Cables and Connectors(Non-accredited measurements)
Modular Cables
Description
Cable Count
Connector Count (Total)
Gauge
Cable Type
ATX connector 24 pin (590mm)
1
1
16-20AWG
Tinned Copper
4+4 pin EPS12V (700mm)
2
2
16AWG
Tinned Copper
6+2 pin PCIe (700mm)
6
6
16AWG
Tinned Copper
12+4 pin PCIe (700mm) (600W)
2
2
16-26AWG
Tinned Copper
SATA (550mm+110mm+110mm+110mm)
4
16
18AWG
Tinned Copper
4-pin Molex (550mm+100mm+100mm+100mm)
1
4
18AWG
Tinned Copper
AC Power Cord (1660mm) - C19 coupler
1
1
16AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
ATX v3.1 PSU Power Excursion
✓
Performance Summary 230V
Efficiency Rating
TITANIUM
Noise Rating
Standard++
Average Efficiency (>1450 load combinations)
93.637%
Average Noise Output (>1450 Load Combinations)
30.45dBA
Average PF (>1450 Load Combinations)
0.942
Efficiency With 10W (≤500W) or 2% (>500W) Load
76.201%
Standby Power Consumption
0.1234W
12V Ripple (Full Load)
27.87mV
5V Ripple (Full Load)
17.67mV
3.3V Ripple (Full Load)
17.21mV
5VSB Ripple (Full Load)
15.98mV
12V Load Regulation
0.45%
5V Load Regulation
0.14%
3.3V Load Regulation
0.33%
5VSB Load Regulation
2.29%
Inrush Current
68.510A
12V Transient Response (200%)
11.70V
5V Transient Response (200%)
4.986V
3.3V Transient Response (200%)
3.261V
5VSB Transient Response (200%)
4.998V
Hold-Up Time & Power Ok Signal
31.10ms
AC Loss to PWR_OK Hold Up Time
25.40ms
PWR_OK Inactive to DC Loss Delay
5.70ms
PSU Timings: T1 (20% / 100%)
99.0ms
100.0ms
PSU Timings: T3 (20% / 100%)
122.0ms
122.0ms
12V OCP (29.5°C / 44.3°C)
201.20A (134.22%), 11.982V
200.40A (133.69%), 11.974V
5V OCP (29.5°C / 44.3°C)
31.4A (157.00%), 5.036V
30.7A (153.50%), 5.035V
3.3V OCP (29.5°C / 44.3°C)
28.6A (143.00%), 3.322V
26.9A (134.50%), 3.327V
5VSB OCP (29.5°C / 44.3°C)
5A (166.67%), 4.986V
4.7A (156.67%), 5.008V
OPP (29.21°C / 45.48°C)
129.60%
129.60%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
31.1
AC Loss to PWR_OK Hold Up Time (ms)
25.4
PWR_OK Inactive to DC Loss Delay (ms)
5.7
Vampire Power
Tables 230V
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.02 V
230.00 V
227.70 V
230.10 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.15 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.123 W
0.038 W
N/A
0.184 W
N/A
N/A
Apparent Power:
56.267 W
56.211 W
N/A
56.322 W
N/A
N/A
Power Factor:
0.002
N/A
N/A
N/A
N/A
N/A
Graphs 230V
Efficiency Graph
230V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
230V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
12V to Earth: ✓ 5V to Earth: ✓ 3.3V to Earth: ✓ 5VSB to Earth: ✓ -12V to Earth: ✓
PWR_OK
Proper Operation
UVP (Full Load @ 180V)
✓
UVP (No Damage @ 170V)
✓
Conducted Emissions EN55032 & CISPR 32
✓
NLO
✓
Fan Failure Protection
✗
SIP
Surge: MOV Inrush: NTC & Bypass Relay
Supplementary Tests (For Reference)
Typical Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
10%
13.154A
1.988A
1.995A
0.987A
179.994
91.803%
0
<6.0
45.45°C
0.711
12.042V
5.029V
3.308V
5.068V
196.065
40.33°C
229.86V
20%
27.310A
2.983A
2.993A
1.187A
359.598
94.348%
0
<6.0
49.55°C
0.902
12.036V
5.029V
3.307V
5.057V
381.137
40.52°C
229.83V
30%
41.834A
3.48A
3.493A
1.387A
539.181
94.977%
474
8.9
41.27°C
0.938
12.027V
5.029V
3.307V
5.047V
567.691
43.92°C
229.8V
40%
56.446A
3.977A
3.993A
1.588A
719.594
95.061%
805
25.8
41.91°C
0.961
12.018V
5.028V
3.306V
5.037V
756.977
44.39°C
229.77V
50%
70.670A
4.973A
4.994A
1.79A
899.288
94.94%
1065
33.7
42.16°C
0.973
12.011V
5.027V
3.304V
5.029V
947.215
44.04°C
229.74V
60%
84.928A
5.969A
5.996A
1.993A
1079.743
94.784%
1241
38.4
42.69°C
0.979
12.009V
5.026V
3.302V
5.018V
1139.166
49.98°C
229.7V
70%
99.138A
6.965A
6.998A
2.197A
1259.559
94.314%
1662
46.7
43.36°C
0.984
12.008V
5.025V
3.301V
5.007V
1335.503
51.27°C
229.67V
80%
113.441A
7.96A
7.999A
2.301A
1439.559
93.901%
1828
48.2
43.77°C
0.985
12.003V
5.024V
3.3V
4.998V
1533.07
52.15°C
229.64V
90%
128.069A
8.459A
8.487A
2.405A
1619.404
93.501%
1991
50.2
44.82°C
0.986
12.001V
5.024V
3.299V
4.99V
1731.96
53.65°C
229.62V
100%
142.481A
8.958A
9.005A
3.016A
1799.403
93.134%
2131
51.9
45.87°C
0.987
11.999V
5.023V
3.298V
4.974V
1932.057
55.54°C
229.58V
110%
156.861A
9.954A
10.099A
3.02A
1979.997
92.788%
2163
52
46.27°C
0.988
11.996V
5.023V
3.297V
4.967V
2133.893
57.89°C
229.54V
CL1
0.117A
11.976A
12.007A
0A
101.308
80.115%
1282
40
42.48°C
0.806
12.043V
5.027V
3.306V
5.085V
126.483
52.51°C
229.86V
CL2
0.116A
19.865A
0A
0A
101.341
81.58%
927
29.5
42.99°C
0.804
12.044V
5.031V
3.3V
5.086V
124.225
50.38°C
229.86V
CL3
0.115A
0A
19.894A
0A
67.383
76.868%
624
17.1
42.77°C
0.743
12.047V
5.03V
3.317V
5.086V
87.664
48.96°C
229.87V
CL4
150.109A
0A
0A
0A
1799.937
93.554%
2001
50.3
44.31°C
0.987
11.990V
5.03V
3.303V
5.031V
1923.963
53.06°C
229.59V
The results above are not used in the certification process
Light Load Tests 230V
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
20W
1.232A
0.497A
0.499A
0.197A
19.994
66.423%
0
<6.0
43.33°C
0.414
12.053V
5.03V
3.308V
5.088V
30.105
36°C
229.89V
40W
2.712A
0.696A
0.698A
0.295A
39.997
77.187%
0
<6.0
46.23°C
0.602
12.051V
5.03V
3.309V
5.085V
51.82
37.1°C
229.88V
60W
4.194A
0.894A
0.897A
0.394A
59.997
82.712%
0
<6.0
45.43°C
0.698
12.050V
5.03V
3.309V
5.082V
72.538
38.23°C
229.88V
80W
5.670A
1.093A
1.097A
0.492A
79.939
85.895%
0
<6.0
46.86°C
0.754
12.048V
5.029V
3.309V
5.08V
93.064
39.18°C
229.87V
The results above are not used in the certification process
Ripple Measurements 230V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
24.40mV
19.04mV
17.04mV
12.41mV
Pass
20% Load
25.72mV
21.71mV
19.65mV
11.95mV
Pass
30% Load
29.00mV
21.09mV
19.29mV
12.21mV
Pass
40% Load
29.41mV
20.07mV
18.37mV
12.57mV
Pass
50% Load
26.70mV
19.71mV
18.06mV
12.31mV
Pass
60% Load
26.29mV
19.04mV
17.50mV
18.37mV
Pass
70% Load
25.27mV
19.30mV
18.67mV
14.32mV
Pass
80% Load
25.62mV
18.94mV
17.60mV
14.37mV
Pass
90% Load
25.88mV
19.09mV
17.29mV
20.52mV
Pass
100% Load
27.87mV
17.67mV
17.21mV
15.98mV
Pass
110% Load
27.16mV
19.27mV
18.34mV
15.98mV
Pass
Crossload1
27.56mV
18.87mV
18.80mV
23.11mV
Pass
Crossload2
30.94mV
23.40mV
18.93mV
24.68mV
Pass
Crossload3
23.68mV
19.40mV
18.26mV
24.58mV
Pass
Crossload4
26.08mV
19.04mV
18.17mV
16.55mV
Pass
The results above are not used in the certification process
Super Flower Leadex ATX3+ 1800W
Top side
Power specifications label
Fan
PSU
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted