Globe Fan S0921512HB (92mm, 12V, 0.45A, Fluid Dynamic Bearing Fan)
5VSB Circuit
Rectifier (High Side)
First Semiconductor FIR4N70L (700V, 2.5A @ 100°C, Rds(on) 3.0mOhm)
Standby PWM Controller
INFSitronix IN2P070C
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
89.780%
Average Noise Output (>1450 Load Combinations)
32.07dBA
Average PF (>1450 Load Combinations)
0.990
Efficiency With 10W (≤500W) or 2% (>500W) Load
72.588%
Standby Power Consumption
0.0851W
12V Ripple (Full Load)
43.97mV
5V Ripple (Full Load)
24.31mV
3.3V Ripple (Full Load)
23.24mV
5VSB Ripple (Full Load)
18.87mV
12V Load Regulation
0.62%
5V Load Regulation
0.69%
3.3V Load Regulation
1.13%
5VSB Load Regulation
2.92%
Inrush Current
56.940A
效率評比
PLATINUM
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
91.767%
Average Noise Output (>1450 Load Combinations)
30.57dBA
Average PF (>1450 Load Combinations)
0.949
Efficiency With 10W (≤500W) or 2% (>500W) Load
74.480%
Standby Power Consumption
0.1528W
12V Ripple (Full Load)
46.54mV
5V Ripple (Full Load)
22.98mV
3.3V Ripple (Full Load)
23.90mV
5VSB Ripple (Full Load)
17.88mV
12V Load Regulation
0.61%
5V Load Regulation
0.67%
3.3V Load Regulation
1.13%
5VSB Load Regulation
2.92%
Inrush Current
79.590A
12V Transient Response (200%)
11.55V
5V Transient Response (200%)
4.926V
3.3V Transient Response (200%)
3.199V
5VSB Transient Response (200%)
4.950V
Hold-Up Time & Power Ok Signal
14.90ms
AC Loss to PWR_OK Hold Up Time
13.50ms
PWR_OK Inactive to DC Loss Delay
1.40ms
PSU Timings: T1 (20% / 100%)
105.0ms
105.0ms
PSU Timings: T3 (20% / 100%)
120.0ms
123.0ms
12V OCP (27.3°C / 44.5°C)
102.60A (144.92%), 11.987V
88.60A (125.14%), 12.017V
5V OCP (27.3°C / 44.5°C)
25.6A (128.00%), 4.988V
20.9A (104.50%), 4.995V
3.3V OCP (27.3°C / 44.5°C)
28.2A (141.00%), 3.294V
24.7A (123.50%), 3.296V
5VSB OCP (27.3°C / 44.5°C)
4.8A (160.00%), 4.791V* High Ripple (>200mV)
4.7A (156.67%), 4.863V* High Ripple (>200mV)
OPP (29.81°C / 43.19°C)
142.67%
125.60%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
14.9
AC Loss to PWR_OK Hold Up Time (ms)
13.5
PWR_OK Inactive to DC Loss Delay (ms)
1.4
待機電源消耗
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.00 V
114.97 V
113.85 V
115.01 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.92 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.416
1.340
1.417
1.490
PASS
Mains Voltage THD:
0.14 %
0.09 %
N/A
0.19 %
2.00 %
PASS
Real Power:
0.085 W
0.056 W
N/A
0.132 W
N/A
N/A
Apparent Power:
11.398 W
11.379 W
N/A
11.418 W
N/A
N/A
Power Factor:
0.007
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.00 V
229.98 V
227.70 V
230.02 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.15 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.153 W
0.097 W
N/A
0.304 W
N/A
N/A
Apparent Power:
37.462 W
37.425 W
N/A
37.503 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input