
229.99V
80%
59.360A
7.971A
8.076A
2.295A
799.565
92.28%
1072
32.5
43.73°C
0.987
12.157V
5.017V
3.269V
5.01V
866.465
50.1°C
229.97V
90%
67.261A
8.471A
8.57A
2.4A
899.358
91.824%
1212
35.9
44.64°C
0.988
12.145V
5.016V
3.267V
5V
979.439
52.4°C
229.95V
100%
74.985A
8.972A
9.095A
3.013A
999.358
91.253%
1313
38
45.1°C
0.988
12.132V
5.015V
3.266V
4.978V
1095.14
54.69°C
229.93V
110%
82.665A
10.024A
10.204A
3.019A
1099.982
90.598%
1393
39.4
46.79°C
0.988
12.117V
4.988V
3.264V
4.968V
1214.135
57.66°C
229.9V
CL1
0.115A
11.993A
12.143A
0A
101.299
83.702%
682
18.1
41.37°C
0.842
12.230V
5.018V
3.27V
5.104V
121.061
50.39°C
230.06V
CL2
0.114A
19.912A
0A
0A
101.345
82.912%
661
16.9
41.72°C
0.844
12.234V
5.019V
3.278V
5.107V
122.26
48.24°C
230.06V
CL3
0.113A
0A
20.206A
0A
67.398
76.785%
620
14.4
41.34°C
0.806
12.236V
5.026V
3.267V
5.107V
87.832
46.36°C
230.06V
CL4
82.357A
0A
0A
0A
999.938
91.993%
1280
37.4
45.32°C
0.988
12.141V
5.026V
3.278V
5.049V
1086.974
52.53°C
229.92V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.212A
0.497A
0.503A
0.196A
20.008
69.147%
585
12.5
36.09°C
0.54
12.255V
5.029V
3.282V
5.116V
28.918
37.9°C
230.04V
40W
2.668A
0.696A
0.704A
0.293A
40.004
80.732%
587
12.7
37.6°C
0.699
12.253V
5.029V
3.281V
5.113V
49.555
38.67°C
230.05V
60W
4.124A
0.895A
0.905A
0.391A
60
85.418%
588
12.7
38.65°C
0.78
12.250V
5.029V
3.281V
5.109V
70.244
39.89°C
230.07V
80W
5.578A
1.094A
1.106A
0.49A
79.947
87.892%
591
12.7
39.32°C
0.807
12.248V
5.029V
3.281V
5.106V
90.963
40.82°C
230.08V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
16.01mV
11.14mV
10.59mV
9.11mV
Pass
20% Load
18.06mV
11.29mV
11.10mV
9.21mV
Pass
30% Load
19.24mV
12.21mV
11.71mV
9.77mV
Pass
40% Load
22.36mV
12.41mV
12.63mV
10.39mV
Pass
50% Load
24.96mV
13.44mV
13.15mV
11.56mV
Pass
60% Load
27.99mV
13.13mV
13.61mV
12.38mV
Pass
70% Load
30.64mV
13.64mV
14.94mV
12.94mV
Pass
80% Load
31.98mV
15.17mV
18.37mV
13.71mV
Pass
90% Load
36.43mV
21.87mV
36.06mV
16.68mV
Pass
100% Load
37.24mV
16.92mV
19.46mV
16.53mV
Pass
110% Load
42.40mV
16.70mV
19.53mV
17.28mV
Pass
Crossload1
16.64mV
11.83mV
13.76mV
9.09mV
Pass
Crossload2
17.40mV
18.04mV
10.85mV
8.90mV
Pass
Crossload3
15.81mV
11.55mV
17.04mV
8.95mV
Pass
Crossload4
37.37mV
14.74mV
15.87mV
13.54mV
Pass
The results above are not used in the certification process
Modecom Volcano HEX 1000W
Top side
Power specifications label
Fan
PSU Internals
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted