4.9A (122.50%), 4.888V* Voltage Drop (2.471V @ 5.6A)
4.9A (122.50%), 4.882V* Voltage Drop (2.476V @ 5.6A)
OPP (25.82°C / 42.40°C)
124.41%
119.56%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
28.3
AC Loss to PWR_OK Hold Up Time (ms)
23.3
PWR_OK Inactive to DC Loss Delay (ms)
5
Stromverbrauch im Ruhezustand
Tables
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
115.01 V
114.97 V
113.85 V
115.07 V
116.15 V
PASS
Mains Frequency:
60.00 Hz
59.99 Hz
59.40 Hz
60.01 Hz
60.60 Hz
PASS
Mains Voltage CF:
1.416
1.415
1.340
1.417
1.490
PASS
Mains Voltage THD:
0.13 %
0.10 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.064 W
0.042 W
N/A
0.084 W
N/A
N/A
Apparent Power:
10.389 W
10.367 W
N/A
10.411 W
N/A
N/A
Power Factor:
0.006
N/A
N/A
N/A
N/A
N/A
Detailed Results
Average
Min
Limit Min
Max
Limit Max
Result
Mains Voltage RMS:
230.02 V
229.97 V
227.70 V
230.15 V
232.30 V
PASS
Mains Frequency:
50.00 Hz
50.00 Hz
49.50 Hz
50.00 Hz
50.50 Hz
PASS
Mains Voltage CF:
1.415
1.415
1.340
1.416
1.490
PASS
Mains Voltage THD:
0.14 %
0.13 %
N/A
0.16 %
2.00 %
PASS
Real Power:
0.151 W
0.099 W
N/A
0.408 W
N/A
N/A
Apparent Power:
32.867 W
32.819 W
N/A
32.949 W
N/A
N/A
Power Factor:
0.004
N/A
N/A
N/A
N/A
N/A
Graphs
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Conducted Emissions EN55032 & CISPR 32
NEUTRAL
PHASE
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input